SMC Corporation of America
Elite Part Number Search
Search Results "RZQL32TN-100-90"

HOW Replacement Element Part No. 74 m (200 mesh) 105 m (150 mesh) 149 m (100 mesh) Element size Port size (Nominal size) 04 (1/2B) 06 (3/4B), 08 (1B) 10 (1 1/4B), 12 (1 1/2B) 16 (2B) 20 (2 1/2B), 24 (3B) 28 (3 1/2B), 32 (4B) 65 x 90 85 x 110 100 x 160 120 x 180 140 x 200 180 x 260 EM001H-074N EM101H-074N EM201H-074N EM301H-074N EM401H-074N EM501H-074N EM001H-105N EM101H-105N EM201H-105N EM301H

Table 8-1 Quality standard for fresh water (tap water) Item Product Standard value For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Sulfuric acid ion [mg/L] 50 or less 200 or less Standard item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VZS VFS VS4 VQ7 EVS Large capacity EVS7-6 (Size 1) 1200 l/min (ANR) EVS7-8 (Size 2) 3000 l/min (ANR) EVS7-10 (Size 3) 5500 l/min (ANR) VFN Cylinder driving size Flow rate 100 160 200 Rubber seal, single type Lightweight Size 1 (3 position): 0.55 kg Size

Magnetic Holding Power (lbs. force Series NCY2B Cylinder Theoretical Output 06, 410 100 o'15, 025,032, Q40 ^1100 3rooo I s00 I eoo g 7oo i m o 90 80 70 60 50 40 z 3 E .9 !

Magnetic Holding Power (lbs. force Series NCY2B Cylinder Theoretical Output 06, 410 100 o'15, 025,032, Q40 ^1100 3rooo I s00 I eoo g 7oo i m o 90 80 70 60 50 40 z 3 E .9 !

Set the regulating pressure range for the outlet pressure of the regulator in a range that is 90% or less of the inlet pressure. If set to above 90%, the outlet pressure will be easily affected by fluctuations in the flow rate and inlet pressure, and become unstable. 5.

Set the regulating pressure range for the outlet pressure of the regulator in a range that is 90% or less of the inlet pressure. If set to above 90%, the outlet pressure will be easily affected by fluctuations in the flow rate and inlet pressure, and become unstable. 5.

Set the regulating pressure range for the outlet pressure of the regulator in a range that is 90% or less of the inlet pressure. If set to above 90%, the outlet pressure will be easily affected by fluctuations in the flow rate and inlet pressure, and become unstable. 5.

Set the regulating pressure range for the outlet pressure of the regulator in a range that is 90% or less of the inlet pressure. If set to above 90%, the outlet pressure will be easily affected by fluctuations in the flow rate and inlet pressure, and become unstable. 5.

Insert the flat blade driver to the groove until it contacts the bottom of the groove and turn the driver 90 degrees. Rotating direction does not matter. Do the same for release (push and rotate for 90 degrees). Tighten the piping using the correct torque shown below.

10W 20VA 10W AC : AC1500V,1 : AC500V,1 AC :DC500V,50M 0 +50() 35 85%RH() (1s) 2000V,600V 1055Hz 0.75mm X,Y,Z 2 10G X,Y,Z 350g *1) CEU5 ,8 <> *2) 100kHz <>,, 7 - CEU5 90 A /B 90 100kHz ,A /B A +12V 10% A B +12V 10% B B C D A E F G H A : 2.5 sec E : 5 sec B : 2.5 sec F : 5 sec C : 2.5 sec G : 5 sec D : 2.5 sec H : 5 sec UPDOWN UP ,,DOWN , 100kHz ,UP.DOWN UP +12V

90 70 Gripping point L (mm) Gripping point L (mm) 12-5-7 8 Series MHR2/MDHR2 Construction MHR2 q !

18 20 24 24 B 67 97 129 165 169 245 258 A 25 40 53 70 75 90 95 M 2.3 2.3 2.3 2.3 3.2 3.2 L 40 53 70 70 90 90 K 8.4 8 10.5 10.5 13 13 J 5.4 6.5 8.5 8.5 11 11 H 22 23 26 25 35 35 G 27 40 54 54 66 66 F 30 41 50 50 70 70 E 18 16 17 14 23 23 M5 x 0.8 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 AF10 AF20 AF30 AF40 AF40-06 AF50 AF60 Optional specification Model With barb fitting B 137

Mounting with T-nuts Mounting with T-bracket 90 2561 for L5 2551 for L3 T-nut T-bracket Max. 218 to Min.158 90 54 Dedicated Controller Series LC1 Dimensions LC1-1BH LC1-1BS LC1-1BM CN5 motor power line (Molex 6P) TB1 power supply terminal CN2 general-purpose input/output (Halfpitch 20P) CN4 encoder signal line (Halfpitch 20P) CN1 control terminal (Halfpitch 26P) Indicator light 23 35.5 29

)] Flow rate [L/min (ANR)] 06, 07, 08, 09, 10 06, 07, 08, 09, 10 01, 23, 03, 04, 06, 07 01, 23, 03, 04, 06, 07 08, 09, 10, 11 08, 09, 10, 11 03, 04 200 400 06, 07 TMH 02 01, 23 300 50 03, 04 ASD 100 200 01, 23 AS 100 AS-FE 0 0 0 5 0 10 5 0 10 5 0 10 KE Number of needle rotations Number of needle rotations Number of needle rotations Note) -U10/32 has the same specification as M5.

Port size (P, A and B port) Rated voltage M5 M5 x 0.8 01 Rc 1 8 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz R1, R2: M5 4 Option 5 6 24 VDC 12 VDC Nil None With bracket (Not assembled) 7 240 VAC, 50/60 Hz 9 Other Option F Option Part No. Description Part no.

Port size (P, A and B port) Rated voltage M5 01 M5 x 0.8 1 2 3 4 5 6 7 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 1 8 R1, R2: M5 Option 24 VDC 12 VDC Nil None With bracket (Not assembled) 240 VAC, 50/60 Hz For other rated voltages, please consult with SMC. F Option Part No. Description Part no.

2 26 or less 20 or less VQC1500 0.70 Metal seal 0.72 0.15 0.16 0.25 0.18 Pressure center 33 or less 25 or less VQC1501 0.85 Rubber seal 0.65 0.20 0.21 0.42 0.18 Dual 3 port valve A B C 1 (P)(R2) 5 (R1) 3 Rubber seal VQC1 01 0.70 0.70 0.20 0.16 0.20 0.16 25 or less 33 or less 2 position double (metal) 2.0 Single VQC2100 2.6 0.15 0.46 0.15 0.60 Metal seal 22 or less 29 or less (A) 4 (B) 2 90

Max. 100 mm (MACM10-50) 100 50 (Stroke) Table center Right/left Table centering accuracy 1 mm or less (Workpiece not loaded) Rotation Forward/backward Angled 3 types of table material can be selected.

Body size 100 200 205 300 400 Metric size Inch size M3, M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard Grease-free (Sealant: Fluoro coated) + Restrictor (Without Check Valve) -X21 02 23 04 06 08 10 12 01 03 07 09 11 13 1/8" 5/32" 1/4" 5/16" 3/8" 1/2" 2 3.2 Ex.)