PF2A5--2 (With voltage output type) PF2A511, 521, 551 B Wiring 116 23 1.6 76.2 Brown (1) DC(+) Main circuit Black (4) OUT (Output for display unit) White (2) NC/Analog output 54 44 34 Blue (3) DC() Use this sensor by connecting it to a P/A remote type display unit Series PF2A2/3. 4-4.5 2-Port size 30 40 50 Connector pin numbers 2 1 (44.2) A 4 3 (mm) A B Output specification Pin no.
CHKDB Bore size Rod end thread type Auto switch Quantity XC64 Stroke With air release valve Dimensions CHKDB--XC64 A C C B A B C Bore size (mm) 20 16.5 14.5 7 25 17 15 8 32 19.5 17 10 40 20.5 17.5 10 50 22 19.5 10 63 25.5 22 10 80 30 26.5 15 100 36 33 15 Note) Dimensions other than those highlighted above are standard. 12
Supply port 2-M5 x 0.8 FC FA FE FH GD GC GB FG FF EB EA D FB B MIS12-10 A C FD GA Model 72 92 112 86.5 106.5 126.5 33 43 53 38.5 48.5 58.5 48 38 28 165 135 105 185 155 125 MIS12-30 MIS12-20 18 19 9.5 6 (Effective depth 3) 4.5 8 -0.1 0 8 -0.1 0 10 M3 x 0.5 5 3.3 23 26 21 MIS20-30 MIS20-20 MIS20-10 52 42 32 11-0.1 0 11-0.1 0 29.5 35 25.5 13 12.5 10 (Effective depth 4) M5 x 0.8 6.5 28.5 7 5.1
3-R1.5 2-4.5 through ( A , B , C ) 15.5 45 9 2 36 3 42h9 0 0.062 8 11 8 1.5 5 5 18.3 29 11 Angle adjustment bolt 2-4.5 through 3-R1.5 6 2-M5 x 0.8 Adjustment: Max. 8.2 6 B port A port 0.5 +0.025 0 3-3H9 long groove depth 2.5 ( A , B , C ) 5g6 0.004 0.012 12h9 0 0.043 4-M4 x 0.7 depth 8 34 0 0.062 42h9 Top ported: MSUA3-SE 36 10 A port B port 2-M3 x 0.5 11 11-5-10 10 Series MSUA Rotary Table
Note 3) The value at a temperature of 20C, with a 10% or less O.D. variable rate.
Select a robotic cable (flexible cable) when repeated bending of the actuator cable is required. Also, do not put cables into a flexible moving tube with a radius smaller than the specified value (50 mm or longer). Electric shock, wire breakage, contact failure, or a loss of product control may occur if standard cables are used for repeated bending. 10.
Reed switch Auto switch A90 Solid state M9B, M9N, F8B, F8N Size: 10, 20, 30, 50 11 Vacuum suction type Clean series 10 Size 20 30 50 11 MSQ B 10 A M9B 22 MSQ B 10 A M9B Number of auto switches A High precision type B Basic type Nil S n 2 pcs. 1 pc. n pcs.
Data The stop and skip valves must be normally closed. 10-17-5 6 Air-hydro Unit Series CC How to Order The air-hydro unit consists of a converter and a valve unit that are compactly integrated.
Flow rate Ql /min VDW 1.6 CV = 0.07 10 20 VDW VDW 1.6 CV = 0.07 10 20 5.0 VDW10 VDW10 1 CV = 0.03 VDW10 1 CV = 0.03 1.0 0.1 0.001 0.01 0.1 1 10 Pressure differential P = (P P) MPa Viewing the graph To generate a water flow of 4l/min at a differential pressure of 0.1MPa, an effective area with Cv factor 0.28 (VDW303) or more is required.
5 +10 7 5 < Cp 10 Cw 0.5 8 0.5 < Cw 5 9 5 < Cw 10 x Cp > 10 Cw > 10 > 5 [How to Perform a Test to Check the Performance] ISO 12500, which sets out the test method to be used in order to check the filter performance for each of the three kinds of contaminants, is indicated below.
from Top of Auto Switch CLKG CKQ CLKQ 50 Safety distance L1 (mm) CK CLK 40 Operational range 30 CKQ L1 20 L1 Dangerous range 10 0 5000 10 15000 20 Welding current (A) 50 Safety distance L2 (mm) 40 30 L2 L2 Operational range 20 10 0 5000 10 15000 20 Welding current (A) D-X 439 CK1 Series Related Products Please contact SMC for detailed dimensions, specifications and lead times.
LED PLC ON/OFF 8 ST(M) () ST(M) SI 9 ST(M) PWR () DC24 V10 10 PWR(V) () DC24 V+10/-5 :(66 ) -31No.EX-OMQ0015CN No. 1 PROFINET L/A IN L/A INL/A OUT LINK L/A INL/A OUT OUT L/A OUT 11 PLC PLC RUN L/A INL/A OUT LINK SF BF () LEDNo.27 SF BF PLC 12 PLC OFF PLC SI PLC SI Device Name SF BF PLC SI PWR(V)LED DC24 V+10/-5% SI SI 13 SI EX600-SPN1(PNP) EX600-SPN2
Suitable for slow operation of a rotary actuator. CC CC Integrate a converter and a valve unit in a compact configuration. Possible to select 4 types of valve units for applications. Possible to connect a converter and a valve unit independently. Wide range of series in terms of converter capacity and valve unit flow rate control capability.
Only reading is available Reading and writing are available 5.3 Setting and checking HRS090 Series 5-10 HRX-OM-T004 Chapter 5 Simple communication protocol function 5.4 Communication sequence Starts with a request message from the customers system (host), and finishes with a response message from the product (slave). This product operates as a slave. It does not send any requests.
18.7 10 24 Rc1/4 NPT1/4 G1/4 40 10 54 31 3 6.7 19 109 49 6 20.6 12.5 23 Rc1/4 NPT1/4 G1/4 Note 1) Dimensions when equipped with auto switch are the same as drawing above.
Note 2) Refer to page 10 for lead wire length. Caution Operation instructions Consult P/A when using solvents other than water.
Applicable rotary actuator Applicable air gripper Size Page Size 30 50-100 10/15 20-100 10/15 20-40 32/40 1/3 7/20 10-200 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB CDRQ MRQ MDSUB MSQ MHZ2 MHZJ2 MHL2 MDHR MHS 12-25 MHK MHS MHC2 MHT2 MHW2 10-25 10/16 MHY MRHQ 2.11-8 D-A72/A73/A80 Grommet D-A72H/A73H D-A76H/A80H 2.11-9 Rail Connector 2.11-10 D-A73C/A80C D-A53/A54/A56
Only reading is available Reading and writing are available 5.3 Setting and checking HRSH Series 5-10 HRX-OM-R028 Chapter 5 Simple communication protocol function 5.4 Communication sequence Starts with a request message from the customers system (host), and finishes with a response message from the product (slave). This product operates as a slave. It does not send any requests.
O-ring Port plug Body Ported Base Mounted Blanking plug (For One-touch fittings) KJP-02 A L Dimensions [mm] Applicable fitting size d Model A L D Weight [g] 2 KJP-02 8.2 17 3 0.1 3.2 KQ2P-23 16 31.5 5 1 4 KQ2P-04 16 32 6 1 23 KQ2P-04 D Silencer (For manifold EXH port) Body Ported Base Mounted Silencer is installed in the EXH port.