.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Impact/Vibration resistance (m/s2) Note 2) 150/30 Dustproof Enclosure Note 1) Based on dynamic performance test JIS B8374-1981 (Standard type: at coil temperature of 20C, with rated voltage, without surge voltage suppressor) Note 2) Impact resistance:
(Coil temperature 20C, at rated voltage, without surge voltage suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) When equipped with DC solenoid/surge voltage suppressor, a delay of about 20 to 30 m/sec. occurs in the OFF response time.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) Note 2) This solenoid valve requires lubrication. Use turbine oil Class 1 (ISO VG32).
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage) (B) 2 (A) 4 Weight SOL.b SOL.a 3 (EB) 5 (EA) Weight (g) Series Type of actuation 1 (P) 66 Single solenoid 4 position dual 3 port valve: N.O.
Impact/Vibration resistance (m/s2) 150/50 Note) Manifold Possible Use dry air (Dew point: 20C or less). If using a lubricant, be sure to use a lubricant for low temperatures.
Specifications Applicable tubing material Nylon Soft nylon 4/2.5 3.18/2, 4/2.5 Polyurethane M3 Applicable tubing 4/2.5 6/4 3.18/2.18 4/2.5 6/4 3.18/2 4/2.5, 6/4 1 8 M5-R Line up various styles For air connection in confined areas. 1.5 MPa 1.0 MPa 0.8 MPa Max. operating pressure (at 20C) 1 8 M3, M5, R Connection size JIS B 0209 Class 2 (Metric coarse thread), JIS B 0203 (Taper pipe thread
Please contact us for the latest version.sales@ocaire.com, 20MM MHZ2, ACTUATOR, MHZ2 GRIPPER, PARALLEL, HT, 20MM MHZ2, 0.54066 lb, ActionModelBore size (mm)Gripping force Note 1)Opening/ Closing stroke (Both sides) (mm)Note 2) Mass (g) Gripping force per finger Effective value (N) ExternalInternalSingle actingNormally closedMHZ2-20C(N)20?5710240
IDG60M, IDG100M are fitted with AMH micro mist separator with pre-filter. 1.77 3.53 5.29 Flow Flow Flow 10 25 50 100 200 300 500 600 750 1000 110 170 240 300 100 150 75 50 Single Type 76F (60C) Dew point Single Type 40F (40C) Dew point Single Type 4F (20C) Dew point 3.53 5.29 8.02 11.3 14.12 2.72 5.44 8.29 0.44 1.09 2.19 4.41 8.83 13.24 22.07 25.6 31.78 42.02 Model Inlet Model Inlet Model
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
Metric sizes 6 8 10 12 Flow rate l/min (ANR) Controlled 100 180 230 260 390 460 660 790 920 1580 1710 (free) flow Effective area mm 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Note) Flow rate values are at a pressure of 0.5MPa, and temperature of 20C.
capacity (cm3) 55 135 7 135 25 135 135 Recommended lubricant Class 1 turbine oil (ISO VG32) 5 to 60C (with no freezing) Ambient and fluid temperature Bowl material Polycarbonate Bowl guard Standard Option Weight (kg) 0.47 0.24 1.13 0.07 0.52 1.06 0.20 Notes 1) The flow rate is 5 drips/min under the following conditions: Inlet pressure of 0.5MPa; Class 1 turbine oil (ISO VG32); Temperature at 20C