Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Specification: Built-in magnet, Support bracket: Through-hole
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Specification: Built-in magnet, Support bracket: Through-hole
The CS1 air cylinder offers 3 bore sizes (125, 140 & 160mm), 7 mounting options, and is auto switch capable. Other options include rod boots & cushions. Double acting, single rod, low friction; Available with Rc, NPT or G port threads; Bore size (mm): 125, 140, 160; Auto switch capable; Variety of lead wires or prewired connectors
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Specification: Without built-in magnet, Support bracket: Through-hole
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Specification: Without built-in magnet, Support bracket: Through-hole
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Specification: Without built-in magnet, Support bracket: Through-hole
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Specification: Without built-in magnet, Support bracket: Through-hole
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches: Without auto
15.2 64.4 8.2 45.8 18 60 AS2051F-07T 1/4" 15.5 7 1.5 13.2 54.4 7.1 35.7 17 33 20.6 9.5 1.5 AS3001F-10T 10 18.5 71.6 9.8 47.3 21 64 AS2051F-09T 5/16" 15.2 59.8 8.1 36.7 18 36 AS3001F-12T 12 20.9 76 11 48.5 22 68 AS3001F-07T 1/4" 13.2 59 7.4 45.2 17 56 AS4001F-10T 10 18.5 55.4 21 77.7 121 AS3001F-09T 5/16" 20.6 9.5 1.5 15.2 64.4 8.2 46 18 60 27.6 12 11.3 1.5 AS4001F-12T 12 20.9 82.1 56.4 22 125
Basic model reservoirs are capable of handling both liquid and gas applications from 29.92" Hg to 125-PSI. We also offer optional porting, float switches and siphon tubes in various sizes, for either the half liter or one liter reservoir canister.
Bore size (mm) Standard stroke (mm) Maximum manufacturable stroke (mm) 10 15, 30, 45, 60, 75, 100, 125, 150 400 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 400 Symbol Specifications -XAl Change of rod end shape -XC3 Special port location -XC9 Adjustable stroke cylinder/Adjustable retraction type Note 1) Manufacture of intermediate strokes at 1 mm intervals is possible.
Model Gripping force per finger Gripping force Note 1) Open/ Close stroke (Both sides) mm Bore size mm 10 16 20 25 Note 2) Weight g Model External Internal 60 125 250 455 4 6 10 14 17 40 66 104 9.8 30 42 65 11-MHZ2-10D 11-MHZ2-16D 11-MHZ2-20D 11-MHZ2-25D In-line electrical entry Lead wire type Explanatory drawing L Note 1) Values based on pressure of 0.5 MPa, gripping point L = 20 mm, at
Bore size CS1, CS2 series Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm MB, CA2 series Pressure 0.5 MPa Load ratio 50% Stroke 500 mm Average speed [mm/s] Series 40 50 63 80 100 125 140 160 180 200 250 1100 1000 900 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal VQ4100--03 VQ4101--03 1100 1000 900 800 700 600 500 400 300 200 100 0 VQ5100--04 VQ5101--04 Values at extension