Size: 30mm, Thread Type: NPT 1/8, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Size: 50mm, Thread Type: NPT 1/8, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 30, Valves: Not Provided, Allowable Kinetic Energy(J): 0.805
Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 50, Valves: Not Provided, Allowable Kinetic Energy(J): 1.820
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Not Provided, Allowable Kinetic Energy(J): 0.294, Format: With internal shock absorber, Size: 50, Switch
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Valves: Not Provided, Allowable Kinetic Energy(J): 1.600, Format: With internal shock absorber, Size: 100, Switch
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 1 to Less than 3, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Tube Nominal Diameter: 6, Valves: Not Provided, Allowable Kinetic Energy(J): 0.001, Operating
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 3 to Less than 6, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): Less than 0.005, Tube Nominal Diameter: 10, Valves: Not Provided, Allowable Kinetic Energy(J): 0.002, Operating Pressure Range(MPa
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.005 to Less than 0.01, Tube Nominal Diameter: 12, Valves: Not Provided, Allowable Kinetic Energy(J): 0.006, Operating Pressure
Bearing Style: High Precision Type, Size: 20 mm, Shock Absorber: For Low Energy, Port Location: Standard 180°, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 3m, Number: -, Thread Type: -
Bearing Style: Basic Style, Size: 30 mm, Shock Absorber: For High Energy, Port Location: Standard 90°, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 3m, Number: -, Thread Type: -
Model: MSQ, Type: High Precision Type, Size: 1, Port Location: Front Port, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Model: MSQ, Precision: Basic, Size: 100, Suffix: Adjuster Bolt, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 3m, Number: -, Thread Type: -
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, "CYL, ACTUATOR, CY1S GUIDED CYLINDER, LD, 32MM CY1S DOUBLE-ACTING
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, "CYL, ACTUATOR, CY1S GUIDED CYLINDER, LD, 32MM CY1S DOUBLE-ACTING
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
Series CS2 air cylinder is a double acting, non-lube air cylinder. Aluminum die-cast is used for both the rod and head covers, which means a maximum weight reduction of approximately 50% *. This series is available in bore sizes 125mm, 140mm and 160mm with maximum strokes up to 1600mm *. Air cushions are standard on both ends. Other options include auto switches, rod boots, and Rc, NPT or
Bearing Type: L (Ball bushing bearing), Bore Size: 16mm, Port Type: Bore 12-16: M5x0.8; Bore 20-100: Rc, Stroke: 20mm, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: L (3m)