(Use an auto switch rated 24V DC, with a minimum amperage capacity of 10mA.) q q q w w w e e e r (Unit: N) Bore size (mm) 40 50 63 80 100 Operation r Min. sensing weight 26 40 62 100 160 Warning Back-up of the balance pressure data The balance pressure data is backed up by the controller for approximately 5 minutes during a power outage or when the power supply has been turned OFF.
The additional air blow can be set to continuous or pulse (50/100 ms intervals). Ionizer Additional air blow Air blow Ionized air 497 ZVB Series Dimensions C B D A C B A D F E [ZVB20] F E [ZVB40] Model A B C D D Note 1) E F F Note 2) ZVB20 211 202 212 310 351 210 297 341 ZVB40 248 392 298 349 390 400 384 428 Note 1) Dimension D is the overall height including the knob of the regulator.
|vF3l3O (B) (A) ' 0 1 c 2 Clo6td C.l49r rd d#{Ft ffi# E I S E 2 {R2XPXB1) Low power consumption -1.8WDc (F2)(P)(F1l NVF3S3O Exh.Bt C.ii.. i{VF3,(3O (B) (A) c1 c2 ryffTfl-TTrl,* Er\llt'lll/'Es) EI SE2 Pr.aqa ConL. NVF353O f l Operating prs6sur range 2 pGiEon singb 20 -129 PSI S(1.5 -gkgF) 2 pssition double-15-128 P$l (1 -gkgflcm'?)
8 9 A B C D E F 1 4.1 + *S2 S1 DC24V MADE IN JAPAN 2 3 4 (48.5) (50) 133 10.5 10.5 5.1 4.5 5 5 Models Output unit can be used for mixed connection with PCW series.
75st Load weight m(kg) Load weight m(kg) 40 50 100 Larger than 50st 50st 25st 30 25, 50st 20 50 40 10 30 5 4 3 2 20 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 304050 100 200 300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) Allowable side load F(N) 1N: Approx. 0. 102kgf F Stroke (mm) Bore size (mm) Model 25 50 75 100 125 150 175 200 MGTM 140 151 162 176 193 212 178 204 63
Description Material AMD150 AMD250 AMD350 AMD550 AMD650 AMD850 Glass fiber, Others Element assembly AMD-EL150 AMD-EL450 AMD-EL250 AMD-EL350 AMD-EL550 AMD-EL650 AMD-EL850 r Element assembly: With gasket and O-ring AMD800 to 1000 HA AT ID Component Parts AMG Model AMD800/900/1000 SGP-E, SS400 SGP-E, SS400 AMD801/901 Note No.
Accumulated pulse output P ON OFF Output mode OUT1 50 msec ON n OFF Note1) Note 1) Output mode is set to inverted output when shipped from factory.
Unit: mm Piston speed (mm/s) Lock style 50 100 300 500 In terms of specific load conditions, the allowable kinetic energy indicated in the table above is equivalent to a 50% load ratio at 0.5MPa, and a piston speed of 300mm/sec.
/60 Hz 200 VAC, 50/60 Hz 110 to 120 VAC, 50/60 Hz 220 VAC, 50/60Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz Other Manual override/Classification 1 2 3 4 5 6 7 9 Electrical entry Non-locking push type (Flush) Non-locking push type (Extended) Locking type (Tool required) Nil A B Grommet Grommet terminal Conduit terminal DIN terminal G E T D Light/Surge voltage suppressor None Nil DIN terminal (Without
(For details, refer to catalog on page 22.) 17 Series SYJ500 Construction c f a e b d c f a e b d N.C. N.O.
locations) Rc,G,NPT1/8 Finger closing port 2 x M5 x 0.8 Vacuum port Rc,G,NPT1/8 Finger opening port H 32.2 4 x M10 x 1.5 (Piston rod thread and rack thread) 14.5 11 16 20 20 16 14 1 32.5 26 26 O S 30 K 32 68 (100) 40 32 32 15 15 4 4 15 50 When open F 24 24 4 x M10 x 1.5 through (Thread for mounting attachment) 70 When open G (mm) J 56 104 148 H 272 370 454 G 220 318 402 F 150 198 242 E 60
NBR JIS B2401G35 1 pc. u 4.6-30 Series AMF Dimensions: AMF150 to AMF350 M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 146 167 167 198 198 I 56 66 66 80 80 J 15 20 17 22 19 K 5 8 8 8 8 L 9 12 12 14 14 N 35 40 40 50 50 O 54 66 66 80 80 P 70 84 84 100 100 Q 26 28 28 34 34 R 4.5 5 5 5 5 S 1.6 2.0 2.0 2.3 2.3 1/8, 1/4,3/8 1/4, 3/8 5.5 6 6 7 7 139 152 158 184
Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage Lead wire length 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Electrical entry G H L LN LO M MN MO W0 Grommet, 300 mm lead wire Grommet, 600 mm lead wire
S Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R Lead wire length U 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.
-f.F F ", "I , H I' f.'5., I1tJ F E Rod end without ~ H S R thread , I Z oG H K l MM 1 s I z..q sst I lost IS" , 5" 16!J. IS'" IN 1 5" lOst ~ 15s1 ' A ... B C E F 15 12 ' 27 31 7 16.5 22.5 29 19 14 4.2 M5 x O.8 i M22 x 1.5 I 20 23.5 29.5 36 5 , 37.5 43.5 50 ' 6 'a~e size ' .rom) .
6 e @1 @1 e tValve guide tValve guide Working principle (For IR2000) When the setting knob is turned, the nozzle is closed by the flapper allowing the supply air that flows in from the upstream side to pass through the fixed throttle.
C E E (KF flange) Fd (K flange) Fn D H B A G A Unit: mm Model A B C D E Fn Fd G H XLA-16-2 40 108 38 20 30 17 44 XLA-25-2 50 121 48 27 12 40 26 44 XLA-40-2 65 171 66 39 11 55 41 67 XLA-50-2 70 185 79 46 11 75 52 72 XLA-63-2 88 212 100 55 11 87 95 70 76 XLA-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMS0001-B 6.
Air operated, External pilot valve 2 port 0 to 1 Pilot pressure: 0.1 to 0.7 0 to 0.97 Pilot pressure: 0.1 to 0.7 Cylinder operated by external pilot air 7, 15, 20, 25, 32, 40, 50, 65, 80 VNC 1/8 to 3B 17-4-21 Single unit N.C./N.O. 7, 15, 20, 25, 32, 40, 50 1/8 to 2 (2B) 17-4-37 VND Single unit N.C.
1 e !3 !4 o !0 !1 !2 e !3 !4 !5 !2 q !5 q t t r u u i i r y y w !6 w Meter-in type Meter-out type Meter-out type Meter-in type Seal method: Face seal For G thread e o !3 !1 !0 !4 !2 !5 q t u i r y !7 w Meter-in type Meter-out type Component Parts No.
5 Dew Point Conversion Chart 60 50 40 30 Pressure dew point C 20 10 1.5MPa 1.3MPa 1.1MPa 0.9MPa 0.7MPa 0.5MPa 0.3MPa 0.1MPa Atmospheric pressure 0 -40 -30 -20 -10 -60 -50 -60 -50 -40 -30 -20 -10 0 10 20 30 Atmospheric pressure dew point C 14-18-10 11 Series IDUS/IDFS Specific Product Precautions 1 Be sure to read before handling.