SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q22-16-D-00N"

Magnet: D (Built-in Magnet), Mounting: A (Both Ends Tapped), Bore Size: 40mm, Port Thread: Bore 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: D (Double Acting), Rod End: Round Bar, Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: None, Auto Switch: M9N--Solid State, Gen.

Magnet: D (Built-in Magnet), Mounting: A (Both Ends Tapped), Bore Size: 20mm, Port Thread: Bore 16: M Thread; Bore 20 to 50: Rc, Stroke: 10mm, Action: D (Double Acting), Rod End: K (Chamfered), Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: None, Auto Switch: M9PA--Solid State, Water Resist., 3 Wire PNP, Horizontal

Magnet: D (Built-in Magnet), Mounting: A (Both Ends Tapped), Bore Size: 20mm, Port Thread: Bore 16: M Thread; Bore 20 to 50: Rc, Stroke: 10mm, Action: D (Double Acting), Rod End: K (Chamfered), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)

Magnet: D (Built-in Magnet), Mounting: A (Both Ends Tapped), Bore Size: 20mm, Port Thread: Bore 16: M Thread; Bore 20 to 50: Rc, Stroke: 15mm, Action: D (Double Acting), Rod End: Round Bar, Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: None, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)

Enclosure: W (IP67), SI Unit: EB (EtherNet/IPâ„¢ - 16 Outputs - Connector M12), SI Unit Output Polarity: N (-COM), Stations: 2 Stations, P, E Port Entry: D (D Side 2~10 Stations), SUP/EXH Block Assembly: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting: D0 (DIN Rail Mount w/o DIN Rail)

The use of 34 pin connectors allows up to 16 stations with double solenoids.Cassette base manifold for SV1000 valve, D-sub connector or flat ribbon cable, Number of connectors (D-sub): 25 pins, Number of connectors (flat ribbon): 26, 20, 10 pins, Maximum 18 stations available as standard, DIN rail mount 4/5 PORT SOLENOID VALVE. 5 Port Solenoid Valve Manifold. 681.9 lb. VVD.

The use of 34 pin connectors allows up to 16 stations with double solenoids.Cassette base manifold for SV1000 valve, D-sub connector or flat ribbon cable, Number of connectors (D-sub): 25 pins, Number of connectors (flat ribbon): 26, 20, 10 pins, Maximum 18 stations available as standard, DIN rail mount SS5V1 MANIFOLD SV1000. MFLD ASSY. VALVE. SS5V1 BUILT IN FITTING 1/4). 1.65346 lb.

The use of 34 pin connectors allows up to 16 stations with double solenoids.Cassette base manifold for SV2000 valve, D-sub connector or flat ribbon cable, Number of connectors (D-sub): 25 pins, Number of connectors (flat ribbon): 26, 20, 10 pins, Maximum 20 stations available as standard, DIN rail mount, 6 port sizes available 4/5 PORT SOLENOID VALVE.

The use of 34 pin connectors allows up to 16 stations with double solenoids.Cassette base manifold for SV2000 valve, D-sub connector or flat ribbon cable, Number of connectors (D-sub): 25 pins, Number of connectors (flat ribbon): 26, 20, 10 pins, Maximum 20 stations available as standard, DIN rail mount, 6 port sizes available 4/5 PORT SOLENOID VALVE.

Enclosure: W (IP67), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (-COM), Stations: 10 Stations, P, E Port Entry: D (D Side 2~10 Stations), SUP/EXH Block Assembly: Internal Pilot, A, B Port: N9 (5/16" One-touch Fitting)

Enclosure: W (IP67), SI Unit: FB (PROFINET - 16 Outputs - Connector M12), SI Unit Output Polarity: N (-COM), Stations: 5 Stations, P, E Port Entry: D (D Side 2~10 Stations), SUP/EXH Block Assembly: Internal Pilot, A, B Port: N3 (5/32" One-touch Fitting)

The use of 34 pin connectors allows up to 16 stations with double solenoids.Cassette base manifold for SV1000 valve, D-sub connector or flat ribbon cable, Number of connectors (D-sub): 25 pins, Number of connectors (flat ribbon): 26, 20, 10 pins, Maximum 18 stations available as standard, DIN rail mount 4/5 PORT SOLENOID VALVE. SS5V 05 Station Manifold, Cassette Base.

The use of 34 pin connectors allows up to 16 stations with double solenoids.Cassette base manifold for SV1000 valve, D-sub connector or flat ribbon cable, Number of connectors (D-sub): 25 pins, Number of connectors (flat ribbon): 26, 20, 10 pins, Maximum 18 stations available as standard, DIN rail mount 4/5 PORT SOLENOID VALVE. 5 Port Solenoid Valve Manifold. 446.6 lb. VVD.

The use of 34 pin connectors allows up to 16 stations with double solenoids.Cassette base manifold for SV2000 valve, D-sub connector or flat ribbon cable, Number of connectors (D-sub): 25 pins, Number of connectors (flat ribbon): 26, 20, 10 pins, Maximum 20 stations available as standard, DIN rail mount, 6 port sizes available 4/5 PORT SOLENOID VALVE.

The use of 34 pin connectors allows up to 16 stations with double solenoids.Cassette base manifold for SV2000 valve, D-sub connector or flat ribbon cable, Number of connectors (D-sub): 25 pins, Number of connectors (flat ribbon): 26, 20, 10 pins, Maximum 20 stations available as standard, DIN rail mount, 6 port sizes available 4/5 PORT SOLENOID VALVE.

The use of 34 pin connectors allows up to 16 stations with double solenoids.Cassette base manifold for SV2000 valve, D-sub connector or flat ribbon cable, Number of connectors (D-sub): 25 pins, Number of connectors (flat ribbon): 26, 20, 10 pins, Maximum 20 stations available as standard, DIN rail mount, 6 port sizes available 4/5 PORT SOLENOID VALVE.

The use of 34 pin connectors allows up to 16 stations with double solenoids.Cassette base manifold for SV2000 valve, D-sub connector or flat ribbon cable, Number of connectors (D-sub): 25 pins, Number of connectors (flat ribbon): 26, 20, 10 pins, Maximum 20 stations available as standard, DIN rail mount, 6 port sizes available SS5V2 MANIFOLD SV2000.

The use of 34 pin connectors allows up to 16 stations with double solenoids.Cassette base manifold for SV1000 valve, D-sub connector or flat ribbon cable, Number of connectors (D-sub): 25 pins, Number of connectors (flat ribbon): 26, 20, 10 pins, Maximum 18 stations available as standard, DIN rail mount SS5V1 MANIFOLD SV1000. MFLD, PLUG-IN, FLAT CABLE CONN. VALVE.

Enclosure: W (IP67), SI Unit: EB (EtherNet/IPâ„¢ - 16 Outputs - Connector M12), SI Unit Output Polarity: +COM, Stations: 5 Stations, P, E Port Entry: D (D Side 2~10 Stations), SUP/EXH Block Assembly: Internal Pilot, A, B Port: C6 (ø6 One-touch Fitting)

Enclosure: W (IP67), SI Unit: EB (EtherNet/IPâ„¢ - 16 Outputs - Connector M12), SI Unit Output Polarity: N (-COM), Stations: 4 Stations, P, E Port Entry: D (D Side 2~10 Stations), SUP/EXH Block Assembly: Internal Pilot, A, B Port: C6 (ø6 One-touch Fitting)