SMC Corporation of America
Elite Part Number Search
Search Results "HRSH100-AN-40-A"

Block off the heat with a cover, etc. 5. Do not use in locations where static electric charges will be a problem. Consult SMC regarding use in this kind of environment. 6. Do not use in locations where spatter occurs. There is a danger of spatter causing a fire.

Block off the heat with a cover, etc. 5. Do not use in locations where static electric charges will be a problem. Consult SMC regarding use in this kind of environment. 6. Do not use in locations where spatter occurs. There is a danger of spatter causing a fire.

A wiring example of multiple controllers (3 pcs.) connected to an upper level device is shown below.

A wireless slave can then be registered to the dummy area at a later time, without having to change the I/O map Dummy slave E Export Function to save the configured values of a wireless unit by exporting them to a PC. F Fieldbus Network protocol to establish digital communication between an automated industrial system such as a measurement tool or manipulation tool and a PLC.

Do not Do not use the product in a place where static electricity is a problem. Otherwise failure or malfunction of the system can result. Do not If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product for proper operation. Otherwise malfunction can result, causing an accident.

(Ex. : 1:Normal) C o n t r o l O p e r a t i o n M O D E < 1 : N o r m a l Function : Selects control operation mode among them below 0 : Stop of control (Pump Stop) 1 : Normal (normal control operation) 2 : AT (auto tuning) 3 : Learning control (Learn) 4 : External tune control (External) When a learning control and an external tuning control are selected, measurement temperature (#2) of

Operation of an auto switch may become unstable by the effect of a magnetic substance. There is no problem if a magnetic substance is close to any side where an auto switch is not mounted.

When the product is Unevenness of a workpiece or base mounted on the body of the product may cause play in the guide and an increase in the sliding resistance. 10. When mounting the product, keep a 40 mm or longer diameter for bends in the cable. 11. Do not hit the table with the workpiece in the positioning operation and positioning range. 12.

Therefore, even within a given allowable kinetic energy level, there is an upper limit to the amount of the load that can be sustained. 11.Use a balanced circuit in which lurching of the cylinder is prevented.

Using an electronic type pressure gauge is recommended, depending on the situation. 727 ARM11B Series Construction OUT IN SMC K P C U O S H L e t A-A A w y r i !0 u !1 q SMC o A Component Parts Description Replacement Parts Part no. Material Note Material No. Description No.

size A C D E G H J 1(P) 2(A) 3(R) AV2000-m02-1 to 4G(Z)m-A 1/4 1/4 1/4 66 47 24.5 40 33 Width across flats 22 30 AV2000-m02-5 to 6G(Z)m-A AV3000-m03-1 to 4G(Z)m-A 3/8 3/8 3/8 76 50 29.5 40 38 Width across flats 24 35 AV3000-m03-5 to 6G(Z)m-A AV4000-m04-1 to 4G(Z)m-A 1/2 1/2 1/2 98 56 39.5 52 49 Width across flats 30 33 AV4000-m04-5 to 6G(Z)m-A AV5000-m06, 10-1 to 4G(Z)m-A 3/4, 1 3/4, 1 3/

Block off the heat with a cover, etc. 5. Do not use in locations where static electric charges will be a problem. Consult SMC regarding use in this kind of environment. 6. Do not use in locations where spatter occurs. There is a danger of spatter causing a fire.

Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.

External pilot type R (2) B C A Note 1) Option Note 2) For details about external pilot specifications, refer to page 4-14-40.

1 Stainless Steel Cylinder Series CJ5-S Series CG5-S 10, 16 20, 25, 32, 40, 50, 63, 80, 100 Applicable for use in an environment with water splashing such as food processing, etc. RE A B REC Uses grease for food processing machines that meets FDA (U.S.

1 Stainless Steel Cylinder Series CJ5-S Series CG5-S 10, 16 20, 25, 32, 40, 50, 63, 80, 100 Applicable for use in an environment with water splashing such as food processing, etc. RE A B REC Uses grease for food processing machines that meets FDA (U.S.

Auto switch mounting band CLK2 CLKG Auto switch model Bore size (mm) 40 50 63 CKQ CLKQ D-M9 D-M9W D-A9 CK CLK BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) CKQ D-M9ANote 2) BMA3-040S (A set of a, b, c, e) BMA3-050S (A set of a, b, c, e) BMA3-063S (A set of a, b, c, e) Auto switch Switch bracket (Resin) Transparent (Nylon)Note 1) d e White (PBT

For 1/8 For C6/N7 1-5-45 46 Series SYJ5000 C4 N3 Type 43: Side Ported/SS5YJ3-43Stations [ ]: AC Grommet (G) Approx. 300 (Lead wire length) L1 L2 4.5 Manual override 2-5.5 (For mounting) 12 1/8 (P, R port) 62.7 [64.9] 62.1 [64.3] 40.6 (DIN 41.8) 40 (DIN: 41.2) 87.2 [91.6] 103.2 [107.6] R P P R B B B B B 17.5 11.4 36.9 20.3 A A A A A 3 (DIN: 4.2) 1 (4.4) Courtesy of Steven Engineering, Inc

Insufficient flatness of a workpiece or bracket mounted on the mounting surface or plate of the cylinder and other parts can cause defective operation and an increase in the sliding resistance. 40 32 25 10 20 Load mass (kg) 6.

For installation and removal, use an appropriate pair of pliers (tool for installing a type C snap ring). 2. Even if a proper plier (tool for installing type C snap ring) is used, it is likely to inflict damage to a human body or peripheral equipment, as a snap ring may be flown out of the tip of a plier (tool for installing a type C snap ring).