How to Order Standard L 40 150 CM2Y L H7BW S 40 150 CDM2Y With auto switch Number of auto switches With auto switch (Built-in magnet) 2 pcs. 1 pc. n pcs.

How to Order S 2 B P H S4 200 LEY 63 A2 w y !0 i o e r t q u !1 !2 !3 !

(mm) 1 8 1 4 3 8 1 2 1 8 1 4 3 8 1 2 1(P) 1(P) M5 4 6 8 10 12 1(P) 1(P) M5 4 6 8 10 12 Applicable tubing O.D. (mm) Applicable tube O.D. (mm) Applicable tubing O.D.

Lube unit: Series ALDU Strainer Series INA Main line filter Series AFF Solenoid valve Metal seal Regulator Series AR Air cylinder Air tool Air dryer Series IDF How to read graph Solenoid valve Rubber seal With the flow rate set to 250 l/min(ANR) and the pressure differential set to 0.05MPa, by changing the flow rate to 3800 l/min(ANR) and 6000 l/min(ANR), the pressure differential will change

Normal operation Value clear Initial setting P.14 Adjust the zero point of atmospheric pressure. Detects and displays pressure and operates switch. Set "Output mode", "Response time" and "Auto/ Manual mode." Auto preset P.14 P.16 The pressure set point is calibrated automatically at the time of adsorption or primary pressure confirmation.

x 1.25 10 8 28 25.5 Q R T V Y N O P Bore size (mm) 12 20 M4 x 0.7 M5 x 0.8 47 7 53.5 22 7 5.5 M6 x 1 M5 x 0.8 50 15 62.5 36 5 For rod end nut accessory bracket, refer to page 658.

pulse multiplying factor denominator) PB09 VG2 Speed loop gain P, S PB10 VIC Speed integral compensation P, S PA08 ATU Auto tuning mode P, S PB11 VDC Speed differential compensation P, S PA09 RSP Auto tuning response P, S PB12 OVA Overshoot amount compensation P PA10 INP In-position range P PB13 NH1 Machine resonance suppression filter 1 P, S PB14 NHQ1 Notch shape selection 1 P, S PA11 TLP

8 x L counter bore J J A + Stroke M M Rod end male thread CHKDB20, 25 CHKDB32 to 100 Water resistant type S N g C B + Stroke h + Stroke A + Stroke Rod end male thread (mm) B C D E F G H J K L M P Q R A Bore size (mm) 20 51 43 8 12 10 M8 x 1.25 10 6 30 5.5 9.5 depth 5.4 43 1/8 16.5 6 25 53 45 8 14 12 M10 x 1.5 12 6 36 5.5 9.5 depth 5.4 49 1/8 17 8 32 61 51 10 18 14 M12 x 1.75 15 7 47 6.6

How to Order L 25 100 CG1Y Without auto switch L H7BW S 25 100 CDG1Y With auto switch Number of auto switches Built-in magnet 2 pcs. 1 pc. n pcs.

D M E T Plain washer K B + Stroke L M A + Stroke E 20, 25 Rod end male thread H1 Rod end nut Note 2) C1 X L1 Rod End Male Thread Bore size (mm) 12 16 20 25 (mm) C1 9 10 12 15 H1 M5 x 0.8 M6 x 1.0 L1 14 15.5 18.5 22.5 X 10.5 12 14 17.5 M8 x 1.25 M10 x 1.25 Basic Style (mm) Without auto switch With auto switch Bore size (mm) Stroke range (mm) A 25.5 25.5 29 32.5 C D E F H I K L M N OA OB Q

2-M5 x 0.8 (32: Rc 1/8) Rod end nut Rod End Nut/Accessory Material: Carbon steel Width across flats L 2P through Part no.

(Opposite side: Same) Data N (I) (L) (Z) W C (mm) A B C D E F G H I J K L M N OO NN P Model 2-5.5 through 2-M4 x 0.7 thread depth 6 2-M5 x 0.8 thread depth 7.5 2-M5 x 0.8 thread depth 8 CXS20 64 25 62 23 50 28 6 12 12 30 10 M6 x 1.0 x 18.5l 53 11.5 2-M5 x 0.8 2-9.5 counterbore depth 5.3 2-6.9 through CXS25 80 30 78 28 60 35 6 12 12 30 12 M6 x 1.0 x 18.5l 64 14 2-M6 x 1.0 2-11 counterbore

P+0.1 0.1 QCR = V x x 10 3 (1) P 0.1 (2) QCP = a x L x x 10 6 Formula QCR = Amount of air consumption of rotary table [L(ANR)] Qc2 = Qc x n x No. of actuators x Margin rate QCP = Amount of air consumption of tube or piping [L(ANR)] V = Inner volume of the rotary table [cm 3] Qc2 = Amount of exhaust air from a compressor [L/min (ANR)] n = Actuator oscillations per minute P = Operating pressure

A l l o w a b l e L o w e r T e m p . R a n g e Sets lower limit of temp. where the warning occurs. The difference between target temp. and lower limit temp. should be input. Function M O D E < 1 0 . 0 C [Tip] Status when temp. upper/lower limit alarm occurs. W R N P V < 2 5 . 6 C # 1 When temp. upper/lower limit alarm occurs, indicator WRN lights on.

AL SMC SMC SMC SMC SMC SMC 0.1 0.3 0.2 0.4 0.5 0.6 IS1000 MPa SMC SMC SMC K K K P P P C C C U U U O O O SMC SMC SMC SMC S S S L L L H H H MADE IN JAPAN K K K P P P C C C U U U O O O S S S L L L H H H Mixed manifold Mixed manifold Front handle/Bottom ported Front handle/Top ported Common exhaust type and individual exhaust type can be mounted on the same manifold base.

AL SMC SMC SMC SMC SMC SMC 0.1 0.3 0.2 0.4 0.5 0.6 IS1000 MPa SMC SMC SMC K K K P P P C C C U U U O O O SMC SMC SMC SMC S S S L L L H H H MADE IN JAPAN K K K P P P C C C U U U O O O S S S L L L H H H Mixed manifold Mixed manifold Front handle/Bottom ported Front handle/Top ported Common exhaust type and individual exhaust type can be mounted on the same manifold base.

SFB104-M5 0.1 q e t r w Max. flow rate line Inlet pressure Pressure drop MPa 0.3 MPa 0.01 0.1 MPa 0.7 MPa 0.001 0.5 MPa IN 0.0001 100 0.1 1 10 y Flow rate L/min (ANR) Description No.

AXT100-DS25015 030 050 L Terminal no.

: 10 Standard Piping 4-M3 x 0.5 thread depth 4.5 16 12 + Stroke 3.5 8 7.5 2-M5 x 0.8 thread depth 4 (Piping port) 28.5 8 Stroke 15 56 + Stroke 8 3.5 13 1 44.5 + Stroke M5 x 0.8 x 4 L (Hexagon socket head set screw) 4 16 8 + Stroke M8 x 1.25 x 7.5 L (Bolt holder) 1 40 33 0.2 33 0.2 20 42 8 8 3.4 through 6.5 counterbore with depth 5.5 (Opposite side: Same) 2-M3 x 0.5 through 6.5 2-M4 x 0.7