M5 thread With 3.2 One-touch fittings With 4 One-touch fittings With 6 One-touch fittings M5 thread 2(B) (A)4 Side ported 5 (R1)5 1 (P) 3(R2) Note) For double solenoid specification, the function symbol below is D.
2 2-8 counterbore with depth 4.3 2 2-5.5 through 2 2-9.5 counterbore with depth 5.3 2 2-6.5 through 2 2-11 counterbore with depth 6.3 2 2-6.5 through 2 2-11 counterbore with depth 6.3 2-M4 0.7 with depth 6 15 2-M5 0.8 54 19 70 52 17 8.5 42 25 5 10 2.5 20 8 9.5 38 57.5 9 2-M4 0.7 with depth 6 20 2-M5 0.8 62 24 84 60 22 11 50 29 6 12 4.5 25 10 12 45 67.5 9 2-M5 0.8 with depth 7.5
Effective area (mm2) Weight (g) A L M Model
Millimeter Inch With One-touch fittings 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 01 03 05 07 09 11 4 6 8 10 12 04 06 08 10 12 Thread _ Meter thread (M5) Unified thread (10-32 UNF) R(PT) N NPT Port size M5 X 0.8 10-32UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 AS ASN AQ ASV Needle Valve/Flow Characteristics AK ASD230F ASD330F ASD430F ASS 100 200 400 1.5 6 3 07, 08, 09, 10, 11 Effective area (mm2) Flow
Port size (A port) Rated voltage Option M5 M5 x 0.8 01 Rc 1 8 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz Nil None With bracket (Not assembled) P, R port: M5 4 5 6 24 VDC 12 VDC F Thread type 7 240 VAC, 50/60 Hz 9 Other Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800
Effective area (mm) Weight g A
H MM NN MQ10-M MQ16-M MQ20-M MQ25-M MQ28-M 10 M5 x 0.8 M3 x 0.5 10.5 16 M6 x 1.0 M4 x 0.7 11.5 20 M8 x 1.25 M5 x 0.8 13.5 25 M10 x 1.25 M6 x 1.0 16.5 30, 40 M14 x 1.5 M8 x 1.25 22.5 Clevis pin d Dd9 m m l t L t Applicable bore size (mm) Applicable snap ring Part no.
2 2-8 counterbore with depth 4.3 2 2-5.5 through 2 2-9.5 counterbore with depth 5.3 2 2-6.5 through 2 2-11 counterbore with depth 6.3 2 2-6.5 through 2 2-11 counterbore with depth 6.3 2-M4 0.7 with depth 6 15 2-M5 0.8 54 19 70 52 17 8.5 42 25 5 10 2.5 20 8 9.5 38 57.5 9 2-M4 0.7 with depth 6 20 2-M5 0.8 62 24 84 60 22 11 50 29 6 12 4.5 25 10 12 45 67.5 9 2-M5 0.8 with depth 7.5
With brake: 150 Without brake: 115 Housing 36.5 32 Thread size M4 x 0.7 6 4 70 M5 x 0.8 6 4 70 Effective thread length (mm) Quantity P.C.D. B 89 A A B Section BB Coupling P.C.D.
AC200230V AC100120V 40 M5 3.24[Nm] M5 3.24[Nm] 6 AC100120V AC200230V AC100120V AC200230V L1 L1 PE PE L2 2-M5 2-M5 L2 L3 CNP1 CNP1 N N P1 P1 M4 1.2[Nm] P2 P2 M4 1.2[Nm] P P C C CNP2 D CNP2 D L11 L11 L21 L21 U U CNP3 V CNP3 V W W 9 2 9 (2) LECSS-S8 [mm] 5 40 6 6 6 (80) (170) 6 6 () CN4 CN2L CN2 CN1B CN1A CN3 CN5 CNP1 L1 L2 L3 N P1 P2 P C D L11 L21 U V W L1 L2 () L3 N P1 CNP2 P2
b LECSS2-T9 c 12 12 1560.5 6 420.3 M5 d a 4.9 /LECS / 1./ YES [ ]NO [ ] 2.
The VM series offers a wide variety of actuator styles and flow capacity up to 1.0 Cv.Actuator replacements for VM100, VM200, VM400 and VM800, Roller levers, plungers, toggle levers, rod levers, push buttons and twist selectors, VALVE, MECHANICAL, VALVE, VM (VFM/VZM) MECHANICAL VALVE, BA, VM BODY PT(M5, NON-US STD), .30712 lb
x 0.8 x 16 M5 x 0.8 x 20 M5 x 0.8 x 25 ( ): Denotes the values of D-A44C Dimensions (mm) D-A3C D-A44C 2 x M5 x 0.8 x 12 Hexagon socket head cap bolt Tightening gland 2 x M5 x 0.8 x 12 Hexagon socket head cap bolt Tightening gland G 1/2 G 1/2 4 x Z 4 x Z (Applicable cable O.D. 6.8 to 9.6) (Applicable cable O.D. 6.8 to 11.5) Hexagon socket head cap bolt Hexagon socket head cap bolt Indicator
M5, 1/8, 3.2 to 6 1, 1.6, 2.3, 3.2 N.C.
x 0.8 1/8 1/4 Model MY2H16G MY2H25G MY2H40G MM M4 x 0.7 M5 x 0.8 M6 x 1 L 80 110.8 180 LD 3.4 5.5 9 LB 50.4 71.7 80.3 LA 70 100 158 J M3 x 0.5 M5 x 0.8 M6 x 1 H 28 37 58 GB 17 19.5 31.5 G 8.5 10.7 15.5 N 20 25 40 C 3.3 5.4 32.5 M 7 9 13 B 6.5 9.5 14 LW 83 123 161 A 80 105 165 (LL) 40 49.6 75 LE 4 5 6 NC 14 21.3 32.4 NT 3.5 5.3 6.5 NE 27 35.5 56.5 NH 2 3 4 NX 5.8 8.5 10.5 NW 48.2 71.8 82.1
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 97 8.5 115 118 Purge air for dehumidification 5 M5 x 0.8 Drain Drain (Maintenance space 100 mm or more) 5.5 M5 x 0.8 With fittings for purge air discharge (Option: P) Purge air discharge tubing port for dew point indicator Applicable tubing O.D.: 8 Port
Bore size Standard stroke (mm) MM YY L X K W J V H GA GB TA TB U G T F S DA R C Z NN Q B ML P PW YL (mm) 12 16 20 25 18 50 13 5 16 40 58 5 7.5 5 36 29 56 8 22 6 48 29 12 14 39 7 10, 20, 30, 40, 50, 75, 100 M4 x 0.7 10 M4 x 0.7 M5 x 0.8 7 M4 x 0.7 11 22 54 15 7 18 42 64 2.5 8 5.5 38 33 62 8 25 8 52 33 13 16 43 8 10, 20, 30, 40, 50, 75, 100 M5 x 0.8 13 M5 x 0.8 M5 x 0.8 5 M5 x 0.8 11 20, 30
-ASD330F-01-08 10-ASD230F-M5-06 2.
x 0.8 1/8 1/4 MM M4 x 0.7 M5 x 0.8 M6 x 1 L 80 110.8 180 LD 3.4 5.5 9 LB 50.4 71.7 80.3 LA 70 100 158 J M3 x 0.5 M5 x 0.8 M6 x 1 H 28 37 58 GB 17 19.5 31.5 G 8.5 10.7 15.5 N 20 25 40 C 3.3 5.4 32.5 M 7 9 13 B 6.5 9.5 14 LW 83 123 161 A 80 105 165 (LL) 40 49.6 75 LE 4 5 6 NC 14 21.3 32.4 NT 3.5 5.3 6.5 NE 27 35.5 56.5 NH 2 3 4 NX 5.8 8.5 10.5 NW 48.2 71.8 82.1 NV 3.4 5.5 6.6 Model MY2H16G
Workpiece fixed Model Screw size Max. tightening torque [Nm] L (Max. screw-in depth) [mm] EQFS16 M4 x 0.7 1.5 6 EQFS25 M5 x 0.8 3.0 8 EQFS32 M6 x 1 5.2 9 EQFS40 M8 x 1.25 12.5 13 L To prevent the workpiece retaining screws from touching the body, use screws that are 0.5 mm or shorter than the maximum screw-in depth.