SMC Corporation of America
Elite Part Number Search
Search Results "HRS012-W-10-M"

10 8 16 10 12 12 8 10 10 41 5 8 31 5 15.5 25 to 300 25 22 17 32 12 10 16 10 12 12 8 10 10 46 6 8 34 5.5 19.5 25 to 400 32 24 22 38 16 14 19 11 13 13 8 10 10 53 8 9 40 7.5 21 25 to 500 40 24 24 41 18 16 21 12 17 17 11 16 16 54 10 11 48 7.5 21 25 to 500 (mm) Bore size (mm) LH LS LT LX LZ MM NA NB P S T V W X Y ZZ LD 20 25 121 5.5 40 55 M8 x 1.25 17 15 1/8 81 9.5 4.5 6.5 20 9 151 7 25 28 121

Furthermore, if the cable length exceeds 5 m, then it will decrease by up to 10% for every additional 5 m. (At 15 m: Reduced by up to 20%) 12. When checking the conductivity of the cable, be careful not to deform the connectors mating hole and terminals.

Load proportion is ((load weight x 9.8)/theoretical force) x 100% Conditions of Speed Chart System A B C D E F G Solenoid valve Speed controller AS420-04 AS500-06 AS600-10 AS600-10 AS800-12 AS900-14 AS900-20 Tubing diameter x Length SGP15A x 1 m SGP20A x 1 m SGP25A x 1 m SGP25A x 1 m SGP32A x 1 m SGP40A x 1 m SGP50A x 1 m Silencer AN40-04 AN500-06 AN600-10 AN600-10 AN700-12 AN800-14 AN900

W-AREA1 (-) (+) WAREA ON (mm) W 1W 2 WAREA ON *W 1W 2 PARA W 1=W 2=0 WAREA OFF) W-AREA2 W-AREA2 (-) (+) ORG Correct Link Offset () Sensor type Sensor type () Option 1 Option 1 () Undefine No. 11 Undefine No. 11 () Undefine No. 12 Undefine No. 12 () *1 -45- 10.3 () ORIG direction ORIG direction 12 1CW [CW] 2CCW [CCW] ORIG mode Return to origin mode 12 1[] 2[SW]

Click here for details Port size (Rc) 06 08 10 12 16 20 24 3/4 1 1 1/4 1 1/2 2 2 1/2 3 Differential pressure indication Nominal filtration 0 4 5 005 010 020 074 105 5 m 10 m 20 m 74 m 105 m None Differential pressure indicator Differential pressure indication switch Note) Note) N.C. and N.O. common Note) The paper elements for water-glycol or emulsion is 10 m only.

Onetouch fitting) N11 (3/8" Onetouch fitting) Port size A, B port Manifold base weight W (g) n: Stations W = 100n + 151 W = 79n + 127 W = 61n + 101 Note 1) For 10 stations or more (5 stations or more for the 53-SS5Y7), supply pressure to P port on both sides and exhaust from EA/EB port on both sides.

N lszo-oH /Pressure Center 5 GJ1.81(300) H:23.62(600) Leading wire length Manual ovorrido o (PE Port) w/filter ' r ' r ' 1 ' I : : : ' ' M type plug connector/Nv4t320-OM/Closd Center tMzi!

Nil (Example) M9NWV 1 m M (Example) M9NWVM 3 m L (Example) M9NWVL 5 m L (Example) M9NWVZ 536 Pin Clamp Cylinder Plate Cylinder Type Magnetic Field Resistant Auto Switch/Small Auto Switch Mounting C(L)KU32 Series Basic Specifications LOW type LOW type with lock Model C(L)KU32 Action Double acting Bore size [mm] Equivalent to 32 Cylinder stroke/Clamp stroke [mm] 12.5 (Without workpiece)/10

10 10 90 42 27 45 31 49 190 10 10 80 35 35 62 39 66 190 10 10 65 30 39 68 43 72 190 10 10 50 24 49 83 53 87 Operating angle m: Value of the operating range Lm of a single auto switch converted to an axial rotation angle.

Stroke (M) Buffer specification Symbol Stroke 20, 25 35, 50 10 10 mm V V 20 20 mm V V J Rotating K Non-rotating Specifications Pad diameter Buffer specification Stroke [mm] Tightening torque [Nm] Mounting Spring reactive force [N] At 0 stroke At full stroke 20, 25 J/K 10, 20 2.5 to 3.5 M10 x 1 1.0 3.0 35, 50 J/K 10, 20 6.5 to 7.5 M14 x 1 2.0 5.0 Precautions Be sure to read this before handling

PA/B 3.6 (0.2) A/BR 3.24 (0.18) Rc(PT)1/8: Rc(PT) 1/4: M5: PA/B 3.42 (0.19) A/BR 3.24 (0.18) PA/B 3.6 (0.2) A/BR 3.6 (0.2) C4: C8 : C4: Valve effective area mm2 (Cv factor) Note 2) C6: C10: C6: C8: Manifold base weight W (g) Note 3) W = 65.4n + m + 128.2 W = 13n + m + 36 W = 41.2n + m + 77.6 (n: Number of SUP/EXH blocks, m: DIN rail weight) Note 1) In cases such as when many valves are operated

4 6 8 10 12 3 5 10 17 25 2.8 6.5 14 24 34 9.3 11.6 15.2 18.5 21.7 33.5 37.1 53.3 63.6 70.2 2-Applicable tubing D Inch Size Weight (g) Effective area (mm2) D L M Model Applicable tubing O.D.

Coil specifications VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Coil insulation type Class B Power consumption DC VCA 2: 6.5 W, VCA 3: 8 W, VCA 4: 11.5 W VX3 50 Hz (1) VCA 2: 7.5 VA, VCA 3: 10 VA, VCA 4: 13 VA Apparent power AC VXA 60 Hz Note 1) Since AC coil

30 st or less Over 30 st A A Symbol Symbol DB DB Stroke Stroke Bore size (mm) 12 16 20 25 Bore size (mm) 12 16 20 25 50 st or less Over 50 Over 50 50 st or less 30 st or less Over 30 st 43 39 4 6 8 16 0 55 49 43 6 8 10 22 0 65 57 10 61.5 10 12 27 14.5 0 74 47 63.5 16 62 13 16 32 14.5 0 79.5 47.5 8-20-9 10 Series MGQ Bore Size 32 to 100: MGQM, MGQL 4-YY depth YL W + Stroke 4-NN through 4-MM

I1 = 0.03 x (0.02 + 0.01)/12 = 1.25 x 10-kgm I2 = 0.006 x (0.005 + 0.005)/12 + 0.006 x 0.007 = 0.32 x 10-kgm I = 1.25 x 10+ 0.32 x 10-6 I1 = m x (a + b)/12 I2 = m x (a + b)/12 + m x H I = I1 + I2 Inertial moment = 1.57 x 10-kgm Kinetic energy 6 1/2 x I x Allowable energy = 2 /t (: Terminal angular velocity) : Rotation angle (rad) 1/2 x 1.57 x 10-6 x (2 x ( /2)/0.2) Confirm that the load's

I1 = 0.03 x (0.02 + 0.01)/12 = 1.25 x 10-kgm I2 = 0.006 x (0.005 + 0.005)/12 + 0.006 x 0.007 = 0.32 x 10-kgm I = 1.25 x 10+ 0.32 x 10-6 I1 = m x (a + b)/12 I2 = m x (a + b)/12 + m x H I = I1 + I2 Inertial moment = 1.57 x 10-kgm Kinetic energy 6 1/2 x I x Allowable energy = 2 /t (: Terminal angular velocity) : Rotation angle (rad) 1/2 x 1.57 x 10-6 x (2 x ( /2)/0.2) Confirm that the load's

FD FG FL FX FZ M A A CD CL CU CW CX CZ RR T 32 40 50 63 59 65 148 5.8 11.2 6.6 52.5 30 112.4 57 72.5 71 5.5 69.5 8 48 56 65 34 139 161 10 151 14 20 18 36 10 57.5 71.5 65.5 7 11.2 6.6 33 158.4 64 79.5 78 5.5 76.5 8 54 62 72 40 185 209 10 199 14 22 18 36 10 64.5 195.2 59 83.5 78 8 14.7 9 39 173.4 79 95 6.6 9 67 76 89 50 202 235 14 221 20 28 22 44 14 76.5 215.7 71 94 91 91 97 9 16.2 11 46 177.4

Lead wire length symbols: 0.5 m Nil (Example) M9N 1 m M (Example) M9NM 3 m L (Example) M9NL 5 m Z (Example) M9NZ Note) When using the 2-color indicator type, please make the setting so that the indicator is lit in red to ensure the detection at the proper position of the air gripper. 530 MHR3/MDHR3 Series Rotary Actuated Air Gripper 3-Finger Type Model/Specifications Nominal size 15 10 Action

m P 0.1 x mcos + msin P 0.1 x m + m P D 1.6 x D 5.0 x D 5.0 x m m mv P Pv m mv P Pv Determination of allowable load mass & pressure Inclined operation (Refer to page 29) 1 Review of operating conditions Determination of load factor () = Load mass (m) Maximum allowable load (m max) + Static moment (M) Allowable static moment (Mmax)+ Dynamic moment (ME) Allowable dynamic moment