Valve power PWR(V) supervision Enable Disable Enable WARNING: If safe PWR(V) monitoring is required for the application or if PWR(V) diagnostic is disabled on the device PWR(V) failures must be managed externally by other means.
V V V V 28.8 8.5 21 10 9 8.5 9 81 Vacuum port (V port) Note 4) 107 (M5 x 0.8) Dimensions Note 1) The above dimensions are for ZZQ1-BSB.
1*2 gal/min 6*1*2 V V gal/min 7*1*2 V gal/min Port size Symbol Port size Applicable model LFE1 LFE2 LFE3 3 3/8 V 4 1/2 V 6 3/4 V 8 1 V *1 Options 4, 5, 6, and 7, which are not in SI units, are not for use in Japan due to the New Measurement Law. *2 Options 4, 5, 6, and 7 cannot be selected when the output specification is J or K.
/ sensors) 24 V (valves / loads) 0 V (valves / loads) FE 24 V (logic / sensors) 0 V (logic / sensors) 24 V (valves / loads) 0 V (valves / loads) FE BUS BUS Fig. 11-3 Block diagram of the EX245-DX1 74 No.EX##-OMY0004 12.
For example, when analogue output is 1 to 5 V, F.S. = 5 [V] 1 [V] = 4 [V]. (Reference: 1%F.S. = 4 [V] 1% = 0.04 [V]) F.S. (full span/ full scale) H Hysteresis The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.
4 mA 4.16 mA 20 mA E F G Voltage output (0 to 10 V) 1 0 V 0.10 V 10 V 1: The analogue output current from the connected equipment should be 20 A or less when selecting 0 to 10 V.
DO (n+1) 0 V DO (n) FE / Shield Output interface Output interface Short circuit Short circuit protection protection Output circuit / Output circuit / Bus interface Bus interface 24 V (logic / sensors) 0 V (logic / sensors) 24 V (valves / loads) 0 V (valves / loads) FE 24 V (logic / sensors) 0 V (logic / sensors) 24 V (valves / loads) 0 V (valves / loads) FE BUS BUS Fig. 12-3 EX245-DY1 79
circuit 5 V, 12 V 5 V With diagnostic output (2-color indicator) 100 V Grommet IC circuit 100 V or less B54 B64 100 V, 200 V Relay, PLC 12 V 2-wire 24 V 200 V or less C73C C80C Connector IC circuit 24 V or less B59W Grommet Diagnostic indication (2-color indicator) 1 Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance
D-Y7NW(V)/Y7PW(V)/Y7BW(V) D-Y7BAL BU-1 BU-1 BU-1 BU-1 A B A B
A I R C U S H I O N .Both Ends N .None H .Cap End R .Rod End *Note: Non Adjustable Cushions are available on units above 4Bore Please Consult P/A Customer Service **Note: Cushions not recommended for Strokes below 3 How To Order MT4 With Non Standard XI Dimension NCA1 T X46US (XI = Total Inches) T Specify XI Dimension in inches Construction Type S T Y L E O P T I O N O V E R S I Z E D R
A I R C U S H I O N .Both Ends N .None H .Cap End R .Rod End *Note: Non Adjustable Cushions are available on units above 4Bore Please Consult SMC Customer Service **Note: Cushions not recommended for Strokes below 3 How To Order MT4 With Non Standard XI Dimension NCA1 T X46US (XI = Total Inches) T Specify XI Dimension in inches Construction Type S T Y L E O P T I O N O V E R S I Z E D R
A96V A96 IC circuit 5 V Yes A72 A93V A90V A73C A80C A79W A72H A93 A90 Grommet 200 V 100 V 12 V IC circuit IC circuit No 5 V, 12 V 12 V 100 V or less Relay PLC 2-wire 24 V Yes No Connector 5 V, 12 V 24 V or less Grommet Yes Diagnostic indication (2-color display) Solid state auto switches marked with a are produced upon receipt of order.
[How to JOG] a) Change the mode to Remote mode in the main window. b) From the main window select View (V), select the Teaching window and select the JOG tab. Refer to section "4.1 (1-1-2) View (V)" for how to display the Teaching window.
For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V]x1% = 0.04[V]) The maximum measuring range or change in analogue output over the maximum measurement range. F.S. (Full span, Full scale) H The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.
not be detected v Ammonium ion (NH4+) [mg/L] 0.1 or less v Residual chlorine (Cl) [mg/L] 0.3 or less v Item Unit Standard value Influence Free carbon (CO2) [mg/L] 4.0 or less v Corrosion Scale generation *1 In the case of [Mcm], it will be 0.003 to 0.01.
Connector Grommet Diagnostic indication (2-color indication) 12 V 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Grommet 2-wire 12 V Connector Relay, PLC 24 V 3-wire (PNP) 3-wire (NPN) IC circuit Yes 5 V, 12 V Diagnostic indication (2-color indication) Grommet 2-wire 12 V Water resistant (2-color indication) 4-wire (NPN) 5 V, 12 V IC circuit With diagnostic output (2-color indication
12 V Relay, PLC Grommet Yes 24 V 3-wire (NPN) 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 3-wire (PNP) 2-wire 12 V Yes No Yes No 100 V Reed auto switch Relay, PLC IC circuit 100 V or less Grommet 24 V 2-wire 12 V 100 V, 200 V 200 V or less Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid
Black] Indicator light/Display method 23 2 Color Indicator Type Solid State Switches /Direct Mounting Type D-F9NW(V), D-F9PW(V), D-F9BW(V) Auto Switch Specifications Grommet D-F9W, D-F9 WV (with indicator light) D-F9NW Auto switch part no.