For the external pilot valve, an R should be attached to the valve and the manifold part number. (See the below.)
Inch Example: 25 = 0.25 (1/4) Inch Stroke Specify XI Dimension in inches Construction Type S T Y L E Pneumatic H Hydraulic S TA N D A R D S T R O K E O P T I O N O V E R S I Z E D R O D XB5 O P T I O N Inches Example: 04 = 4 Stroke When ordering an oversized rod, please order the following way to represent the rod size required.
The drain pipe must have a minimum pipe bore of 10 mm, and a maximum length of 5 m (when installing an optional auto-drain).
If the piston impacts the stroke end with excessive kinetic energy (values in Table 1 or more), an excessive impact will occur and this may cause damage to equipment. Table (1) Allowable Kinetic Energy At Piston Impact Unit: [J] Allowable kinetic energy 50 to 500mm/s 20 25 32 40 50 63 80 100 Piston speed 0.055 0.09 0.15 0.26 0.46 0.77 1.30 2.27 7-7-19
The cushion effect (smooth start-up, soft stop) cannot be obtained in an intermediate stop or return from an intermediate stop using an external stopper, etc. When using an intermediate stop considering the above information, implement measures to prevent particulate generation and set the operating pressure to no more than 0.3 MPa.
A 0.6 16 Do not operate with the stroke adjusting unit fixed in an intermediate position. When the stroke adjusting unit is fixed in an intermediate position, slippage can occur depending on the amount of energy released at the time of an impact. In such cases, the use of the adjusting bolt mounting brackets, available per made-toorder specifications -X416 and -X417, is recommended.
An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. 1.
Make sure to perform a periodic inspection of the pressure gauge when it is used by installing it between a solenoid valve and an actuator, etc. Sudden pressure changes could happen and the durability of the product could be reduced.
Type of actuation C (dm3/(sbar)) b Cv C (dm3/(sbar)) b 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) Cv P, EA, EB A, B 35 37 Single Double 2 position 0.44 0.61 0.16 0.64 0.45 0.18 0.46 0.13 0.47 0.43 0.48 0.13 Closed center Exhaust center Pressure center SA SYA320-M5 M5 x 0.8 0.42 0.47 0.13 0.47 (0.44) 0.41 (0.37) 0.13 (0.12) 3 position 39 VA 0.50 (0.41) 0.48 (0.35) 0.15 (0.11) 0.47 0.43 0.13 44 46
Secure the switch at an appropriate position with a flat head watchmakers screwdriver as indicated in Figure 3. Tightening torque: 0.05 to 0.1 Nm Second groove MRHQ 10, 16 3. Install the switch case, with a switch attached securely in the hole, in the direction indicated in Figure 1.
A B Table running accuracy (mm) The LG1 series provides a stainless steel frame (LG1TH) for customers who required rigidity with an extendable aluminum frame. Refer to page 41 for further details.
Inch Example: 25 = 0.25 (1/4) Inch Stroke Specify XI Dimension in inches Construction Type S T Y L E Pneumatic H Hydraulic S TA N D A R D S T R O K E O P T I O N O V E R S I Z E D R O D XB5 O P T I O N Inches Example: 04 = 4 Stroke When ordering an oversized rod, please order the following way to represent the rod size required.
Note 5) The system accuracy when combined with an applicable flow sensor.
A 0.6 16 Do not operate with the stroke adjusting unit fixed in an intermediate position. When the stroke adjusting unit is fixed in an intermediate position, slippage can occur depending on the amount of energy released at the time of an impact. In such cases, the use of the adjusting bolt mounting brackets, available per made-toorder specifications -X416 and -X417, is recommended.
Failure to observe this procedure could damage the handle or cause the secondary pressure to fluctuate. 30 Maintenance Warning 1 Make sure to perform a periodic inspection of the pressure gauge when it is used by installing it between a solenoid valve and an actuator, etc.
For the external pilot valve, an "R" should be attached to the valve and the manifold part number.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
The figure a seal vent $MC PneumatICS' unique figure 8 seal incorporales vents that allow pressufized air to flow into an Integrated cavity forcing the seal firmly against the opposite side 01 the piston seal groove creating a much tighter, more positive barrier against leakage.