Basic weight 0.74 P Additional weight 0.11/50 stroke P Cylinder stroke 100 stroke P Locking weight 0.08 (Locking at head end, manual release non-locking style) 0.74+0.11X100/50+0.08=1.04kg All mounting bracket 0.11 0.16 0.26 0.27 0.42 0.56 Additional weight per 50 stroke Single knuckle 0.15 0.23 0.26 0.26 0.60 0.83 Accessories Double knuckle (with pin) 0.22 0.37 0.43 0.43 0.87 1.27 1.7-
The weight will increase by 1kg when option J [Automatic fluid filling] is selected. The weight will increase by 4kg when option T and MT [High head pump] are selected.
B T Y L Depth ED T 4-LD PA K 4-MM Counter bore depth C Thread depth M F QW PB N A E depth EK Q + Stroke G Z + Stroke Stroke adjustment screw (inner cover) LW A A HP H HL HA HA HI TA TA R 4-J Depth JK Thread depth PC (from counter bore surface) 2-P 2-Counter bore dia.
IDX-OM-W014-C / Series IDU3E-10(-C,K,L,M,R,S,T) IDU3E-20(-C,K,L,M,R,T) IDU4E-10(-C,K,L,M,R,S,T) IDU4E-20(-C,K,L,M,R,T) IDU6E-10(-C,K,L,M,R,S,T) IDU6E-20(-C,K,L,M,R,T) IDU3E-23(-C,K,L,R,T,V) IDU4E-23(-C,K,L,R,T,V) IDU6E-23(-C,K,L,R,T,V) URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC ISO4414 * 1) JIS B8370 *2 ) *1) ISO 4414
rate measurement range l/min Integrated type Display unit Display unit (4ch) Sensor unit PF2W504(T) PF2W520(T) PF2W540(T) PF2W511 PF2W704(T) PF2W720(T) PF2W740(T) PF2W711 0.5 to 4 2 to 16 5 to 40 10 to 100 PF2W30 PF2W20 PF2W33 For Deionized Water and Chemicals For Deionized Water and Chemicals P. 44 Remote type Flow rate measurement range l/min Display unit Display unit (4ch) Sensor unit
4-J Depth JK Thread depth PC (from counterbore surface) 2-P 2-Counterbore dia.
Description Material q w e r t Solenoid coil IN Armature assembly Stainless steel, HNBR, PPS Return spring Stainless steel O-ring HNBR Body Aluminum Bracket Assembly Dimensions J 1.5 A C 4-6 B D Valve mounting screws 2-H Valve mounting hole Bracket Mounting Dimensions/Bracket Material: Stainless Steel (mm) A B C D H J Assembly part no.
Through-hole/Both ends tapped common (Basic) S T R Q H (Rod size) AE (Rc, NPT, G) (2 locations) (Port size) E effective thread depth F Yh9 Z X 5.5 (The dimension on the opposite side is the same.) I (4 locations) 0.1 0.2 D G W AC (4 locations) (The dimension on the opposite side is the same.) A AA C J L L J K (4 locations) Flat washer With 4 pcs.
Note 3) Bowl assembly for AL30 to AL60 comes with a bowl guard (steel band material). 52 AL10 to 60 Dimensions AL10 AL20 L D Bracket (option) G F Port size K M A Port size C B R C J H OUT OUT IN OUT OUT IN B R P Min. clearance for maintenance Min. clearance for maintenance A AL50, 60 AL30, 40 L D D L Port size Bracket (option) Bracket (option) G F G F Port size M K M K E J C B R C B R H
A : Max. 3.5 AR20-A to AR25-A : Max. 4 AR30-A to AR40-06-A : Max. 8 Model Standard specifications Optional specifications Round type pressure Round type pressure gauge gauge (with color zone) Bracket mount Panel mount P1 P2 A B C D F J H J H J M N Q R S T U V W Y Z AR10-A M5 x 0.8 1/16 25 47.4 11 12.5 M18 x 1 12.5 26 26 25 28 30 4.5 6.5 40 2 18 18.5 AR20-A 1/8, 1/4 1/8 40 67.4 23.5 22
-J 1000 2000 3000 * P ease v sil our SMC homepage illpj,\i/rvw.smcwo d.com lor lhe atesl dela ls on our CE compl anl products.
. l b t t . l b kwh Volume ins 16387 in3 16.387 ft3 0.0283 ft3 28.329 gal(U.S.)3.785 Volume mm3 6.10 x 10-5 cm3 (cc) 0.0610 m3 35.320 L 0.0353 L 0.2642 Weight g 0.0353 kg 2.2046 1.356 N . m 1.356 J 3.6 l\rJ mm3 cm3 (cc) m3 L L rn3 in3 Energy ft3 N. m f t 3 J gar(u.s.)
C J G5-S Auto Switch Mounting Bracket Part No.
-r I tt""d lii9;--1@_*_1aru" l . 6 l y ' | t Fiif_ilri v *r T f l l T r I L---+---J-J--fo O Series NCM Auto Switeh Mounting Position aAuto $vidr Placemer* dr|lsidrs D-85, 86 Type Front Nose Mounting type Auto switch Auta Swifuh Pkrcement Dfinensions 0.97 1.03 1 . 1 2 1.22 1.35 '( ) are for Front Nos Mounting type cylinders.
r cl cl en nt er er e tm e m nt nt is us u t u w C 0 us o 90 k o c lo o C l dj C C 19 dj se c Cl 1 A k A A wi e w oc ge dj k A is oc k ng dj u wi e Cl an st us se ro ra m r ta t ot m r d at ti n e n io on e n e on nt e nt tio nd r r a a ti n n g ta e 5 9 g ta e 9 ro 5 ro m m u im u im ax M ax M Note) The drawing shows the rotation range of the positioning pin hole.
70 40 160 37 M8 165 85 12 9 125 110 176 160 16 18 107 50 75 150 115 82.5 45 194 42 M10 200 95 12 11 135 115 210 190 19 23 142 Bore size (mm) W WH W V U T S Z R Y Q X O P 20 25 32 40 50 30 23 36 40 86 12 26 140 12 80 21 30 M6 x 1 M5 x 0.8 30 25 44 47 98 13 31 153 12 80 21 37 M6 x 1 M5 x 0.8 25 28.5 50 53 112 16 38 161 12 82 21 37 M6 x 1 Rc 1/8 20 33 60 63 132 20 47 188 12 92 25 44 M8 x 1.25
Cup Calculation W: Lifting force [N] P: Vacuum pressure [kPa] S: Cup area [cm2] t: Safety factor Horizontal lifting: 4 or more Vertical lifting: 8 or more Theoretical lifting force table The theoretical lifting force (not including the safety factor) can be determined by the cup diameter and vacuum pressure.
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -