The dryer comes already fitted with tubing in flexible plastics (6 mm in diameter and 1500 mm long) for the connection to the collection plant. The condensate drain occurs through a solenoid valve protected with a mechanical filter. In order to avoid clogging of the solenoid valve, the condensate coming from the cyclone separator is previously filtered, than discharged.
Specifications Body Size (in.) 1/4 3/8 1/2 3/4 1 1-1/4 1-1/2 2 Maximum Rated Pressure (PSI) 5000 5000 5000 5000 4000 4000 4000 3000 Except the following port options in the noted size 03 (Male JIC 37) 3000 2000 05 (Male SAE O-Ring Boss) 2500 06 (Female JIC 37) 90 Housing Port 4000 3000 3000 2500 2000 06 (Female JIC 37) In-Line Housing Port 3000 2000 07 (Female NPSM) 4600 3000 2600 2100 1650 1500
Rated voltage (with connector and 2 of sockets only) Lead wire length Nil 300 mm 6 600 mm Electrical entry 5 24 VDC 6 12 VDC 10 15 20 25 30 50 1000 mm G Grommet, 300 mm lead wire H Grommet, 600 mm lead wire 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm V 6 VDC S 5 VDC L With lead wire L plug connector R 3 VDC LN Without lead wire 50 60 1 100 VDC Hz LO Without connector With lead wire Without lead
With light/surge voltage suppressor (Non-polar type) : SY100-30-A U Without lead wire (with connector and 2 of sockets only) Lead wire length Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Rated voltage 5 6 V S R 1 2 Electrical entry 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] G H L LN LO M MN
S Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R Lead wire length U 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.
Model: 20 (1500 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 1 (Current Style 0~20mADC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: Rc(PT), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: None, Cable Connector: L (Right Angle Style 3m)
Model: 20 (1500 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 1 (Current Style 0~20mADC), Monitor Output: 1 (Analog Output 1~5VDC), Thread: Rc(PT), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: None, Cable Connector: N (w/oCable Connector)
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
Rotations per Second Distance of movement per second Distance of movement per rotation Rotation Speed (rpm) = Speed (mm/s) Lead (mm) }60 (S) = {500 (mm/s) 20 (mm) }60 (s) =1500 (rpm) -25- 5.3.3 Acceleration/deceleration time configuration < Acceleration/deceleration time Configuration> Acceleration/deceleration time (ms) configuration: The acceleration/deceleration time sets the amount
Rotations per Second Distance of movement per second Distance of movement per rotation Rotation Speed (rpm) = Speed (mm/s) Lead (mm) }60 (S) = {500 (mm/s) 20 (mm) }60 (s) =1500 (rpm) -36- 6.6.3 Acceleration/deceleration Time Configuration < Acceleration/deceleration Time Configuration> Acceleration/deceleration time (ms) configuration: The acceleration/deceleration time sets the amount
Rotations per Second Distance of movement per second Distance of movement per rotation Rotation Speed (rpm) = Speed (mm/s) Lead (mm) }60 (S) = {500 (mm/s) 20 (mm) }60 (s) =1500 (rpm) -38- 6.6.3 Acceleration/deceleration Time Configuration < Acceleration/deceleration Time Configuration> Acceleration/deceleration time (ms) configuration: The acceleration/deceleration time sets the amount
ZL3 ZL6 ZL6 14 1 7 15 PBT 2 POM 16 POM 2 3 PBT 17 PBT 4 POM 18 5 FKM 6 PBT 19 7 PBT 3 6 8 1 PBT 20 , 9 1 4 1 10 2 21 11 2 PBT 5 22 12 POM 8 13 3 O HNBR/NBR 16 No.ZL3-OM00801-A 7.2 1 (/) ZL3/ZL6 ZL3-JSY3140-5LZ -a 1 3) 2) DC24V 1) 300mm 300mm * *0.150.18Nm 2) D: E: 1 1 1 1 3) 1 1 2 X12 ZL3/ZL6 SY100-30-4A-6 1 2) / 1) 2) 300 4 DC24V 6 600 10 1000 15 1500
IDFA100F150F 5 1 5.1 IDX-OM-U022 5. ( ) ( ) 60cm 1 10% 3 ( ) 60cm 1 2 INOUT INOUT () IDFA100F150F 5 2 5.1 IDX-OM-U022 5. 5.2 1-3 5.1 3.7 OFF () ON OFF ON IDFA100F150F 5 3 5.2 IDX-OM-U022 5. 5.3 R () OFF OFF OFF ON ON IDFA100F150F 5 4 5.3 R IDX-OM-U022 6. ence 6.1 IDFA100F-38IDFA125F-38IDFA150F-38560 MPa 0.151.0 / K 0.151.6 () 245 (85%) (ANR) 1 ) 960 1210 1500
SI unit and input devices are connected ) Communication method Protocol: Dedicated for SMC Speed: 750kbps Number of branches for input/output 4 branches ( 16 points/branch ) for input 4 branches ( 16 points/branch ) for output Loop resistance 110 /km Capacity 30pF/m or less Impedance 135 165 Cable length [m] 1200 1000 400 200 100 Transmission rate [kbps] 9.6 19.2 45.45 93.75 187.5 500 1500
DC-DC Converter (Insulation) 19.2 kbps 45.45 kbps 93.75 kbps 187.5 kbps Communication speed Max. wiring length 9.6 kbps 1200 m 1000 m GND +24 V TD+ TD0 V Power supply for output INPUT OUTPUT 100 m Max. wiring length Communication speed 500 kbps 1500 kbps 3000 kbps 6000 kbps 12000 kbps 400 m 200 m +24 V 0 V COM D : Max. wiring length differs depending on the specification of a cable.
005 500 mm SSPS 010 1000 mm SAPA 020 2000 mm 030 3000 mm 050 5000 mm 100 10 mm (EX9-ACMJ-SSPS) (EX9-ACMJ-SAPA) CC-Link A code A code 54 7.7 mm 0.5 mm 2/AWG20 0.34 mm 2/AWG22 2.55 mm 77 mm -30No.EX-OMP0004CN-I (1) EX9-AC0 1 0-1 L 1 1000[mm] 3 3000[mm] 5 5000[mm] B code No. 6.6 mm 1 DC24 V() AWG22 2 0 V() 1.65 mm 3 DC24 V() 40 mm 4 0 V() 5 (2)(SPEEDCON ) PCA-140180 7 L 7 1500
PCT200 W/ SIEM S7-1500 PLC & FAULT INS, TRAINING EQUIPMENT, H25, 12.70000 lb
Auto switches are available on most models.Tie-rod type low pressure hydraulic cylinder, Bore sizes *: 40, 50, 63, 80, 100, 125, 160, Standard strokes *: 25 to 1500, 3.5MPa, 8 mounting styles, Aluminum tube type is auto switch capable, Hydraulic Cylinder, HYDRAULIC CYLINDER, CH, CC, HC, 345, 11.30000 lb