No code 0 V3 L 1 H 2 4 No gauge port No pressure gauge Ports -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig -30 in.Hg to 160 psig 0 to 200 psig 0 to 400 psig -0.1 to 0.2 MPa -0.1 to 0.4 MPa -0.1 to 0.7 MPa -0.1 to 1.1 MPa 0 to 1.4 MPa 0 to 3 MPa Code Ports 2 ports 3 ports 2PW 3PW Porting Configuration e w q w q 1) Other range available.
V 2-wire PLC 12 V No 200 V or less 24V Terminal conduit Relay, PLC 100 V, 200 V DIN terminal Grommet Diagnostic indication (2-color indicator) 1 Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.
S Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R Lead wire length U 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.
200 203 Series CDQ2 With Auto Switch.
[mg/L] 70 or less 200 or less Calcium hardness [mg/L] 50 or less 150 or less Ion silica [mg/L] 30 or less 50 or less Iron [mg/L] 0.3 or less 1.0 or less Copper [mg/L] 0.1 or less 0.3 or less Sulfide ion [mg/L] Not detected Not detected Referential Ammonium ion [mg/L] 0.1 or less 1.0 or less item Residual chlorine [mg/L] 0.3 or less 0.3 or less Separation carbonic acid [mg/L] 4.0 or less
less 200 or less Calcium hardness [mg/L] 50 or less 150 or less Ionic silica [mg/L] 30 or less 50 or less Iron [mg/L] 0.3 or less 1.0 or less Copper [mg/L] 0.1 or less 0.3 or less Sulfide ion [mg/L] Should not be Should not be Referential detected any detected any item Ammonium ion [mg/L] 0.1 or less 1.0 or less Residual chlorine [mg/L] 0.3 or less 0.3 or less Free carbon dioxide [mg/L]
For 200 VAC: SY100 30 2A For other voltages of AC: SY100 30 3A To detach a connector, remove the pawl from the groove by pushing the lever downward with your thumb, and pull the connector straight out.
) 1 W (With indicator light: 1.1) DC 2 2 1.4 (With indicator light: 1.5) 100 V 110 V [115 V] 1.6 (With indicator light: 1.7) 1.7 (With indicator light: 1.8) 3 1 3 1 Apparent power (VA) AC 2.3 (With indicator light: 2.4) 200 V 2.5 (With indicator light: 2.6) 2.7 (With indicator light: 2.8) 220 V [230 V] Surge voltage suppressor Refer to page 4-2-11.
Applicable Stroke Table V: Standard Stroke [mm] Model 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1100 1200 LEFS25 V V V V V V V V V V V V V V V V LEFS32 V V V V V V V V V V V V V V V V V V V V LEFS40 V V V V V V V V V V V V V V V V V V V V * Please consult with SMC for non-standard strokes as they are produced as special orders.
VN Solenoid valve option Nil Standard Rated voltage 1 2 3 4 5 6 7 8 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-9 by Applicable Fluids Check List for special fluids outside of the standard.
thread (2 each) Sides (2 each) Bottom mount 0.06 in3 (1.07 cm3) Leak rate Across the seat leak Surface finish Connections Actuation pressure Actuation port connection Actuation port location Installation Internal volume Adjustable range of metered flow 2) 10 to 200 slpm 10 to 350 slpm 6 slpm 10 slpm 15 slpm 20 slpm 10 to 20 slpm 21 to 50 slpm 51 to 100 slpm 101 to 200 slpm 201 to 350 slpm
[mg/L] 70 or less 200 or less Calcium hardness [mg/L] 50 or less 150 or less Ion silica [mg/L] 30 or less 50 or less Iron [mg/L] 0.3 or less 1.0 or less Copper [mg/L] 0.1 or less 0.3 or less Sulfide ion [mg/L] Not detected Not detected Referential Ammonium ion [mg/L] 0.1 or less 1.0 or less item Residual chlorine [mg/L] 0.3 or less 0.3 or less Separation carbonic acid [mg/L] 4.0 or less
[mg/L] 70 or less 200 or less Calcium hardness [mg/L] 50 or less 150 or less Ion silica [mg/L] 30 or less 50 or less Iron [mg/L] 0.3 or less 1.0 or less Copper [mg/L] 0.1 or less 0.3 or less Sulfide ion [mg/L] Not detected Not detected Referential Ammonium ion [mg/L] 0.1 or less 1.0 or less item Residual chlorine [mg/L] 0.3 or less 0.3 or less Separation carbonic acid [mg/L] 4.0 or less
For Air Upstream pressure of valve P1 1.0 MPa 1.0 Downstream pressure of valve (P2) MPa Downstream pressure of valve (P2) MPa 0.8 Subsonic Critical pressure 0.9 0.6 0.7 0.8 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 VX211 VX22 VX23 VX2 4 VX2 5 VX2 60-02 VX2 602 50 100 150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500
(120) 3 position 0.35 0.48 [0.57] [0.41] [1.3] center 3.3 0.78 0.43 Pressure 0.45 0.56 2.1 [0.85] [0.25] [0.54] center 170 (90) Single 2.3 0.61 0.35 0.74 2.9 0.41 2 position 190 (110) Double Closed 1.9 0.50 0.44 0.60 2.2 0.46 center 1/4 Note 1) M5 x 0.8 SYJA740-02 Exhaust 0.27 0.87 3.7 3 position 1.3 200 (120) 0.35 0.45 center [0.56] [1.4] [0.43] 3.6 Pressure 0.84 0.23 0.47 0.58 2.1 [0.83
A 3 4 , 1 2 150 165 42.7 76.3 45 65 40 60 35 40 80 80 1 1 3 4 ALBA90-10 ALBA90-20 14-13-19
S L, Z S L, Z 1 1 1 1 4 1 2 PB AC 2 Ordering example (Example) Series VXR22, Rc 1 1/4, 200 VAC, Conduit terminal (Part no.)
Off-DeJ av 200 50 mS Off-Delay time 20 -Auto SWitch Series eLA Reed Type Internal Circuit 0-853, 0-A53 0-A64, 0-864 D-A59W, D-859W Choke COIl a,own (t-) (red) Z8M! dod, ZOl'ler 0I0de '--c:::=~J_~ Blue t-)(b!
Inch size 1/4" 1/8" 5/32" Flow rate (l/min(ANR)) 170 100 120 150 IN OUT Effective area (mm2) 2.6 1.5 1.8 2.3 IN P1 Note) Flow rate is the value measured under a pressure of 0.5 MPa and a temperature of 20C.
CM2X With auto switch CDM2X C73 Number of auto switches L 40 150 2 pcs. 1 pc.