SMC Corporation of America
Elite Part Number Search
Search Results "VV3K3-20-10-F-00N"

with double knuckle joint. +0.058 0 +0.058 0 +0.070 0 +0.084 0 +0.084 0 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30 14 19 24 26 26 20 22 28 40 40 30 40 50 60 60 M10 x 1.25 16 19 24 34 34 M10 x 1.25 10 11 14 20 20 16 19 24 34 34 40 50 64 80 80 10 10 14 22 22 14 14 20 30 30 28 28 40 60 60 10 10 14 22 22 14 14 20 30 30 12 M14 x 1.5 M14 x 1.5 12.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M18 x 1.5

0 10 20 30 40 50 60 0 10 20 30 40 50 F F Gripping point L mm Gripping point L mm MRHQ16D MRHQ16D Pressure 0.7MPa External gripping 60 50 0.6MPa 50 Pressure 0.7MPa Gripping force N Gripping force N 0.5MPa 40 0.4MPa 0.5MPa 0.6MPa 40 0.4MPa 30 30 0.3MPa 0.3MPa 20 20 0.2MPa 0.2MPa 10 10 L L 0 10 20 30 40 50 60 0 10 20 30 40 50 60 Gripping point L mm Gripping point L mm MRHQ20D MRHQ20D Internal

0 -0.074 0 -0.087 40 45 66 R0.5 23 10 60 44 18 25 14 17.5 M8 x 1.25 18 10 20 M14 x 1.5 30 1/4 37 114 11 17 15 50 50 73 R0.5 M10 x 1.5 25 9 73 53 20 28 17 17 20 10 22 M16 x 1.5 30 3/8 43 116 11 19 15 63 55 80 R0.5 M10 x 1.5 28 8 80 60 22.4 30 17 17 22 10 25 M18 x 1.5 30 3/8 47 120 11 21 15 80 65 90 R2.5 M12 x 1.75 32 8 100 75 28 32 22 20 26 13 29 M22 x 1.5 35 1/2 57 132 11 26 25 100 80 100

CZ D F GB GD B GA GC 32 1/8 12 30 8.5 22 17 6 46 97 32.5 10 14 28 12 13 13 13 to 500 19.5 54 10 83 45.5 40 1/8 12 35 10 30 22 8 52 104 38 10 14 28 16 13 14 16.5 to 500 27 63 14 91 52.5 50 1/4 15 40 12.5 35 27 11 65 120.5 46.5 14 20 40 20 14 15.5 19 to 600 32 75 18 104.5 58.5 63 1/4 12 45 17.5 35 27 11 75 134.5 56.5 14 20 40 20 14 16.5 23 to 600 32 90 18 119.5 68 80 1/4 18 45 22 40 32 13 95

, IDF6E-10 IDF8E-10, IDF11E-10 Type 100 V 10 A IDU3E-10, IDU4E-10 IDU6E-10 30 mA IDF4E-20, IDF6E-20 IDF8E-20, IDF11E-20 Type 200 V 5 A IDU3E-20, IDU4E-20 IDU6E-20 S Option symbol IDF1E-10 to 11E-10, IDU3E-10 to IDU6E-10 With power cord connection The option allows the connection of a power cord to a terminal block.

Setting of [F 0] Unit selection function completed -22No.PF-OMJ0018-F Flow specification when [ Ft] is selected by unit selection function Model PFM710 PFM725 PFM750 PFM711 Dry air, N2, Ar 0.8 to 35.3 1.8 to 88.3 4 to 177 8 to 353 CFM x 10-2 CFM x 10-2 CFM x 10-2 CFM x 10-2 Rated flow range CO2 0.8 to 17.6 1.8 to 44.1 4 to 88 8 to 176 CFM x 10-2 CFM x 10-2 CFM x 10-2 CFM x 10-2 Dry air, N2Ar

9 Appendix 9.5.4 Recirculating fluid Pressure Loss Fluid: Water HED003 35 30 Pressure loss kPa 25 HED003-HW13 20 15 10 HED003-HW19 5 0 0 2 4 6 8 10 12 14 16 18 20 Flow rate L/min Fig.9-13 Recirculating fluid Pressure loss (HED003) HED005, HED007 35 30 Pressure loss kPa 25 HED005-HW13 HED007-HW13 20 15 10 HED005-HW19 HED007-HW19 5 0 0 2 4 6 8 10 12 14 16 18 20 Flow rate L/min Fig.9-14 Recirculating

MPa 10 0.01 0.1 0.1 1 20 MPa 20 0.01 0.1 0.1 2 25 MPa 25 0.02 0.2 0.2 2 Additional range 1 USEr It varies depending on the minimum unit setting of the additional range.

(Including band and screw) Operating Range Bore size (mm) Bore size (mm) Auto switch model Auto switch model 20 25 32 40 50 20 25 32 40 50 D-C7/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 D-B7/B80 BMA2 -025 BMA2 -032 BMA2 -040 BMA2 -050 BMA2 -020 10 8 10 9 10 D-B73C/B80C D-C7/C80 BA -32 BA -04 BA -05 BA -01 BA -02 10 8 10 9 10 D-C73C/C80C D-B5/B64 BM1 -01 BM1 -02 BM1 -32 BM1 -04 BM1 -05 10 8

/20. 9-1 9.1.2 HRR010-W-10/20. 9-3 9.1.3 Refrigerant with GWP reference . 9-5 9.1.4 Communication specification . 9-5 9.2 Outline dimensions . 9-6 9.2.1 HRR010-A-10/20. 9-6 9.2.2 HRR010-W-10/20. 9-7 9.3 Flow Chart . 9-8 9.3.1 HRR010-A-10/20. 9-8 9.3.2 HRR010-W-10/20. 9-8 HRR Series HRX-OM-X084 Contents 9.4 Cooling capacity . 9-9 9.4.1 HRR010-A -10. 9-9 9.4.2 HRR010-W-10. 9-9 9.4.3 HRR010-

N N M TT S + Stroke H BY TX TZ ZZ + Stroke BW With rod boot 180, 200, 250 Z1+ l + 1/2 stroke BV BZ BG BE e 4-MA Effective thread depth MB (To attach eyebolt) f l 15 h + l ZZ1 + l + Stroke Bore size (mm) Stroke range (mm) J M AL B C E F FA GA K KA N A BA BB BC BD BG BE BZ BV BW BP D EA GB GC H MM P BY MB MA 125 140 160 180 200 250 14 14 14 17 17 20 15 15 17 20 20 25 31 31 36 41 46 56 19 19

pulses) 10[V] 10[V] 10[pulse] 10[pulse] 0 0 10[pulse] 10[pulse] -10[V] -10[V] CW direction CW direction CCW direction CCW direction A Feedback position (Note 1,2) ( 10V/1 Mpulses) B Feedback position (Note 1,2) ( 10V/10 Mpulses) 10[V] 10[V] 1M[pulse] 10M[pulse] 0 0 1M[pulse] 10M[pulse] -10[V] -10[V] CW direction CW direction CCW direction C Feedback position (Note 1,2) ( 10V/100 Mpulses)

Mode 27 Simple Setting Mode 29 Function Selection Mode 31 Function selection mode 31 Default setting 31 F 0 Differential pressure check mode, pressure range, display unit 33 F 1 Setting of OUT1 39 F 2 Setting of OUT2 42 F 3 Digital filter setting 44 F 4 Auto-preset function 45 F 6 Fine adjustment of display value 47 F10 Sub display setting 48 F11 Display resolution setting 54 F14 Zero cut-off

DKeyway dimensions l b D (g6) D (g6) DD (h9) Port size Rc Model Model A B C F H J K S U W BA BB G M N UU L CA CB 20M8 x 1.25 Depth 8 144 (177) CRA1BW50 CRA1BS50 1/8 62 48 46 15 2.5 36 5 98 17 17 8.5 8.5 13 15 11 20 15 118 14 25 5 0 0.030 25 M10 x 1.5 Depth 12 163 (201.5) CRA1BW63 CRA1BS63 1/8 76 60 57 17 2.5 41 5 117 19.5 20 10 10 14 17 13 22 17 139 16 30 6 0 0.030 30 M12 x 1.75 Depth 13

DKeyway dimensions l b D (g6) D (g6) DD (h9) Port size Rc Model Model A B C F H J K S U W BA BB G M N UU L CA CB 20M8 x 1.25 Depth 8 144 (177) CRA1BW50 CRA1BS50 1/8 62 48 46 15 2.5 36 5 98 17 17 8.5 8.5 13 15 11 20 15 118 14 25 5 0 0.030 25 M10 x 1.5 Depth 12 163 (201.5) CRA1BW63 CRA1BS63 1/8 76 60 57 17 2.5 41 5 117 19.5 20 10 10 14 17 13 22 17 139 16 30 6 0 0.030 30 M12 x 1.75 Depth 13

10 0 90 Vacuum pressure reached 80 kPa Vacuum pressure in tank [kPa] 80 Vacuum pressure [kPa] 66 kPa 70 60 53 kPa 50 40 kPa 40 26 kPa 30 20 13 kPa 10 0 Suction flow rate [L/min (ANR)] 10 0 20 30 40 50 60 70 80 90 100 1 10 Time to reach vacuum [s] 1 0 2 3 4 5 6 7 8 9 10 11 12 Vacuum Break Flow Rate Characteristics*1 (Representative value) *1 Silencer exhaust specification The graph shows

Number of fingers and therefore, mg F 2 x With "a" as the safety margin, F is determined as follows: mg F = x a 2 x When = 0.2 When = 0.1 mg F = x 4 2 x 0.2 mg F = x 4 2 x 0.1 = 10 x mg = 20 x mg 10 x work piece weight 20 x work piece weight (Note) Even in cases where the coefficient of friction is greater than = 0.2, for safety reasons, P/A recommends selecting a gripping force which

12 16 5, 10, 15, 20 25, 30 2.2-10 20 25 5, 10, 15, 20 25, 30, 35, 40 45, 50 Series CQS 12, 16 20, 25 12 16 20 25 5, 10 2.2-16 Solid state switch D-F9N, F9NV D-F9P, F9PV D-F9B, F9BV D-F9NW, F9NWV D-F9PW, F9PWV D-F9BW, F9BWV Series CQSK 12 16 5, 10, 15, 20 25, 30 20 25 5, 10, 15, 20 25, 30, 35, 40 45, 50 2.2-24 Series CQSlS 12 16 5, 10, 15, 20 25, 30 20 25 5, 10, 15, 20 25, 30, 35, 40 45,

Bellows, O-ring Seal P.20 to P.25 105 to 10-6 10-10 10-11 2 Eliminates pump over loads XLDV (With solenoid valve) Standard For portable equipment not requiring air Standard XLH Bellows Seal Standard 105 to 10-6 10-10 10-11 0.1 P.26, P.27 Manual Particulate free completely cleaned Single acting (N.C.)