If a valve is continuously energized for long periods, heat generation of the coil may result in reduced performance and shorter service life. This may also have an adverse effect on the peripheral equipment in proximity.

Leaks may result when the supplied pressure exceeds 0.2 MPa(G). When adjusting the pressure on the supply side with a regulator, etc., please take precautions against rising pressure to prevent leakage from the regulator. 3.

Therefore, if an air compressor has a low air delivery, the pressure may not be sufficient. Auto Drain Caution The auto-drain may not function properly, depending on the quality of compressed air. Check its operation once a day. Cleaning of Ventilation Area Caution Remove dust from the ventilation area once a month using a vacuum cleaner or an air blow nozzle. 14-18-12

When forced to mount with an incorrect size terminal, it may result in causing a fire. Air Supply Warning 1. Do not operate with anything other than compressed air. The cleaning equipment has been designed to be used only with compressed air. To use fluids instead of compressed air, please contact SMC beforehand. 2.

Note 3) As the stroke increases, more sliding resistance may result due to the deflection of the piston rod and other factors. Take measures such as the installation of a Piston seal 1 pc. CG1Y32-PS Rod seal 1 pc. CG1Y40-PS CE2 Tube gasket 2 pcs. CG1Y50-PS Grease pack (10 g) 1 pc.

If it keeps on using, it may cause to break the equipment which is mounted by this product. 4. Inspect the cap for any cracks or wear. If the shock absorber comes with a cap, the cap could wear first. To prevent damage to the impact object, replace the cap often. 3.

This screw should not be removed, because dust may enter inside through the relieving port. Hexagon socket set screw is not prepared for clean room specifications, and use it as relieving port accordingly. CE1 CE2 ML2B Cycle Time Due to the nature of its construction, this cylinder starts and stops gradually.

(Assuming approximately 30% dispersion) There may be the case to change substantially depending on an ambient environment. 10-8-24

If the space is not sufficient, the magnets in adjacent cylinders may cause auto switches to malfunction. 2. In the case of bore size 6 cylinders with auto switches, keep the switch groove side surface at least 2.5 mm away from a magnetic substance. If a magnetic substance is getting closer within 2.5 mm, auto switches may malfunction due to a drop in magnetic force.

Data may be erased. 8. When mounting an air slide table, use appropriate length of screws and do no exceed the maximum tightening torque. Tightening with a torque above the limit could malfunction. Whereas tightening insufficiently could result in misalignment or come to a drop. 1. Do not scratch and dent the mounting side of the body and the table (guide block).


The ground terminal is used to obtain the reference potential for neutralization, so if it is not grounded, the discharge amount of the emitter may become unstable and the number of ions generated may decrease. In addition, even when the main unit power is ON without air purge, the discharge of the electrode needle may become unstable and the NDL LED may light up.


For example, for analog output 1 to 5 VDC types, the flow rate at 1 V may be 0 or it may be the min. rated flow rate.
In addition, for some models, the flow rate at 5 V may be the max. rated flow rate or it may be possible to change the flow rate.
Note) For PF2A series flow switches, the flow rate at 1 V/4 mA is the min. rated flow rate.

If the SI unit is not assembled properly, inside PCBs may be damaged or liquid and/or dust may enter into the unit. Technical documentation giving detailed diagnostics information can be found on the SMC website (URL http://www.smcworld.com).

If the SI unit is not assembled properly, inside PCBs may be damaged or liquid and/or dust may enter into the unit. Technical documentation giving detailed configuration information and the XDD file can be found on the SMC website (URL http://www.smcworld.com).

This connector may only be operated when under no load. Working with wet hands causes electric shock. Please never perform a repair.

Otherwise, malfunction may result due to noise. Ensure that the FG terminal is connected to ground when using a commercially available switch-mode power supply. When a switch-mode power supply is connected to the product, switching noise will be superimposed and the product specification can no longer be met.

If wires and cables are routed together with power or high voltage cables, malfunction may result due to noise. If a commercially available switching power supply is used, be sure to ground the frame ground (FG) terminal.

If wires and cables are routed together with power or high voltage cables, malfunction may result due to noise. If a commercially available switching power supply is used, be sure to ground the frame ground (FG) terminal.

A void stopping the pump for long hours., as this may prevent restart of the pump. C losing valve abruptly can generates surge, that considerably shortens the life of the pump. Discharge F low A djustment S ee C ircuit E xample 2 T o adjust flow from the discharge port, use ball valve on the discharge side.

When the pump is operated w ith discharge below the specification range, use bypass circuit from the discharge side to suction side for keeping the minimum flow inside the process pump. the pump may stop due to unstable operation w ith discharge flow less than minimum discharge flow .