SMC Corporation of America
Elite Part Number Search
Search Results "ISE70-N02-AB-MAY"

MHC MHT Note) Sometimes the workpiece may not be gripped precisely because of excessive speed in finger opening and closing. Therefore, use a meter-in type speed controller to adjust the finger opening and closing speed. MHY MHW -X MRHQ MA D621 Angular Style Air Gripper Series MHC2-6/MHCA2-6 How to Order Number of auto switches Auto switch Nil S 2 pcs. 1 pc.

Since the sensor for stroke reading cylinder adopts the magnetic method, it may result in malfunction if there is a strong magnetic field around the sensor. Use it under the external magnetic field with 14.5 mT or less.

Otherwise, the clip may be deformed. If the clip is deformed by mistake, replace it with a new one. Collar Name plate Name plate The removal of the E stop ring will make it possible to remove the coil in direction w.

Auto switches may malfunction if a shielding plate is not used. Watchmaker's screwdriver Set screw Bore size (mm) Mounting pitch l (mm) 10 16 20 25 32 20 33 40 46 56 To tighten the auto switch mounting screws, use a watchmakers screwdriver with a grip diameter of 5 to 6 mm.

The flatness of the mounting surface may not be maintained, which would cause the sliding resistance to increase. 3. Make sure that the cylinder mounting surface has a flatness of 0.05 mm or less. If the flatness of the workpieces and brackets mounted on the plate is not appropriate, sliding resistance may increase. 4.

The keys may be used as program inputs in addition to their functions listed below. Table 3.1: Key Number and Basic Operation Key Name Key number Key Function OK K01 Used to enter menu options, conrm data entry, and manually force inputs in the monitor function.

Pressure Momentary change P1 P2 Set value Anti-chattering function Devices such as large bore cylinders and high-flow vacuum ejectors consume a large volume of air when they operate, and this may cause a momentary drop in the primary pressure.

Unintended operation may result. 2. Do not apply strong shocks (over 300 m/s2) to the pressure switch to prevent the switch from damage. AV AU AF Caution Flow rate (/min (ANR)) Inlet pressure (MPa) 1. Release the lock to adjust the pressure. After the adjustment, engage the lock.

Excessive impact may damage the switch inside. 4. During installation or removal of the sensor, use a wrench on the Hex.width across flats for PT threads. For M5 thread, use it on the rectangular parts beneath the body. If force is applied to the top of the body or resin case, damage may be caused to internal parts of the switch. 5.

Excessive torque or holding it at an area other than the specified portion may result in a malfunction. 2. While piping to products or operating the handle, ensure that an excess bending moment should not be applied to a product, because it may result in damage.

When installing a paddle on IF3O type, piping may be interfered with by the tip of a paddle. Because this is used to detect a small flow rate, and to narrow the distance between a paddle and piping, additional machining of the paddle tip may be necessary to eliminate interference between the two. 6. Use pipe fittings that comply with JIS specifications.

It may malfunction. Component Parts Caution No. q w e r t y u i Description Setting pressure adjusting bolt Scale plate Pointer Setting pressure adjusting spring Main lever Bellows assembly Adjusting bolt Snap switch (1a + 1b type) No. o !0 !1 !2 !3 !4 !

In locations where the switch is exposed to water and dust, etc., these may enter the switch from the atmospheric release port. Insert 4 tubing (inside diameter 2.5) into the atmospheric release port, and extend the other end to a safe area where water, etc., is not splashed or sprayed.

If the pressure differential at each port exceeds the values in the table below, valve leakage may occur. VDW 2 0 1 C1 1 VC OUT (2) VDW Series Lead wire length 1 2 3 10 20, 200 30, 300 300 mm 600 mm Nil L1 (1) IN 2 Port Valve VQ Note) Note) Type L1 is optional.

Sometimes when the bowl is removed for a purpose other than replacing the element, the spacer may stick to the bowl and come off. In this case however, it may be returned to its installed position and used again. 2. Drainage should be discharged by the time it reaches the upper limit.

The valve can malfunction due to air leakage. q Ensure connection so that air is supplied to the port "1(P)" Valve may have air leakage when air pressure is supplied from other ports.

(Hum sound may generate because of no shading coil for DC.) OReturn voltage is 20% or more of the rated value at AC power and 2% or more at the DC power. OAllowable voltage fluctuation is 10% of the rated voltage.

If cutting is done with tools other than tube cutters, the tubing may be cut diagonally or become flattened, etc. This can make a secure installation impossible, and cause problems such as the tubing pulling out after installation or air leakage.

If the product is used with the piping port released to atmosphere, accuracy may vary.

Note) If using the previous TS/TISA series with water, the tube may shrink and cause air leakage or the tube may fall out. 2. The products which changed the material are applicable for general industrial water. Please contact SMC if using other kinds of fluid. Surge pressure must be under the max. operating pressure.