SMC Corporation of America
Elite Part Number Search
Search Results "CLA2D40TN-200-P"

290 2.5 1 104 1 1/4 110 100 45 265 380 4.3 1 1/2 144 150 128 52 299 430 6.8 2 2 1/2 175 200 157 70 387 540 17.5 3 520

W C D FH FH V (Element removal dimension) HOW L M 4 x J A (mm) A B C D E F G H I J K L M N O P Q R Model FH990-04 FH990-06 FH990-08 FH990-10 FH990-12 FH990-16 FH991-20 FH991-24 FH991-28 FH991-32 1/2B M10 x 1.5 Thread depth 22 M10 x 1.5 Thread depth 22 1B 150 75 80 164 112 40 40 52.4 26.2 22.2 47.6 16.5 6 16.5 3/4B 1B M12 x 1.75 Thread depth 23 M12 x 1.75 Thread depth 23 1 1/2B 200 110 95

0.6 MA Gripping point Pressure P (MPa) Pressure P (MPa) DWorkpiece should be held at a point within the range of overhanging distance (H) for a given pressure indicated in the tables on the right.

Pressure P (MPa) Pressure P (MPa) Workpiece should be held at a point within the range of overhanging distance (H) for a given pressure indicated in the tables on the right.

-25D MHW2-32D MHW2-40D MHW2-50D 40 MHY2-10D MHY2-16D MHY2-20D MHY2-25D Gripping point 100 30 20 50 10 0.4 0.5 0.6 0.7 0 0 0.1 0.2 0.3 0.1 0.2 0.4 0.5 0.3 0.6 Gripping point Pressure P (MPa) Pressure P (MPa) Workpiece should be held at a point within the range of overhanging distance (H) for a given pressure indicated in the tables on the right.

, 250, 300, 350, 400, 450, 500 Replacement Parts: Seal Kits 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 Bore size (mm) Contents Kit No. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 40 50 63 80 100 CA2Y40-PS Rod seal 1 pc.

JIS symbol Minimum Operating Pressure Unit: MPa Bore size (mm) Minimum operating pressure 20 25 32 40 50 63 80 100 0.02 0.01 Standard Stroke Table Replacement Parts: Seal Kits Bore size (mm) Bore size (mm) 20 25, 32, 40, 50, 63, 80, 100 Standard stroke (mm) Note 1) Contents Kit No. 25, 50, 75, 100, 125, 150, 200 25, 50, 75, 100, 125, 150, 200, 250, 300 20 25 32 40 50 63 80 100 CG1Y20-PS CG1Y25

Ordering example (Example) Series VXP22, 32A Flange, 200 VAC, DIN terminal (Part no.) VXP2272-32-2D Made to Order Specifications Splashproof Specifications ( ) Based on JIS C 0920 Based on IEC529IP-X4 VXP Model Port size Electrical entry X36 DIN terminal or class H coil not available. 17-3-47 6 The VX series will be revised shortly.

Pressure Control Equipment Specifications 0 to 1 MPa Rated pressure range Output Specifications 0.1 to 1 MPa Set pressure range NPN open collector output 1.5 MPa Withstand pressure Max. 30 V, 80 mA Residual voltage 1 V or less 0.01 MPa Set pressure resolution 12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection) Power supply voltage Brown DC (+) 55 mA or less (at

operating tensile and compressive force (N) Allowable eccentricity (Umm) Rotating angle Basic type Standard/Thread nominal size JC20-8-125 JC30-10-125 JC40-14-150 JC63-18-150 0.5 0.5 0.75 1 300 800 1250 3100 M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 20 25/32 40 50/63 5 Semi-standard/Thread nominal size JC20-8-100 JC25-10-150 JC32-10-100 JC40-12-125 JC40-12-150 JC40-12-175 JC50-16-150 JC63-16-200

Pressure Control Equipment Specifications 0 to 1 MPa Rated pressure range Output Specifications 0.1 to 1 MPa Set pressure range NPN open collector output 1.5 MPa Withstand pressure Max. 30 V, 80 mA Residual voltage 1 V or less 0.01 MPa Set pressure resolution 12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection) Power supply voltage Brown DC (+) 55 mA or less (at

Note 4) When ordering the body only, select the symbol from to respectively. 2020 PVQ Specifications VEF VEP Rated pressure range Display/Set pressure range Withstand pressure Display/Minimum setting unit Applicable fluid Power supply voltage Current consumption Switch output 0 to 1 MPa 0.1 to 1 MPa 1.5 MPa 0.01 MPa (Air, Non-corrosive gas, Non-flammable gas) 12 to 24 VDC 10%, Ripple (p-p

Note 4) When ordering the body only, select the symbol from to respectively. 2020 ITVX Specifications PVQ Rated pressure range Display/Set pressure range Withstand pressure Display/Minimum setting unit Applicable fluid Power supply voltage Current consumption Switch output 0 to 1 MPa 0.1 to 1 MPa 1.5 MPa 0.01 MPa (Air, Non-corrosive gas, Non-flammable gas) 12 to 24 VDC 10%, Ripple (p-p)

(REFRIGERANT) IDF60-20) W R 0001 (2018 4 ) W R 0001 2018 2019 2020 2021 W X y Z 1 2 3 4 o P Q R o 1 Z 12 A Z IDF60/70/80/90 Series 1-5 IDX-OM-W093 1.3 HFC 1-5 IDF60/70/80/90 Series 1-6 IDX-OM-W093 1.4 / 1 1.5 () IDF60/70/80/90 Series 1-7 IDX-OM-W093 IDF60/70/80/90 Series 1-8 IDX-OM-W093 2 2.1 IN OUT (ONOFF ) 6-4 6-4 IDF60,70,80,90-20 IDF60,70,80,90-30 AC200V AC200V L1 L2

PLC H.T. ) Enable (SC_MonSs) 1 Disable Enable 2 1 2 (OC_Mon) Disable Enable (Inrush) 100msec 3 Disable 0.1 ms 1.0 ms 4 (Filter_T) 1.0 ms 10 ms 20 ms 1.0 ms 15 ms 5 (SigExt_T) 15 ms 100 ms 200 ms Enable Val165000 4 ON 3 ON/OFF (Counter) 6 Disable 1(EX600-DXPC1EX600-DXNC1) 22 OFF 0.5 mA ()OFF 0.5 mA 3 OFF 0.5 mA 31 4x1000 -54No.EX-OMN0027CN-D No. (H.T.

Timing of Wireless Communication 20 / 40 / 100/ 200 / 500 / 1,000 / 2,000 / 5,000 msec 500 msec Activated only when protocol V.2.0 is used If wireless communication (including retries) does not succeed due to obstacles or for other reasons, it is judged to have failed after a set amount of time and disconnected. Afterwards, the Base and the Remote are reconnected.

F H J L N P R Option Code Specification Standard (Cv: 0.06) High flow (Cv: 0.12) No code HF O-ring material 1) Not available for material code B.

Grease pack part no.: GR-S-010 (10 g) 72 Compact Cylinder/Large Bore Size: Double Acting, Single Rod Series CQ2 Replacement Procedure is 125, 140, 160 180, 200 P.290 Construction Standard Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !2 !3 !

Description Material AS800 AS900 y u i JIS B 2401 P-7 JIS B 2401 P-7 AQ NBR O-ring u O-ring O-ring Spring NBR NBR Stainless steel JIS B 2401 P-12 JIS B 2401 G-50 14115 JIS B 2401 P-16 JIS B 2401 G-65 14124 JIS B 2401 P-48 JIS B 2401 P-38 NBR O-ring ASV i AK ASS Dimensions: AS420/500/600 Dimensions: AS800/900 ASR ASF 2-Port size 2-Port size Dimensions Dimensions L1 L2 L4 Min.

1209, 1210 P. 1204 to 1206 P. 1204 to 1206 P. 1207, 1208 P. 1211, 1212 Buffer stroke Pad dia. 40 50 63 80 100 125 Buffer stroke (mm) 25 50 75 100 Pad Material and Characteristics Characteristics Base resistance Acid resistance Weatherability Ozone resistance Abrasion resistance Waterproof Solvent resistance (Benzene, toluene) Oil resistance benzol Oil resistance gasoline Operating temperature