Selection conditions Mounting: Horizontal Maximum speed: 500 mm/s Load eccentricity L1: 50 mm Overhang L: 30 mm Load mass m: 0.1 kg Refer to Graph 0 based on horizontal mounting, a speed of 500 mm/s and load eccentricity L1 of 50 mm.

only) Nil N Metric sizes Inch sizes Nil S Resin Stainless L LQ-GP 2 J 07 Tubing size symbol (refer to Table 1) Body class (refer to Table 1) Insert pin (single) Insert pin material (J/K type only) Type Nil S Resin Stainless LQ-GH J 07 Holder (single) Tubing size symbol (refer to Table 1) Type Note1) Replacement part type J shows the parts for LQ-GJ and LQ-GK.

VVZ400-32A-11 pc. (Blanking plate) VV3Z4-50-061-01 (6 stations) VZ415-1G3 pcs. VZ425-1G2 pcs. VVZ400-32A-21 pc.

Sensitivity 0.5% F.S. 1% F .S. 1.5% F .S. 2% F .S. Repeatability 0.5% F.S. 1% F.S. 1% F.S. 2% F.S.

Reed switch Auto switch A90 Solid state M9B, M9N, F8B, F8N Size: 10, 20, 30, 50 11 Vacuum suction type Clean series 10 Size 20 30 50 11 MSQ B 10 A M9B 22 MSQ B 10 A M9B Number of auto switches A High precision type B Basic type Nil S n 2 pcs. 1 pc. n pcs.

Location where vacuum pressure is measured Piping length (m) Vacuum source Adjust the measured vacuum pressure using a regulator to be the value in the graphs below. 0 -0.001 -0.002 -0.003 -0.004 -0.005 -0.006 -0.007 -0.008 -0.009 -0.010 -0.011 -0.012 11-CJ2 11-CM2 11-CQ -0.027 13-MXS16 Vacuum pressure (MPa) Vacuum pressure (MPa) -0.028 13-MJP 13-MXS20 -0.029 11-CU -0.030 13-MXS25 -0.031

Fittings & Tubing Air Cylinders Rotary Actuators 2 x P (Rc, NPT, G) H2 Width across flats B2 2 x NN G Relief port M5 x 0.8 G H1 Width across flats B1 Standard port I Relief port 2 x Eh8 D MM AL A F K NA N N H S + Stroke F ZZ + Stroke (mm) ZZ S P N I E D A 12.5 11 10 10 13 F Bore size Stroke range AL K MM NA NN G H2 41 32 32 26 B2 H H1 22 17 17 13 B1 0 6 6 5 8 8 8 50 45 45 41 200 to 1000 150

The value of the effective area S, like that of sonic conductance C, expresses the ease of flow. (3) Formula for flow rate When P2 + 0.1 0.5, choked flow P1 + 0.1 293 Q = 120 x S (P1 + 0.1) (3) 273 + t When P2 + 0.1 > 0.5, subsonic flow P1 + 0.1 293 Q = 240 x S (P2 + 0.1) (P1 P2) (4) 273 + t Conversion with sonic conductance C: S = 5.0 x C(5) Q : Air flow rate [dm3/min (ANR)], dm3

Window of I/O Configurator (NFC version) 11 3.1. Basic characteristics 11 3.1.1. Login to administrator mode 13 3.2. Display for Wireless Base 14 3.2.1. Information tab 14 3.2.2. Input/Output monitor tab 16 3.2.3. Setting tab 20 3.3. Display for Wireless Remote 30 3.3.1. Information tab 30 3.3.2. Input/Output monitor tab 32 3.3.3. Setting tab 36 3.4.

Window of I/O Configurator (NFC version) 11 3.1. Basic characteristics 11 3.1.1. Login to administrator mode 13 3.2. Display for wireless master 14 3.2.1. Information tab 14 3.2.2. Input/Output monitor tab 16 3.2.3. Setting tab 20 3.3. Display for wireless slave 30 3.3.1. Information tab 30 3.3.2. Input/Output monitor tab 32 3.3.3. Setting tab 36 3.4.

Window of I/O Configurator (NFC version) 11 3.1. Basic characteristics 11 3.1.1. Login to administrator mode 13 3.2. Display for wireless master 14 3.2.1. Information tab 14 3.2.2. Input/Output monitor tab 16 3.2.3. Setting tab 20 3.3. Display for wireless slave 30 3.3.1. Information tab 30 3.3.2. Input/Output monitor tab 32 3.3.3. Setting tab 36 3.4.

TL TG effective depth TL TD TB TC D (g6) DD (h9) A AU B BA BB BE J JA JB BC BD BU CA CB F H Size Rotation 20 30 90, 180 90, 180 40 90, 180 16 16 5.2 10 12 15 8.3 32 30 32 36 6.5 8.5 8.6 2.5 3 3 63 (11) 50 14 34 69 (11) 68 14 39 14.5 16.5 49 30.4 34.7 4.7 4.9 7 8.1 25 30 11 14 14 M8 x 1.25 M10 x 1.5 M10 x 1.5 78 (13) 76 16 47 18.5 55 40.4 Size Rotation K Q S W Key dimensions TF (H9) TG (

Load weight kg Load weight kg m s m s Type of impact s m 1 2 m2 Kinetic energy E1 Thrust energy E2 Fs Fs + mgs Fs mgs Absorbed energy E E1 + E2 Symbols : Speed of impacting object (m/s) m: Mass of impacting object (kg) F: Cylinder thrust (N) g: Gravitational acceleration (9.8 m/s2) s: Shock absorber stroke (m) Note) The speed of the impacting object is measured at the time of impact

Gap too small Green 2 a Place the gap gauge on the detection nozzle for precise adjustment. s Confirm applied air pressure.

Material Code Body Poppet 316L SS Diaphragm 316L SS Nozzle Seat material S Material PCTFE (Standard) PTFE 3) Code 316L SS 316L SS Hastelloy C-22 Hastelloy C-22 No code TF SHP 3) PTFE recommended for applications such as within a process tool.

(mm) H I J K L C D E F U A B Z M N O P S Bore size (mm) 32 M10 x 1.5 60 4.5 14 8.5 82 12 16 45 20 31.5 65 14 34 5.5 9 depth 7 Rc1/8 58.5 40 M10 x 1.5 69 5 14 8.5 84 12 16 52 22 35 67 14 40 5.5 9 depth 7 Rc1/8 66 50 M12 x 1.75 86 7 18 11 98 15 20 64 25 41 76 19 50 6.6 11 depth 8 Rc1/4 80 63 M12 x 1.75 103 7 18 11 102 15 20 77 27 47.5 80 19 60 9 14 depth 10.5 Rc1/4 93 80 M16 x 2 132 6 22 11

Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Buffer mounting (Male thread) Buffer mounting (Male thread) Mounting Male thread Female thread Female thread Vacuum entry port Female thread Common Female thread Female thread Female thread P. 13-11-91 to 92 P. 13-11-86 to 88 P. 13-11-86 to 88 P. 13-11-89 to

MGPS50 50 11 12 A 13 B 14 1 2 3 4 5 50 80 7 8 9 A 10 B 15 16 6 17 NBR 18 NBR 19 A NBR 20 B NBR / (mm) 50 MGP50-PS 19 18 17 80 MG80-PS 20 17 20 GR-S-010(10g 18 18. 18-1.

(Initial value) Note 3) Value for high pressure type (1.5W) specification Note 4) Value for the low power consumption (0.5W) specification 56 Series VQ1000 VQ1000/Flat Cable Kit Stations VV5Q13J 0(D) U S Applicable connector: Flat cable connector (20P) (conforms to MIL-C-83503) L2 23.5 P = 11 13.2 L1 6.2 41 35 Indicator light 1.5 1.5 (11) 19.5 (Mounting hole dimension) Manual override 2-