Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: Operation Manual
Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: None, Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration
Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
rod Double acting, Single rod, Non-rotating Nil W K Auto switch Nil Without auto switch (Built-in magnet) Mounting style Refer to the table below for auto switch symbol.
Features 2 Mechanically Jointed Rodless Cylinder with Protective Cover Series MY1W Slide Bearing Guide Type/Cam Follower Guide Type 16, 20, 25, 32, 40, 50, 63 How to Order Y7BW 300 25 MY1 M W K Number of auto switches Guide type Auto switch type 2 pcs. 1pc. "n" pcs.
Rod end male thread 20, 25 Rod end nut Rod End Male Thread Bore size (mm) 12 16 20 25 L1 X C1 9 10 12 15 H1 M5 x 0.8 M6 x 1.0 M8 x 1.25 M10 x 1.25 14 10.5 15.5 12 18.5 14 22.5 17.5 Basic Style A B A B Without auto switch With auto switch Bore size (mm) Stroke range (mm) 5ST C I N OB D K OA RA E L RB F M T H 10ST 5ST 10ST 5ST 10ST 5ST 10ST 12 16 20 25 M3 x 0.5 15.5 M4 x 0.7 6 8 7 12 32 38