Size SCFM 50 PSI 60 PSI 70 PSI 80 PSI 90 PSI 100 PSI 110 PSI 1/2" ID 20 1.8 1.3 1 0.9 0.8 0.7 0.6 30 5 4 3.4 2.8 2.4 2.3 2 40 10.1 8.4 7 6 5.4 4.8 4.3 50 18.1 14.8 12.4 10.8 9.5 8.4 7.6 60 23.4 20 17.4 14.8 13.3 12 70 28.4 25.2 22 19.3 17.6 80 34.6 30.5 27.2 24.6 3/4" ID 20 0.4 0.3 0.2 0.2 0.2 0.2 0.1 30 0.8 0.6 0.5 0.5 0.4 0.4 0.3 40 1.5 1.2 0.9 0.8 0.7 0.6 0.5 50 2.4 1.9 1.5 1.3 1.1 1 0.9

Size SCFM 50 PSI 60 PSI 70 PSI 80 PSI 90 PSI 100 PSI 110 PSI 1/2" ID 20 1.8 1.3 1 0.9 0.8 0.7 0.6 30 5 4 3.4 2.8 2.4 2.3 2 40 10.1 8.4 7 6 5.4 4.8 4.3 50 18.1 14.8 12.4 10.8 9.5 8.4 7.6 60 23.4 20 17.4 14.8 13.3 12 70 28.4 25.2 22 19.3 17.6 80 34.6 30.5 27.2 24.6 3/4" ID 20 0.4 0.3 0.2 0.2 0.2 0.2 0.1 30 0.8 0.6 0.5 0.5 0.4 0.4 0.3 40 1.5 1.2 0.9 0.8 0.7 0.6 0.5 50 2.4 1.9 1.5 1.3 1.1 1 0.9

60 100 VAC, Hz 200 VAC, Hz 110 VAC, Hz 220 VAC, Hz 1 2 3 VQ Light/Surge voltage suppressor 50 60 50 60 Nil None 50 60 4 VKF With surge voltage suppressor (Grommet type is only available.)

Hz), 3-phase 200 to 230 VAC (60 Hz) -20 3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -20 3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) Set temp. range 5 to 35C Set temp. range 5 to 35C Set temp. range 5 to 35C Temp. stability 0.1C Temp. stability 0.1C Temp

M ast er Pow er SU P. ( D C24V) PRO FI BU SD P Sl ave1 O t her D P equi pm ent Sl ave2 O t her D P equi pm ent The pressure proportional to the signal on the second side is obtained.

Double acting, single rod cylinder w/lock, Mounting: basic, axial foot, rod flange, head flange, single clevis, double clevis, center trunnion, Bore sizes (mm): 40, 50, 63, 80, 100, Strokes up to 1500mm (depending on bore size & mounting), Auto switch capable, Power Lock Cylinder, CNA2, TIE ROD CYLINDER W/LOCK, 0.00000 lb

Style: Pressure Switch, Body Size: 50 (AC40-06), Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: 0.5m, Pressure Unit of the Scale Plate: MPa, Body Type: Standard

Magnet: D (Built-in), Mounting: B (Basic Style), Style: Aluminum Tube, Bore Size: 50mm, Thread: TN (NPT), Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Magnet: D (Built-in), Mounting: F (Front Flange), Style: Aluminum Tube, Bore Size: 50mm, Thread: TN (NPT), Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Magnet: D (Built-in), Mounting: L (Axial Foot), Cushion: A (Non-lube Air Cushion), Bore Size: 25mm, Port Thread: TN (NPT), Stroke: 50mm, Rod Boot: None

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,