SMC Corporation of America
Elite Part Number Search
Search Results "LVM10R4Y-5G1-1-Q"

Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance. Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C

Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance. Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C

Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance. Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PVDF, M6, Option: Bracket + Manual Override, Lead Wire Length: 1000mm, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PVDF, M6, Option: Bracket + Manual Override, Lead Wire Length: 600mm, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PVDF, M6, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PVDF, M6, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PVDF, M6, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: -

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: G (Plate: PFA; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1 (PVDF, M6), Option: 3 (Bracket + Manual Override), Lead Wire Length: 10 (1000mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: G (Plate: PFA; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1 (PVDF, M6), Option: 3 (Bracket + Manual Override), Lead Wire Length: 6 (600mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: G (Plate: PFA; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1 (PVDF, M6), Option: 3 (Bracket + Manual Override), Lead Wire Length: K (Plug Connector, 300mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: G (Plate: PFA; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1 (PVDF, M6), Option: 3 (Bracket + Manual Override), Lead Wire Length: KO (Plug Connector, w/o Connector)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: G (Plate: PFA; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 1 (PVDF, M6), Option: 3 (Bracket + Manual Override), Lead Wire Length: KZ (Plug Connector, 300mm)

1 !1 r r !2 !2 q q y !3 w y t w i t o i !0 u !0 o e !4 u Meter-in type Meter-out type e Seal method: Face seal For G thread Meter-in type Meter-out type !1 !2 r q w y t i o !0 u !5 e Meter-in type Meter-out type Component Parts No.

SY 3 5 1 0 0 1 q w r e t y u i o !0 !1 Base mounted q Series !

9 @0 @8 #4 $2 $3 $9 %2 ^0 ^7 Qty. 1 1 1 1 2 2 2 2 2 4 2 1 1 2 2 4 2 2 6 4 8 2 6 2 1 2 4 4 3 4 4 1 1 4 1 4 2 1 1 1 2 2 1 1 1 2 1 1 1 8 4 2 1 6 No. q w e r t y u i o !0 !1 !2 !3 !

M6 x 1 A8 M8 x 1 G J J 04 4 06 6 08 8 Model A B C D 2 E F G H J K L M Vacuum inlet direction q Pad dia.

Note Description SY940 M2: 0.16 Nm M3: 0.8 Nm M4: 1.4 Nm Aluminum die-casted 1 4 3 8 3 8 1 2 SY5000-27-1 (-Q) : SY7000-27-1 (-Q) : SY7000-27-2 (-Q) SY3000-27-1 (-Q) : SY9000-27-1 (-Q) : SY9000-27-2 (-Q) Sub-plate Note) 6 Pilot valve assembly Refer to How to Order Pilot Valve Assembly on page 130.

SYJ7000-22-1(-Q) SYJ7000-22-2(-Q) V111(T)No. 1 2 3 4 5 6 Aluminum die-casted 1/8 1/4 Body Piston plate End cover Piston Spool valve assembly Spool spring Sub-plate Note) 7 8 Pilot valve Note) Add suffix -Q for the CE-compliant product.

R 50 60 63 66 70 Q 40 R Q 58 R S 46 Q 95 R S 62 T U 46 56 56 W X 11 13 13 Y Normally closed Normally open VX212 VX222 VX232 VX210 VX220 VX220 VX230 VX230 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 1/4, 3/8 1/4, 3/8, 1/2 18 22 30 22 30 (76) (86) (93) 2, 3, 4.5 3, 4.5, 6 8, 10 3, 4.5, 6 8, 10 40 45 50 45 50 68 78 85 85 92 30 9 19.5 27 6 8 8 8 8 12.8 19.5 42.5 42.5 42.5 85 36 46 46 15 10.5 19