Pressure Momentary change P1 P2 Set value Anti-chattering function Devices such as large bore cylinders and high-flow vacuum ejectors consume a large volume of air when they operate, and this may cause a momentary drop in the primary pressure.
Note 1) Since static electricity may be generated, implement suitable countermeasures. Note 2) Use the nut material made of PFA because the nut material, PVDF can be used depending on the environment or temperature.
If the product is used in an environment or location conducive to corrosion, discoloration or deterioration due to corrosion may occur. 2. Fatigue damage may occur if the product is used in a location subject to vibrations or impacts. Selection Warning 1.
The period may vary depending on the temperature and other conditions. In some cases the absorber may need to be replaced before the allowable operating cycle above. -X Individual -X 533
The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3.
Note 1) Since static electricity may be generated, implement suitable countermeasures. Note 2) Use caution as permeation may occur. The permeated fluid may effect the parts of other materials. Table symbols : Can be used : Can be used in certain conditions Compatibility is indicated for fluid temperatures of 60C or less.
Note) It may be difficult to replace the cushion seal #6. Seal kit includes a grease pack (10 g). Order with the following part number when only the grease pack is needed.
Be sure to flush the piping to prevent foreign matter from entering the positioner before connecting them. *1 If the restrictor is clogged, the cylinder rod may not perform a stroke or hunching and overshoot may occur. 153
IZN IZF It may cause human injuries and damage. 2. Use the device in the condition of specified range. ZVB Using it out of the specified range may result in fires, electric shock, or damage. Confirm the specifications before using. 2. Handheld electrostatic meters do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion.
In particular, polyurethane tubing may fold when inserted due to its softness. Hold the end of the tubing, and insert it all the way in slowly and securely. Refer to dimension M in the dimension drawings for guidance on the insertion depth of tubing. 2.
Excessive impact may damage the switch inside. 4. During installation or removal of the sensor, use a wrench on the Hex.width across flats for PT threads. For M5 thread, use it on the rectangular parts beneath the body. If force is applied to the top of the body or resin case, damage may be caused to internal parts of the switch. 5.
Excessive impact may damage the switch inside. 4. During installation or removal of the sensor, use a wrench on the Hex.width across flats for PT threads. For M5 thread, use it on the rectangular parts beneath the body. If force is applied to the top of the body or resin case, damage may be caused to internal parts of the switch. 5.
Note 2) Since the body and table are constructed with a magnetic substance, it becomes magnetized when magnets, etc. are attached to them, and this may cause the auto switch malfunction. Note 3) If workpiece holding bolts are used, they can touch the body and cause malfunctions, etc.
Element oil saturation-Initial condition Note) Compressed air over max. flow line in the table below may not meet the specification of product. It may cause damage to the element.
Note 3) Inlet pressure: 0.7 MPa Use caution not to supply air more than the rated amount, otherwise oil may flow to the outlet side. Accessory (Standard)/Part No. AMR3000 AMR4000 AMR5000 AMR6000 Model Model name Bracket 13576 13556 13587 13568 (5)(6) G36-1001 G46-1002 Pressure gauge 1.0 MPa Accessory (Option)/Part No.
Unintended operation may result. 2. Do not apply strong shocks (over 300 m/s2) to the pressure switch to prevent the switch from damage. AV AU AF Caution Flow rate (/min (ANR)) Inlet pressure (MPa) 1. Release the lock to adjust the pressure. After the adjustment, engage the lock.
Sudden pressure fluctuations may shorten the durability of the pressure gauge.
Since the sensor for stroke reading cylinder adopts the magnetic method, it may result in malfunction if there is a strong magnetic field around the sensor. Use it under the external magnetic field with 14.5 mT or less.
It may vary substantially depending on an ambient environment. 665 CE1 Series Auto Switch Mounting Bracket: Part No.
A bending moment will be applied to the cylinder due to the vibration generated at the stroke end, and the cylinder may be damaged. In such a case, mount a bracket to reduce the vibration of the cylinder or use the cylinder at a piston speed low enough to prevent the cylinder from vibrating at the stroke end.