Refer to page 562 for details. () (+) 8A Station 8 SOL.B () (+) 8B SOL.A () (+) 9A Station 9 SOL.B () (+) 9B SOL.A () (+) 10A Station 10 SOL.B () (+) 10B 6 (+) () COM. Note) Positive COM spec. Negative COM spec. Step 3. Mounting the terminal block cover Securely tighten the screws after confirming that the gasket is installed correctly.
(C) IDF 1D 30 35 40 50 25 IDF 2D to 240D 30 35 40 45 50 Outlet air press. dew point (C) Ambient temp.
A,Caution lf surge voltage is generated on the power supply line, according to the operating conditions, circuit should be equipped with zener diode "2D", 30 to 35V, or condenser, 0.1pF, etc. in order to eliminate the surge voltage. Do not start the operation before confirming disappearance of surge voltage, 3.
Test range Thermometer Equipment Pressure Pressure for test tap tap Restrictor Flow Restrictor on the 2d 6d on the meter downstream side upstream side r 20d r 10d Fig. (3) Test circuit based on IEC60534-2-3, JIS B 2005 32 Series VXN Flow-rate Characteristics Note) Use this graph as a guide. In the case of obtaining an accurate flow rate, refer to pages 28 through to 32.
. * The surface finish of the outer surface of the container is equivalent to No. 2D**1.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Compatible Fluid: Coolant, Operating Environment: Standard, Type: Air Operating Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/4, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~60, Driving Type: Pilot Type, Orifice Diameter(Ø): 7, Voltage: -, Sealing materials:
Compatible Fluid: Coolant, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/4, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Orifice Diameter(Ø): 7, Voltage: 100 V AC, Sealing materials
Compatible Fluid: Steam, Operating Environment: Standard, Type: Air Operating Type, Number of Solenoids: -, Switching Type: Normally Closed, Application: -, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/4, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~60, Driving Type: Pilot Type, Operating Pressure Difference Range(MPa): -, Orifice Diameter(Ø): 7, IP Rating: -, Insulation
Compatible Fluid: Steam, Operating Environment: Standard, Type: Air Operating Type, Number of Solenoids: -, Switching Type: Normally Closed, Application: -, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/4, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~60, Driving Type: Pilot Type, Operating Pressure Difference Range(MPa): -, Orifice Diameter(Ø): 7, IP Rating: -, Insulation
Compatible Fluid: Steam, Operating Environment: Standard, Type: Air Operating Type, Number of Solenoids: -, Switching Type: Normally Closed, Application: -, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/4, Tube Flange Nominal: -, Operating Temperature Range(°C): -5~60, Driving Type: Pilot Type, Operating Pressure Difference Range(MPa): -, Orifice Diameter(Ø): 7, IP Rating: -, Insulation
Compatible Fluid: Air / Oil / Gas, Operating Environment: Standard, Type: Air Operating Type, Number of Solenoids: -, Switching Type: Normally Closed, Body Material: Aluminum, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/4, Operating Temperature Range(°C): -5~60, Driving Type: Pilot Type, Orifice Diameter(Ø): 10, Voltage: -, Sealing materials: NBR
Compatible Fluid: Oil / Gas, Operating Environment: Standard, Type: Air Operating Type, Number of Solenoids: -, Switching Type: Normally Closed, Body Material: Aluminum, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/4, Operating Temperature Range(°C): -5~60, Driving Type: Pilot Type, Orifice Diameter(Ø): 10, Voltage: -, Sealing materials: FKM, Bracket
Compatible Fluid: Air / Oil / Gas, Operating Environment: Standard, Type: Air Operating Type, Number of Solenoids: -, Switching Type: Normally Open, Body Material: Aluminum, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/4, Operating Temperature Range(°C): -5~60, Driving Type: Pilot Type, Orifice Diameter(Ø): 10, Voltage: -, Sealing materials: NBR,
Compatible Fluid: Air / Oil / Gas, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Body Material: Aluminum, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/4, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Orifice Diameter(Ø): 10, Voltage: 110 V AC
Compatible Fluid: Air / Oil / Gas, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Body Material: Aluminum, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/4, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Orifice Diameter(Ø): 10, Voltage: 24 V DC,
Compatible Fluid: Air / Oil / Gas, Operating Environment: Standard, Type: Electromagnetic Type, Number of Solenoids: Single Solenoid, Switching Type: Normally Closed, Body Material: Aluminum, Application: Individual Item, Connection Type: [Rc (R)] Rc, Plumbing Thread Nominal: 1/4, Operating Temperature Range(°C): -5~50, Driving Type: Pilot Type, Orifice Diameter(Ø): 10, Voltage: 24 V DC,
Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: NBR Seal, Body Material: Standard, Pilot System Option: Standard, Thread: Rc(PT), Port Size: 1/4, Voltage: 100VAC 50/60HZ, Lead Wire: Conduit Terminal, Manual Override: -, Bracket: -
Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: NBR Seal, Body Material: Standard, Pilot System Option: Standard, Thread: Rc(PT), Port Size: 1/4, Voltage: 110VAC 50/60HZ, Lead Wire: Conduit Terminal, Manual Override: -, Bracket: -
Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: B (FKM Seal), Body Material: Standard (Bronze Body), Pilot System Option: Standard, Thread: Rc(PT), Port Size: 8A (1/4), Bracket: B (Bracket)