JIS Symbol How to Order 1 F 06 3 200 AS Flow Direction Symbols on Body JIS Symbol Body size Panel mount type Symbol M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 100 200 205 300 400 Applicable tubing O.D.
Work piece Vacuum regulator Body size 1 2 3 IRV1000 type IRV2000 type IRV3000 type Leak tester Pressure transducer Solenoid valve Solenoid valve Work piece Vacuum pump IRV Filter Thread type Nil N F Rc NPT G Optional Inspection equipment Port size Solenoid valve Application IRV Work piece Tank Vacuum pump Filter Symbol Bore IRV1000 IRV2000 IRV3000 01 02 03 04 1/8 1/4 3/8 1/2 Flow meter Accessories
-14No.EX-OMP0004CN-I D 3 -15No.EX-OMP0004CN-I LED LED LED L ERR L RUN PWR ON OFF PWR(V) ON OFF -16No.EX-OMP0004CN-I DIP (0.2 Nm) -17No.EX-OMP0004CN-I 5 L ERRLED 00 65 L ERRLED HOLD/CLEAR HOLD/CLEAR No.1 HOLD ON CLEAR OFF No.2 ON 110 OFF -18No.EX-OMP0004CN-I EX260-SMJI/O (1 32 /32 ) SI [01] QJ61BT11N EX260-SMJ1/2 I/O (1 ) (RY) (RX) (RX) (RY) E0H RX0FRX00
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in10R 1/8AS2201FG-01-10AS2211FG-01-10----
/OTHER), .03675 lb, Bore size (mm)Model Elbow typeStraight typeIn-line type20AS2201F-01-06-X214AS2301F-01-06-X214AS2001F-06-X214
Size: 01 (Size 01), Passage Symbol: FHG (3 Position Closed Center), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: None, Sealing Type: R (Rubber Seal), Port Size: A02 (Side Ported, 1/4), Thread: F (G)
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12 FLOW CONTROL W/FITTING. FLOW CONTROL. AIRLINE EQUIPMENT. AS***F 10/32 STANDARD (NPT). .00000 lb. BD.
>① Body ported VFS series
Single/Base mounted VFS2000 series:② Base mounted VFS2000 series
Single/Base mounted VFS3000/5000/6000 series: ③ Base mounted VFS3000 to 6000 series
Manifold/01
For valves which had an “E” prefix, the thread type now needs to be indicated in the part number (e.g., symbol “F” for G thread).
Valve part number example: EVT307-5DO-01-Q→VT307-5DO-01F-Q
Example of valve series with an “N” prefix: NVT3, NVO3, NVK, NVP, NVF, NVS, NVN, NVY, etc.
Size: 01 (Size 01), Passage Symbol: FG (2 Position Double), Number of Solenoids: S (Single), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: R (Rubber Seal), Port Size: A02 (Side Ported, 1/4), Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FG (2 Position Double), Number of Solenoids: S (Single), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: Metal Seal, Port Size: A02 (Side Ported, 1/4), Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FIG (3 Position Pressure Center), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: Metal Seal, Port Size: A01 (Side Ported, 1/8), Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FG (2 Position Double), Number of Solenoids: S (Single), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: Metal Seal, Port Size: A01 (Side Ported, 1/8), Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FJG (3 Position Exhaust Center), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: Metal Seal, Port Size: A02 (Side Ported, 1/4), Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FJG (3 Position Exhaust Center), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: R (Rubber Seal), Port Size: A02 (Side Ported, 1/4), Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FG (2 Position Double), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: Metal Seal, Port Size: A02 (Side Ported, 1/4), Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FJG (3 Position Exhaust Center), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: R (Rubber Seal), Port Size: w/o Sub-plate, Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FHG (3 Position Closed Center), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: Metal Seal, Port Size: A01 (Side Ported, 1/8), Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FHG (3 Position Closed Center), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: Metal Seal, Port Size: A02 (Side Ported, 1/4), Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FG (2 Position Double), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: R (Rubber Seal), Port Size: A02 (Side Ported, 1/4), Thread: F (G)