Coil rated voltage 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 1 2 3 Electrical entry 110 to 120 VAC, 50/60 Hz T E H G Grommet (Lead wire: 300 mm) Grommet (Lead wire: 600 mm) 4 220 VAC, 50/60 Hz 5 6 24 VDC 12 VDC Grommet terminal Conduit terminal D With connector DO Without connector L With lead wire LN Without lead wire LO Without connector M With lead wire MN Without lead wire 7 240 VAC, 50/60
Component Parts Operation principles
Air Cylinders Drive System Full Stroke Time and Speed at the End Air Cylinders Drive System Full Stroke Time and Speed at the E . Precautions. Environment. Manual Override Operation. Exhaust Restriction. Series SV Used as a 3 Port Valve . Light/Surge Voltage Suppressor. Light Indication. Connector Entry Directions. How to Order Manifold. Substrate Assemblies inside Manifolds .
Platinum silver Body C: Conduit VS4010-CSSub-plate Platinum silver Aluminum die-casted w T: Conduit terminal VS4010-TSSpool/Sleeve Stainless steel e U: Grommet, D: DIN terminal VS4010-SReplacement Parts Part no. No.
Series: 1 (JSY1000), Type: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: 0 (w/o SI Unit), SI Unit Common, End Plate: w/o SI Unit, I/O Unit Stations: None, Valve Stations: 2 Stations, P,E Port, SUP/EXH Assembly: E (Internal Pilot, Built-in Silencer; D Side, 2 to 10 Stations), A,B Port Size: C4 (ø4 One-touch Fitting)
Please contact us for the latest version.sales@ocaire.com IT4000/ITV3000 E/P REGULATOR. E/P REGULATOR. INSTRUMENTATION. IT4000 1/4 INC(MISC./OTHER). 1.80779 lb. DX.
Please contact us for the latest version.sales@ocaire.com IT4000/ITV3000 E/P REGULATOR. E/P REGULATOR. INSTRUMENTATION. IT4000 1/2 INCNPT VERSION. 1.42198 lb. FB.
B N.O. 1/2 G 15 With surge voltage suppressor C 110 VAC Stainless steel D 200 VAC 5 20A H C37 N.C. 3/4 20 E 230 VAC C N.O. J Stainless steel F 24 VDC 6 25A N.C. K C37 Stainless steel 1 25 G DIN terminal 24 VDC D N.O.
: 08 [ø8 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: E (Vacuum Break Flow Adjustment Needle Screwdriver Operation Long Lock Nut Type)
Please contact us for the latest version.sales@ocaire.com IT4000/ITV3000 E/P REGULATOR. E/P REGULATOR. INSTRUMENTATION. IT4000 1/2 INCNPT VERSION. 1.42198 lb. FB.
(Push-turn Locking Lever Type), Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: B (PNP Open Collector), Unit: w/Unit Switching Function, Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)
Series: SS5Y3 (SY3000 Manifold), Model: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: EB (EtherNet/IPâ„¢, IO-Link Unit), SI Unit Common, End Plate: 4 (Negative Common, M12 Connector), I/O Unit Stations: None, Valve Stations: 7 Stations, P,E Port, SUP/EXH Assembly: E (Port Location D Side, Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting), Mounting: A (DIN
Series: SS5Y3 (SY3000 Manifold), Model: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: EB (EtherNet/IPâ„¢, IO-Link Unit), SI Unit Common, End Plate: 4 (Negative Common, M12 Connector), I/O Unit Stations: None, Valve Stations: 7 Stations, P,E Port, SUP/EXH Assembly: E (Port Location D Side, Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting), Mounting: AA (Direct
(Push-turn Locking Lever Type), Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: B (PNP Open Collector), Unit: w/Unit Switching Function, Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)
Dimensions (Port size) Semi-standard specifications With element service indicator Clearance for maintenance Optional specifications With auto Standard specifications Model Bracket mount drain P A B C D E G J M N Q R S T U V B AF20-D 1/8, 1/4 40 87.6 17.5 21 25 21 30 27 22 5.4 8.4 60 2.3 28 104.9 AF30-D 1/4, 3/8 53 115.4 21.5 26.5 30 35 26.5 41 35 25 6.5 13 71 2.3 32 157.1 AF40-D 1/4, 3/8
Model: 12S (Top-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - M12 Connector), SI Unit Output Polarity: N (Negative Common), Valve Stations: 6 Stations, P, E Port Location: U (U Side), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), P, E Port Size: N (ø5/16"), Mounting: D (DIN Rail Mounting, w/DIN Rail), DIN Rail Option: 7 (for 7 Stations; Longer
Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: B (PNP Open Collector), Unit: w/Unit Switching Function, Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)
Series: 3 (JSY3000), Type: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: 0 (w/o SI Unit), SI Unit Common, End Plate: w/o SI Unit, I/O Unit Stations: None, Valve Stations: 3 Stations, P,E Port, SUP/EXH Assembly: E (Internal Pilot, Built-in Silencer; D Side, 2 to 10 Stations), A,B Port Size: C8 (ø8 One-touch Fitting), Mounting: D (DIN Rail Mounting), DIN Rail Option: 0 (DIN Rail Mounting
Series: 3 (JSY3000), Type: 10S6 (Side-Ported, Serial Interface, EX600), SI Unit: EB [EtherNet/IPâ„¢ IO-Link Unit], SI Unit Common, End Plate: 7 (Power Supply w/M12 Connector, PNP, IN/OUT Pin Arrangement 1), I/O Unit Stations: None, Valve Stations: 2 Stations, P,E Port, SUP/EXH Assembly: E (Internal Pilot, Built-in Silencer; D Side, 2 to 10 Stations), A,B Port Size: C8 (ø8 One-touch Fitting
Series: 1 (JSY1000), Type: 10S (Side-Ported, Serial Interface, EX250), SI Unit: ZE (EtherNet/IPâ„¢, Negative Common), Input Block Stations: 3 Stations, Input Block Type: E (NPN Sensor Input, M12, 4 Inputs), Valve Stations: 5 Stations, P,E Port, SUP/EXH Assembly: C (Internal Pilot, Built-in Silencer; U Side, 2 to 10 Stations), A,B Port Size: C6 (ø6 One-touch Fitting)