SMC Corporation of America
Elite Part Number Search
Search Results "CDLA2C100-800-E"

Please contact us for the latest version.sales@ocaire.com, ITV CONTROLLER, 4-CHANNEL, INSTRUMENTATION, IT/ITV0000/1000 E/P REGULATOR, 2X, IT1000 NO SIZE(MISC.

ITV CONTROLLER, 4-CHANNEL, INSTRUMENTATION, IT/ITV0000/1000 E/P REGULATOR, 2X, IT1000 NO SIZE(MISC.

Please contact us for the latest version.sales@ocaire.com, ITV CONTROLLER, 4-CHANNEL, INSTRUMENTATION, IT/ITV0000/1000 E/P REGULATOR, 2X, IT1000 NO SIZE(MISC.

Please contact us for the latest version.sales@ocaire.com, ITV CONTROLLER, 4-CHANNEL, INSTRUMENTATION, IT/ITV0000/1000 E/P REGULATOR, 2X, IT1000 NO SIZE(MISC.

Series: LEKFS, Size: 25, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 800, Motor Option: B (with Lock), Seal Band Stopper: N [Roller Type Seal Band Stopper [Grease Free]], Actuator Cable Type, Length: R1 (1.5), Controller: C61 (JXC61, Parallel I/O), Controller Mounting: 8

Cooling Capacity: 008 (800 W), Power Supply: W5 (100 to 240 VAC), Pipe Thread: N (NPT), Feet: E (w/Feet and No Rack Mounting Brackets), Flow switch: None, Tank with Diagonal Fill Port: J (Diagonal Fill Port)

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 160, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Magnet: D (Built-in), Mounting: C (Single Clevis), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Magnet: D (Built-in), Mounting: C (Single Clevis), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Magnet: D (Built-in), Mounting: C (Single Clevis), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 350mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Magnet: D (Built-in), Mounting: C (Single Clevis), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Magnet: D (Built-in), Mounting: C (Single Clevis), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 75mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Magnet: D (Built-in), Mounting: C (Single Clevis), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 700mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)

Magnet: D (Built-in), Mounting: C (Single Clevis), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 100mm, Option: J [Nylon Tarpaulin, Cushion: Both Sides (Air-hydro has No Cushion)], Lock Operation: P (Air Pressure Lock-up)

Magnet: D (Built-in), Mounting: C (Single Clevis), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 700mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Magnet: D (Built-in), Mounting: C (Single Clevis), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 160, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Magnet: Built-in, Mounting: Single Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -

Magnet: Built-in, Mounting: Single Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -