Valve; w/Stop Valve), Return Port Size: 03 (3/8), Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal;
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal;
Valve; Stop Valve: None), Return Port Size: 03 (3/8), Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
BM Bellows type with groove UM Flat type with groove KJH C2 06 Pad diameter Applicable tubing O.D. 63 63 80 80 04 4 06 6 03 5/32" 07 1/4" When changing the pad diameter, replace also the plate together. !
Power supply is AC200V single phase (Note 4) Controller Forced Alarm forced stop stop ON OFF RA1 RA2 MC MC SK Driver Servo amplifier Servo motor NFB MC CNP1 L1 1-phase 200 to 230VAC CNP3 (Note 6) U 2 L2 U Motor [1] V 3 L3 V M N W 4 W 1 P1 (Note 1) P2 PE CNP2 P (Note 2) C [3] [2] D (Note 3) Encoder CN2 Encoder cable L11 L21 CN3 CN3 24VDC Forced stop EM1 DOCOM (Note 5) DOCOM DICOM (Note 5)
. 5 1 5 . 4 6 5 . 4 2 2 . 5 1 7 . 3 1 6 4 5 . 8 1 6 . 5 2 7 . 7 1 2 2 0 1 0 1 9 9 0 1 U 2 Q K 5 . 8 1 5 . 1 7 5 . 7 2 5 . 8 1 1 . 6 1 5 . 0 5 1 2 0 4 4 . 8 2 6 2 2 1 2 1 9 9 2 1 U 2 Q K 9 . 0 2 5 . 5 7 0 3 9 . 0 2 1 . 8 1 5 . 3 5 2 2 4 . 7 5 4 . 5 4 2 3 6 1 6 1 9 9 6 1 U 2 Q K 5 . 6 2 0 9 5 . 6 3 5 . 6 2 3 2 5 6 5 2 3 1 1 ) 3 1 1 ( 8 7 Branch Y: KQ2U Inch Applicable tube O.D.
06 10 1/4 3/8 1/2 3/4 1 Applicable model AMR3l00-02 to 03 AMR4l00-02 to 04 AMR5l00-04 to 06 AMR6l00-10 R 3 4 5 6 Body size 3 4 5 6 Adapter ass'y port size (2 pcs.)
F.S. or less (0 to 50C) Pulse output, N channel, open drain, output for display unit PF2D300/301 Pulse output (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V) Output Voltage output Note 5) 1 to 5 V within the flow rate range Analog Linearity: 2% F.S. or less, Allowable load resistance: 100 k or more specifications output Current output Note 6) 4 to 20 mA within
1 5 20 1 5 1 0 25 20 1 5 30 25 25 2.
B 69 78.5 CL CL B 88 98.5 19.5 22.5 78 88.5 A A + Stroke CL + Stroke RR CW CU 5 79 88.5 29.5 32.5 5 to 50 5 to 50 20 25 L G B + Stroke +0.4 +0.2 -0.1 -0.3 CZ CX Bore size (mm) CD CX G S CW CZ L L1 RR CU 12 14 8 10 27 31 39.2 43.2 18 20 8 10 16 20 4.5 5 18.5 22.5 9 10 20 25 Rod end nut L1 8 Series CLQ Dimensions/32 Double end tapped: CLQA32 16 3.2 2 x 4-M5 x 0.8 16 3.2 Standard type (through
hole 5 5 5 5 120 130 5 5 Summary of input/output signals (connector CN-1/F) Pin No. 1 2 3 4 5 7 8 9 10 Pin No. 11 12 13 14 15 16 17 19 20 Signal name Digital output power supply Failure Positioning completion Z phase pulse Symbol V+ ALM PF OP SG NP NG PP PG Signal name Shield Driver model MR-C10A MR-C10A1 Symbol SD SG CR LSN LSP V5 SON OPC V24 Interface power supply common Clear Reverse stroke
ALT-5-IS ALT-9 ALT-9-IS 449 482 1.17-14 Oil Distributor VA, VB/Nylon Tubing Related Products Oil Distributor Series VA, VB How to Order V A 4 6 Applicable tube O.D. 6 6 Oil Distributor Number of distribution ports (VA) (VB) VB6-6 Distribution 4 ports 6 ports 8 ports 4 ports 6 ports 10 ports 16 ports 4 6 8 4 6 10 16 Both sides exhaust One side exhaust A B VA4-6 Dimensions VAl-6 VBl-6 A B C
Pressure Control Equipment Specifications 0 to 1 MPa Rated pressure range Output Specifications 0.1 to 1 MPa Set pressure range NPN open collector output 1.5 MPa Withstand pressure Max. 30 V, 80 mA Residual voltage 1 V or less 0.01 MPa Set pressure resolution 12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection) Power supply voltage Brown DC (+) 55 mA or less (at
Pressure Control Equipment Specifications 0 to 1 MPa Rated pressure range Output Specifications 0.1 to 1 MPa Set pressure range NPN open collector output 1.5 MPa Withstand pressure Max. 30 V, 80 mA Residual voltage 1 V or less 0.01 MPa Set pressure resolution 12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection) Power supply voltage Brown DC (+) 55 mA or less (at