SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-L-M-01-WY"

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: C01 (Rc1/8), Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: C01 (Rc1/8), Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

Load proportion is ((load weight x 9.8)/theoretical force) x 100% Conditions of Speed Chart System A B C D E F G Solenoid valve Speed controller AS420-04 AS500-06 AS600-10 AS600-10 AS800-12 AS900-14 AS900-20 Tubing diameter x Length SGP15A x 1 m SGP20A x 1 m SGP25A x 1 m SGP25A x 1 m SGP32A x 1 m SGP40A x 1 m SGP50A x 1 m Silencer AN40-04 AN500-06 AN600-10 AN600-10 AN700-12 AN800-14 AN900

Holding point L (mm) 120 80 160 200 20 40 60 Holding point L (mm) 80 0 20 40 60 Holding point L (mm) 80 100 120 MHW2-25D MHW2-40D MHZ2 160 50 Pressure 0.7MPa Pressure 0.7MPa 140 MHZJ2 0.6 0.6 40 120 Holding force (N) Holding force (N) 0.5 0.5 MHQ 100 30 0.4 0.4 80 0.3 MHL2 0.3 20 60 0.2 0.2 40 10 MHR 20 0 20 40 60 Holding point L (mm) 100 80 20 40 60 Holding point L (mm) 80 100 120 140 160

190 13 13 16 16 19 55 66 72 92 98 63 76 76 90 90 7.5 4 4 5 5 63 76 76 90 90 10 10 10 10 10 AMF150 AMF250 1/2 3/8, 1/2 AMF350 3/4 AMF150SAME, #1 AMF250SAME, #2 AMF350SAME, #3 4.6-31 Odor Removal Filter Series AMF Dimensions: AMF450 to AMF850 HAl AT IDl AMG AFF AMl M Dimensions with mounting bracket Model Port size (Nominal size B) A H B C D E F G I 221 J 25 K 10 L 14 N 90 O 55 P 110 Q 50

Air-hydro cylinder: CA1lHl-l, CQ2lHl-l, CS1lHl-l, CM2lHl-l, CG1lHl-l(to 63), HC03-X1-lXl Air-hydro rotary actuator: CRA1 Hl-l wWhen determining the size of a converter based on the , do not select a converter bore that is too small for the cylinder's bore size because this will increase the oil level speed, causing the oil to blow out.

gauge G36-10-01 1MPa Description Part no.

ON OFF IN OUT R 7 Spacer L type bracket Spacer with L type bracket T type bracket Spacer with T type bracket Spacer with L type bracket Spacer with T type bracket T type bracket L type bracket L type bracket Spacer with L type bracket Applicable model T type bracket Spacer with T type bracket Applicable model Applicable model Model Y20T AV2000 B210T Y20L AV2000 AV2000 Y20 B210L Y30T AV3000

M-8 M-12 SMC Type of 2-Apr-01 SMC Quick Reference Auto Switch Chart with (PnP) M-8 (3 pin) & M-12 (4 pin) Connectors, Page 1/2 The above older MDB1 Direct Body Mount 32, 40, 50, 63, 80 & 100 Bore sizes (Auto Switch Spacer # BMP1-032 required) our new part # MHL, Direct Body Mount 10, 16, 20, 25, 32 & 40 Gripper Bore sizes -Y7PSDPC MHQG2 Direct Body Mount 32 & 40 Gripper Bore sizes MHS2/3/

&WEB -14- 3. 5mm B B B A A () A B 0 A B A mm B Nm A B MHM-16D1 2 10 6 1.5 5 MHM-25D1 3 14 8 5.2 5 MHM-32D1 3 14 8 5.2 5 MHM-50D1 5 24 17 42 5 -15- D(mm) L(mm) MHM-16D1 14 25 MHM-25D1 19 37 MHM-32D1 19 43 MHM-50D1 30 63 4. 2 1 n /WEB Best Pneumatics m () 0.5 ( ) 3 (NPN) 3 (PNP) IC 2 3 (NPN) IC 3 (PNP) 2 PLC 2 3 (PNP) 3 (NPN) IC (2 ) 2 1 0.5mM9NW 1m M M9NWM 3m L M9NWL 5m

When [M] is included in the controller model number (fixed SI units), set up the controller to display the units according to the table below. When [M] is not included in the controller model number (with unit conversion), the appropriate units label should be used from the table above. If the error cannot be reset after the above measures are taken, then please contact SMC.

When [M] is included in the controller model number the controller displays [S_J]. When [M] is not included in the controller model number the controller displays [S_F]. Hysteresis mode ON OFF Power on Specifications Outline with Dimensions (in mm) n_1 High pressure Wiring Normally closed mode Detects pressure displays values and performs switching.

Graph 2 Supply pressure: 0.5MPa Load weight M [kg], Stroke St [mm], Stroke time To [S], Average speed of cylinder Vm=St/To [mm/s] 1,000 Selection of cylinder Graph 1 Apply Vm (average speed) with Graph 1, and determine Vmax (Max. speed). 200 Graph 2 Apply M (load weight) with Graph 2 and Vmax determined with Graph 1, and determine cylinder size. 150 Load weight M (kg) 100 50 Graph 1 h=0.7

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated