SMC Corporation of America
Elite Part Number Search
Search Results "CDS2B140-125"

The CS1 air cylinder offers 3 bore sizes (125, 140 & 160mm), 7 mounting options, and is auto switch capable.  Other options include rod boots & cushions.   Double acting, single rod, low friction; Available with Rc, NPT or G port threads; Bore size (mm): 125, 140, 160; Auto switch capable; Variety of lead wires or prewired connectors

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Specification: Without built-in magnet, Support bracket: Through-hole

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Specification: Without built-in magnet, Support bracket: Through-hole

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Specification: Without built-in magnet, Support bracket: Through-hole

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Specification: Without built-in magnet, Support bracket: Through-hole

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches: Without auto

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch, Lead Wire Length

LXP ELECTRIC ACTUATOR WITH GUIDES Low Profile Electric Actuator With Guides; 2 Phase / 5 Phase Stepping Motor; Stroke Length Options: 50, 75, 100, 125, 150, 175, 200mm. LXS ELECTRIC SLIDE TABLE WITH HIGH RIGIDITY GUIDES Electric Slide Table with High Rigidity Guides; 2 Phase / 5 Phase Stepping Motor; Stroke Length Options: 50, 75, 100, 125, 150mm.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com IR Level gauge VEX Model Metal bowl Metal bowl with level gauge Model Port size AMR B C E D A B B 275 280 307 312 AL800 AL900 AL800 AL900 125 125 1 ,1 2 1 4 1 2 100 100 283 288 59 63 ITV IC Option Specifications/1000 cm3 Tank VBA VE VY1 Port size G PPA

Lube Unit Mounting thread M12 Float switch mounting position J (Bracket mounting dimensions) Panel (Option) Bracket (Option) A B C D E F G H J K L M N P Q R S Model Port size ALDU600-06 ALDU600-10 ALDU900-12 ALDU900-14 ALDU900-20 43 10 57 51 16 67 77 85 90 100 283 296 424 424 476 4 3 135 345 460 145 90 150 480 20 430 470 175 87.5 30 62.5 1 1 1 2 615 615 682 419.2 209 4 1 250 125 33.2 33.2

66 1/4 23.5 82.5 23 67.5 10.5 M4 x 0.7 Depth 4.5 PPA 22 29 0 38 40 31 125 66 1/4 23.5 84.5 27.5 M5 x 0.8 Depth 5 AL 24 28 2 43 48 36 112 100 76 3/8 50.5 27.5 68.5 M5 x 0.8 Depth 5 24 28 2 43 48 36 132 76 3/8 27.5 85.5 16 70.5 3.5 M5 x 0.8 Depth 5 24 28 2 43 48 36 132 76 3/8 27.5 87.5 20.5 M6 x 1 Depth 6 32 42 3 57 52 47 127 115 98 1/2 62.5 37 80.5 M6 x 1 Depth 6 32 42

IFW520 125 VAC 10 to 20 25 1.5 or less 5 5 1.5 0.7 4 4 2.5 1.3 IFW550 250 VAC 20 to 50 60 3 or less 5 5 1 0.5 4 4 1.5 0.8 Note) Hysteresis is the flow rate that is necessary for moving the microswitch from the operation position (ON signal) to the return position (OFF signal). 8 VDC 7 5 3 3 5 4 3 3 5 5 3 3 4 4 3 3 14 VDC 30 VDC 5 5 3 3 4 4 3 3 125 VDC 0.4 0.4 0.1 0.1 0.4 0.4 0.1 0.1 250 VDC