Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: 01 (R1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: R1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Draw a vertical line to the X axis from intersection B. The temperature at the intersection between this line and the X axis is the dew point (in this example, 13oC).
Ground wire (1.5 m)/Accessories IZH-A-01 High-voltage measuring handle/Option IZH-C-01 Soft case/Accessories IZH-B-01 High-voltage measuring handle Ground wire Soft case Note) Be sure to use a high-voltage measuring handle in situations such as during high-voltage measurement when there is a possibility of personnel coming in contact with electricity.
Orange mark X 2. Removing the handle To remove the handle, align the mark on the handle and the mark on the bonnet and then pull the handle. Table 1. Clearance Dimensions Orange mark ARG30 AWG30 ARG40 AWG40 ARG20 AWG20 mark mark X dimension (reference value) Bonnet 3.3 mm 3.3 mm 2.6 mm 3.
50 40 60 60 50 50 0 to 120 30 to 200 0 to 60 0 to 250 0 to 100 10 to 200 NBR Silicon rubber Urethane rubber Fluoro rubber Conductive NBR Conductive silicon rubber X X X X X X X X X X X X X X X X X X X X X X X The above table covers only general characteristics of subject rubber materials.
Q x R M8 x 1.25 x 16 M10 x 1.5 x 16 S 176 188 TB 14 14 TC x R W 60 70 X 60 70 ZZ 180 192 Model CY1B50 CY1B63 Mounting Nut/included (2 pcs.)
0.8 x 16 M5 x 0.8 x 20 M5 x 0.8 x 25 Dimensions ( ): Denotes the values of D-A44C (mm) D-A3C D-A44C 2 x M5 x 0.8 x 12 Hexagon socket head cap bolt Tightening gland 2 x M5 x 0.8 x 12 Hexagon socket head cap bolt Tightening gland G 1/2 G 1/2 4 x Z 4 x Z (Applicable cable O.D. 6.8 to 9.6) (Applicable cable O.D. 6.8 to 11.5) Hexagon socket head cap bolt Hexagon socket head cap bolt DIndicator
The load ratio is obtained by the following formula: ((Load mass x 9.8)/Theoretical output) x 100% Conditions Base mounted CJ2 series CM2 series MB, CA2 series CS1, CS2 series Tube x Length T0604 x 1 m T1075 x 1 m T1209 x 1 m Speed controller AS3002F-06 AS4002F-10 AS4002F-12 Silencer AN40-04 AN40-04 Conditions [With SGP (Steel Pipe)] Body ported MB, CA2 series CS1, CS2 series Tube x Length
size 10, 13, 15 + with function plate For nozzle size 10, 13, 15 + with function plate M2.5 x 0.45 x 35 M2.5 x 0.45 x 39 M2.5 x 0.45 x 5 M2.5 x 0.45 x 8 M3 x 0.35 x 19 M3 x 0.35 x 23 M3 x 0.35 x 24 M3 x 0.35 x 28 M3 x 0.35 x 68 M3 x 0.35 x 72 M3 x 0.35 x 73 M3 x 0.35 x 77 y u Components Ejector unit + Vacuum switch/Filter unit i o For nozzle size 10, 13, 15 M3 x 0.35 x 84 4 [For ZSE4 spec