SMC Corporation of America
Elite Part Number Search
Search Results "CDNGBA32-250-D"

Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Fig. 3-13 Connection of RS-232C HRS Series 3.3 Installation 3-25 HRX-OM-W032 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly. Incorrect piping might cause leakage of supplied or drained fluid and wet surrounding area and facility.

Hold the end of the tubing and insert it all the way in. 840 Clean Exhaust Filter SFE Series Dimensions SFE11 Gasket M5 9 4 25 SFE42/52/53/73 Dimensions (mm) C A Model A B C D SFE42 10 62 16.5 R1/8 SFE52 10 71 20.5 R1/8 SFE53 17 75 20.5 R1/4 SFE73 17 84 24 R1/4 D B SFE3A 4 13.5 59 SFE4B/5C/7D AN A C Dimensions (mm) AMC Model A B C SFE4B 6 73 16.5 SFE5C 8 84 20.5 SFE7D 10 94 24 B AMV AMP SFE

Dimensions/20 to 40 Basic/CM2YB Width across flats B2 2-P (Port size) (Rc, NPT, G) 2-NN H1 H2 G G Width across flats B1 I 2-Eh8 D MM AL A F F NA 1.5 1.5 N N K H S + Stroke ZZ + Stroke Boss-cut ZZ + Stroke (mm) A AL B1 B2 D E F G H H1 H2 I K MM N NA NN P S ZZ Bore size (mm) 20 25 32 40 0 0.033 0 0.033 0 0.033 0 0.039 18 15.5 13 26 8 13 8 41 5 8 28 5 M8 x 1.25 15 24 M20 x 1.5 1/8 62 116 20

INSTALLATION B D Installation Transmission Din & Feed-back lever Fig. SINGLE-ACTING ACTUATOR SIGNAL PRE-Y%i-rpur SIGNAL RANGE INSTALLATION STYLE IREF. FIG. 1) OUT 1 OUT2 Direct ? OPEBATION ACTUATOR 315 DSi used pruggeo 1/2 Solit D c pruggeo used 1/2 Solit B 3-15 osi c USEO plugged '1l2 Solit B 3-15 nsi pruggeo used '112 Solit D Fig. Reverse = ) Y INSTALLATION STYLE (REF.

(M10) Unitinch [mm] A B C D E F G H J K L M N P Q R 31.5 34.2 IDFB55E 2 1.4 [800] [868] 18.5 33.7 5.0 17.9 4.3 9.8 2 0.5 19.70.1 3.0 27.60.04 20.7 20.40.2 [470] [855] [128] [455] [110] [250] [50] [13] [5002] [75] [7001] [526] [5195] [36] 35.4 38.1 IDFB75E 2 [900] [968] IDFB Series 6-3 6-2 IDX-OM-W035 6 6-4 IDFB22E-11 IDFB22E/37E-23 R GFCI GFCI R GFCI R GFCI L N PE R TB1 PE N L 1 2 TB1

E 2 IISA2 *1 16 1~6 C +2 *2 *A V 2 E2 (MPa) 0.2MPa 0.4MPa G2 (MPa) *P2 (MPapsi) SR *Z2 (psi) SL E4 (MPa) PR G4 (MPa) PL *P4 (MPapsi) * *Z4 (psi) * *1psi *21/8 B D DIN + 2 C 1 AC100V M 2 AC200V W 3 AC110V 4 AC220V 2 5 DC24V D DIN 6 DC12V DL DIN() 36 AC230V DO DIN() T TL () * -11No.PS-OMF0005CN-E G E 2 1 ISA2 G 0.25mm *L L H 0.5mm N P * Rc1/8 N NPT1/8 *F G1/8 1 NPN * 5

Output specifications Symbol OUT1 OUT2 A NPN NPN B PNP PNP C NPN Analog (1 to 5 V) D NPN Analog (4 to 20 mA) E Note 2) PNP Analog (1 to 5 V) F Note 2) PNP Analog (4 to 20 mA) G Note 2) NPN External input Note 3) Unit specifications Nil Unit selection function Note 5) M SI unit only Note 6) Note 5) Since the unit for Japan is fixed to SI due to new measurement law, this option is for overseas

conditions] HRS150-A-20 Circulating fluid temperature: 41 to 95F (5 to 35C) Fan 0 41 50 59 68 77 86 95 104 Circulating fluid temperature [F] Ambient temperature: 90F (32C) Air-cooled condenser fan Cooling valve Heating valve Power supply: 200 VAC/50 Hz Circulating fluid flow rate: Rated flow Existing model (Pump heat input only) Heating valve control Circulating fluid: Water 0 50 100 150 200 250

SUP. 3 1 2 3 1 2 3 1 2 E Padlock mounting position D C SUP J 2 2 x K A T IN OUT AA 3 L 2 x P1 (Port size) B V BB U Built-in silencer (Option) M (Width across flats) 3 N P2 (Port size) Q EXH Y Bracket (Option) R S X W Dimensions (mm) Standard specifications Model P1 P2 A B C D E F G H I J K L M 1/8, 1/4 1/4, 3/8 1/8 1/4 3/8 1/2 1/2 66.4 80.3 104.9 110.4 134.3 22.3 29.4 38.5 42 53 40 53 70

E EtherCAT 9 EtherNet/IP P PROFINET D DeviceNet L IO-Link Mounting 7 Screw mounting 8*1 DIN rail *1 The DIN rail is not included. It must be ordered separately. (Refer to page 7.) * Only the step motor type is applicable.

Fan Circulating fluid temperature [C] [Test conditions] Circulating fluid temperature: 5R35C Ambient temperature: 32C Power supply: 200 VAC/50 Hz Circulating fluid flow rate: Rated flow Circulating fluid: Water External piping: Bypass piping HRSE Air-cooled condenser fan HRZ Cooling valve Heating valve HRZD Heating valve control Current model (Pump heat input only) HRW 0 50 100 150 200 250

VCHR 12 2 1 2 1 2 1 1 ITV 2 1 2 1 2 1 2 1 2 1 L 2 2 1 L L L IC AFM AF ARP AFM AF ARP 10 ITVX c Control a clamping force by precise pressure control. d Release residual pressure with the backflow function. Residual pressure circuit Also exhausts residual pressure completely. Sensitivity within 0.2% F.S. allows more precise pressure adjustment. Repeatability within 1% F.S.

SRF 12 2 1 2 1 2 1 1 ITV 2 1 2 1 2 1 2 1 2 1 L 2 2 1 L L L IC AFM AF ARP AFM AF ARP 10 ITVH c Control a clamping force by precise pressure control. d Release residual pressure with the backflow function. Residual pressure circuit Also exhausts residual pressure completely. Sensitivity within 0.2% F.S. allows more precise pressure adjustment. Repeatability within 1% F.S.

NPN(1 )+ (15 V) PF2A7--29--X560 NPN(1 )+ (420 mA) 22 PF2A7--68--X560 PNP(1 )+ (15 V) PF2A7--69--X560 PNP(1 )+ (420 mA) / ZS-37-A () 3 m 100 g ZS-37-B (L ) 3 m 100 g ZS-29-T 4 (312 ) 40 g -11No.PF-OMO0007CN (IN ) 1 DC(+) 2 OUT2 3 DC(-) (OUT ) 4 OUT1 INOUT (UP) (SET) (DOWN) LED (OUT1) (OUT2) (OUT1) LED (OUT1) OUT1 ON (OUT2) OUT2 ON (UP) ON/OFF (SET) (DOWN) ON/OFF -12No.PF-OMO0007CN D

[F 2] OUT2 -37No.PF-OMN0011CN-C d. ([ tP]) 4. [F 2] OUT2 e. ([ tPL]) [ tPH] or [ tnH] ([ tPH]) 4.

e f g Nil Reed switch L R Solid state switch S h Nil L R S Operating direction Left Right a b h g d c f e Note) Lead wire length symbols 0.5m .

Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: TN (NPT), Stroke: 400mm, Option: N (w/o Cushion), Cylinder Switch Type: M9PV--Solid State , Gen.

Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: TN (NPT), Stroke: 400mm, Option: N (w/o Cushion), Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.

CM01-8DP4S DDK Ltd. 10 Series PF2A Dimensions PF2A703H, 706H, 712H D E Internal circuits and wiring examples to are terminal numbers.