(Do not cut the tube with plier6, nippers, scissors, utilitv knife, etc.) ePull out the tube while keeping the release button depressed. lJf the release butlon is nol held down, the tube cannot be withdrawn.) OGrasp the tube, then slowly push it until il comes lo a dead-end.
When reassembling, do the opposite. Type 01T Wth Terminal Block Wirins . Remo\ junction cover of manifold to expose terminal block attached to the manilold block. Lead wires from solenoid valve are connected with the terminals on the upper side of the terminal block.
F: 2.08 0.13 Bore size (mm) Cylinder basic weight Standard Stroke CLK2G series CLK2P series Additional weight per 25 mm stroke Bore size (mm) 40, 50, 63 Standard stroke (mm) 50, 75, 100, 125, 150 Single knuckle joint Double knuckle joint (Pin, cotter pin, flat washer are included.) 0.36 0.34 0.22 0.12 0.24 2.04 Limit switch mounting base Dog fitting Foot Pedestal Note) The above values do
Do not use the body A in a continuously rotating place. AQ Body B AS100P AS200P AS250P AS300P Model Rod and applicable tubing O.D. (Metric size) ASV 4 6 6 10 8 4 Flow rate [L/min (ANR)] It may damage the body A or fittings.
(Scratches, scrapes, blotches and uneven color may be present as long as they do not interfere with function or performance.) The symbol refers to surface finishing of JIS G 4305 cold rolled stainless steel sheet. 47 B
Note 3) Do not cut the tube. 1 Use the product in an operating environment where humidity is as low as possible. 2 The value at which the moisture control tube is bent or flattened at 20C. Be careful not to bend or flatten the tube and the inner sleeve even if the value is more than the minimum bending radius. 2 Inner sleeve R How to Order IDK 02 100 Moisture control tube O.D.
Do not indicate suffix N for no lead wire on D-A3/A44/G39/K39 models. (Example) M9NW (Example) M9NWM (Example) M9NWL (Example) M9NWZ (Example) H7CN Since there are other applicable auto switches than listed, refer to page 1040 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785.
All single wiring Single and double mixed wiring When there are stations which do not require wiring (e.g. single SUP spacer), specify the wiring specification in the manifold specification so that the number of the solenoids is 16 maximum.
Model Pressure range *1 Indication unit Connection thread Note MPa Port size 01 Rc1/8 02 Rc1/4 R1/8 R1/4 G46-7-02-SRB 0 to 0.7 R1/4 G46-10-02-SRB 0 to 1.0 G46-4-01 to 02-SRB 0 to 0.4 MPa Set pressure range: 0.05 to 0.69 MPa 02 WR110 X215 *1: Do not apply more pressure than the max. pressure displayed. It may cause a malfunction.
Do not apply an impact or large forces to a pad when adsorbing a workpiece. This will cause deformation, cracking and wear of the pad to be accelerated. The stiffening ribs, etc. should touch lightly, while staying within the pad skirt's deformation range. Positioning should be performed accurately. Especially in the case of small diameter pads. 6.
When mounting the product, please do not block the exhaust port at the center of the body as this may cause performance issues.
Do not introduce air from the outlet side as this can damage the damper. 1. Use a check valve (Series AKM) to prevent back flow of the lubricant when redirecting the air flow before the lubricator. AL40 Rc 1/2 Caution 0.1 Pressure drop (MPa) 0.08 P1 = 0.7 MPa P1 = 0.5 MPa P1 = 0.1 MPa P1 = 0.3 MPa Maintenance 0.06 Warning 0.04 1.
Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: K (High-pressure, 1MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115 VAC) 50/60Hz], Lead Wire: DO (DIN Connector w/o Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread: T (NPTF)
Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: K (High-pressure, 1MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: DO (DIN Connector w/o Connector), Light/Surge Suppressor: S (Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8)
When piping and fittings, etc. are being screwed together, be certain that cutting chips from the pipe threads, sealing material, and other debris do not get inside the piping. Further, when pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the pipe. 3. The unit should be mounted vertically. 4.
/set) do not include a grease pack (10 g), order it separately. Grease pack part no.: GR-S-005 (5 g) 7
Model: 1 (Size 1), Orifice Size: 1 (ø2), Fitting Size: 2 (1/4), Fitting Type: S (Compression Fitting), Voltage: 5 (24 VDC), Electrical Entry: DO (DIN Terminal w/o Connector, w/Surge Voltage Suppressor)
Model: 3 (Size 3), Orifice Size: 4 (ø6), Fitting Size: 3 (3/8), Fitting Type: S (Compression Fitting), Voltage: 5 (24 VDC), Electrical Entry: DO (DIN Terminal w/o Connector, w/Surge Voltage Suppressor)
Model: 2 (Size 2), Orifice Size: 3 (ø4.5), Fitting Size: 2 (1/4), Fitting Type: N (NPT Female Thread), Voltage: 5 (24 VDC), Electrical Entry: DO (DIN Terminal w/o Connector, w/Surge Voltage Suppressor), Special Electrical Entry: A (90°)