Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: PNP; OUT2: PNP, Temperature Sensor: Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: PNP; OUT2: PNP, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: PNP; OUT2: PNP, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate:
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM
Designed to work with fluids up to 90ºC, these switches incorporate a built-in temperature sensor so both flow and fluid temperature can be effectively monitored at the same time.
Designed to work with fluids up to 90ºC, these switches incorporate a built-in temperature sensor so both flow and fluid temperature can be effectively monitored at the same time.
Designed to work with fluids up to 90ºC, these switches incorporate a built-in temperature sensor so both flow and fluid temperature can be effectively monitored at the same time.
Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (without Lead Wire), Flow Switch Unit: G (Remote Sensor Unit; Instantaneous Flow: L/min, (gal/min); Accumulated Flow: None; Temp: °C (°F); Integrated Display: gal/min; Accumulated Flow: gal; Temp: °C)
Flow Switch Type: Remote Sensor Unit, Rated Flow Range: 5~40L/min, Return Unit: None, Thread: NPT, Port Size: 3/4, Flow Switch Output: Remote Sensor Unit; Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None, Temp. Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: without Lead Wire, Flow Switch Unit: Remote Sensor Unit; Instantaneous Flow: L/min, (gal/min); Accumulated Flow: None; Temp:
Twist selector (3 position) VM131-01-35 (R, B, G, Y) A VM151-01-35 (R, B, G, Y) A Panel mounting hole ON 45 T.T.
Note 1) Set the inlet pressure to at least 0.05 MPa higher than the set pressure. Note 2) Option B, G, H, M are not assembled and supplied loose at the time of shipment. Note 3) Assembly of a bracket and set nuts (applicable to the AR20(K)-B to AR40(K)-B).
Find the value of m max. at 300 mm/s in Graph (7) for m3. m M1 = m x g x L1 = 3 x 9.8 x 0.05 = 1.47 [Nm] 2. Static moment Investigate M1. Find the value of M2 max. at 300 mm/s in Graph (1). 2a =M1/M1 max =1.47/14 =0.105 M1 L1 M3 = m x g x L2 = 3 x 9.8 x 0.04 = 1.176 [Nm] m x g Investigate M3.
Test was performed at both energized and deenergized states in the axial direction and at the right angles to the main valve and armature.
exhaust center: VFS3400-F 3 position pressure center: VFS3500-F 3 position double check: VFS3600-F VFN 2-5.6 mounting hole 170.5 (3 position: 175) 2-5.6 mounting hole Light window At Fz 86.5 (3 position: 96.5) Pilot valve manual override Light window At Fz With direct manual override Pilot valve manual override With direct manual override G 1/2 electrical entry 5-Rc , 1 4 3 8 G 1/2 electrical
Seal kit includes a grease pack (40 and 50: 10 g, 63 and 80: 20 g, 100: 30 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) As for the center trunnion type, it is very difficult to adjust the position of the trunnion bracket and the center of the axis. Therefore repair at SMC is recommended.
D Not available at 80 and 100. Note) Mounting brackets are not mounted and are supplied loose at the time of shipment. Thread type Nil TN TF Rc NPT G Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.
www.stevenengineering.com I FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REFER TO CATALOG REFERENCE N360 1.245 AIR CHUCK SERIES MHW 180 GRIPPER SERIES MHW D I M E N S I O N S F L AT F I N G E R T Y P E MHW2-20D D I M E N S I O N S F L AT F I N G E R T Y P E MHW2-25D D I M E N S I O N S F L AT F I N G E R T Y P E MHW2-50D Courtesy of Steven Engineering, Inc. !