Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE
Nozzle Diameter: 18 (ø1.8mm), Vacuum Pressure: S (-89 kPa), SUP: 03 (Screw-in Rc 3/8), VAC: 03 (Screw-in Rc 3/8)
Body Size/Type: 32 (Elbow Size 03 Standard), Control Type: 0 (Meter-out), 1: 1, Thread Type: G (G), Port Size: 03 (3/8), Applicable Tubing O.D: 10 (ø10)
Stations: 03 (3 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: Rc, Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj.
MANIFOLD, 4 STA, AIR OPERATED VALVE, 468 lb
10)W = 51n + 81, .41446 lb, ModelApplicable valveManifold typeP (SUP)/R (EXH)Valve stations Note)A, B port locationPort sizeManifold base weight W (g) n: StationsP, EA, EB portA, B portSS5X7-20SX7 20Single base/B mountCommon SUP/Common EXH2 to 20 stationsValveRc 1 4Rc 1 4C8 (One-touch fitting for ?8)C10 (One-touch fitting for ?10)W = 51n + 81
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Series VF, a five port pilot solenoid valve, offers large flow capacity in a compact size. The VF is available in many variations including three types of manual override and four types of electrical entry. Common exhaust for main valve and pilot valve is also available.VF5000 series manifold, Metric threads (Rc(PT)), Manifold type: B mount (single base), Maximum stations: 15, Port sizes
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, VV*F* MANIFOLD VF SERIES, 2J, VV*F* NO SIZE RATING, 1.83212 lb
"MFLD ASSY, VALVE, SS5Y7 MANIFOLD SY7000, 2J, SS5Y7 NO SIZE RATING, N lb
FKM (Fluoro rubber) is used for the fluid-contact rubber materials, allowing use even in ozone environments.Manifolds for VKF300 body ported valves , Stations: 1 to 20, Common SUP/Common EXH, Common SUP/Individual EXH, Optional bracket on Common EXH type, "MANIFOLD, 3 PORT SOLENOID VALVE
Series VF, a five port pilot solenoid valve, offers large flow capacity in a compact size. The VF is available in many variations including three types of manual override and four types of electrical entry. Common exhaust for main valve and pilot valve is also available.VF5000 series manifold, Metric threads (Rc(PT)), Manifold type: B mount (single base), Maximum stations: 15, Port sizes
Series VF, a five port pilot solenoid valve, offers large flow capacity in a compact size. The VF is available in many variations including three types of manual override and four types of electrical entry. Common exhaust for main valve and pilot valve is also available.VF5000 series manifold, Metric threads (Rc(PT)), Manifold type: B mount (single base), Maximum stations: 15, Port sizes
Series VF, a five port pilot solenoid valve, offers large flow capacity in a compact size. The VF is available in many variations including three types of manual override and four types of electrical entry. Common exhaust for main valve and pilot valve is also available.VF5000 series manifold, Metric threads (Rc(PT)), Manifold type: B mount (single base), Maximum stations: 15, Port sizes
Series VF, a five port pilot solenoid valve, offers large flow capacity in a compact size. The VF is available in many variations including three types of manual override and four types of electrical entry. Common exhaust for main valve and pilot valve is also available.VF5000 series manifold, Metric threads (Rc(PT)), Manifold type: B mount (single base), Maximum stations: 15, Port sizes
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, VV2Q* MANIFOLD VQ 2-PORT, 2J, VV2Q* NO SIZE RATING, 4.18878 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, VV2Q* MANIFOLD VQ 2-PORT, 2J, VV2Q* NO SIZE RATING, 4.18878 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, VV2Q* MANIFOLD VQ 2-PORT, 2J, VV2Q* NO SIZE RATING, .00000 lb
Membrane air dryer series, Single unit style, 10 sizes available, Port sizes: 1/8" to 1/2", AIR DRYER, MBRANE(600/125)-20, OTHERS, IDG 3/8 MEMBRANE AIR DRYER, 3.93441 lb, ModelRange of operating conditionsStandard perfor- manceStandard performance conditionsDew point indicator purge air flow ratePort size (Nominal size B)Weight (kg) (With bracket)FluidInlet air pressure (MPa)Inlet air
Membrane air dryer series, Single unit style, 10 sizes available, Port sizes: 1/8" to 1/2", AIR DRYER, MBRANE(500/125)-20, OTHERS, IDG 3/8 MEMBRANE AIR DRYER, 1.78574 lb, ModelRange of operating conditionsStandard perfor- manceStandard performance conditionsDew point indicator purge air flow ratePort size (Nominal size B)Weight (kg) (With bracket)FluidInlet air pressure (MPa)Inlet air