Minimum Stroke for Auto Switch Mounting (mm) D-M9 10 D-M9V 5 D-M9W 15 D-M9WV 10 D-A9 10 D-A9V 5 Bore size (mm) 321, 40 502, 63 No. of auto switch mounted With 1 pc. 10 5 15 15 10 10 With 2 pcs. 1 The outline dimensions for 5 mm stroke will be the same as those for 10 mm stroke. 2 The outline dimensions for 10 mm stroke will be the same as those for 15 mm stroke. 10 Prior to Use Auto Switches
A A1 E1 L1 MM U1 NZ L 0.2 0.4 +0.058 0 +0.058 0 +0.4 +0.2 +0.058 0 8 IY-G02 8 20 I-G02 34 8.5 16 25 M8 x 1.25 10.3 11.5 8.5 16 25 M8 x 1.25 10.3 11.5 16 21 Y-G02 8 8 20 34 0.2 0.4 +0.058 0 +0.4 +0.2 10 IY-G03 10 25 I-G03 20 M10 x 1.25 20 M10 x 1.25 41 10.5 30 12.8 14 10.5 30 12.8 14 20 25.6 Y-G03 10 10 25 41 +0.5 +0.3 0.3 0.5 +0.058 0 +0.070 0 +0.070 0 +0.058 0 10 IY-G04 18 32, 40 I-G04 M14
A A1 E1 L1 MM U1 NZ L 0.2 0.4 +0.058 0 +0.058 0 +0.4 +0.2 +0.058 0 20 I-G02 Y-G02 20 8 IY-G02 8 34 8.5 16 25 M8 x 1.25 10.3 11.5 8.5 16 25 M8 x 1.25 10.3 11.5 16 21 8 8 34 0.2 0.4 +0.058 0 +0.4 +0.2 25 I-G03 Y-G03 25 10 IY-G03 10 20 M10 x 1.25 20 M10 x 1.25 41 10.5 30 12.8 14 10.5 30 12.8 14 20 25.6 10 10 41 +0.5 +0.3 0.3 0.5 +0.058 0 +0.070 0 +0.070 0 +0.058 0 32, 40 I-G04 Y-G04 32, 40 10
A A1 E1 L1 MM U1 NZ L 0.2 0.4 0.2 0.4 +0.058 0 +0.058 0 +0.4 +0.2 +0.058 0 20 I-G02 Y-G02 20 8 8 IY-G02 34 8.5 16 25 M8 x 1.25 10.3 11.5 8.5 16 25 M8 x 1.25 10.3 11.5 16 21 8 8 34 +0.058 0 +0.4 +0.2 25 I-G03 Y-G03 25 10 10 IY-G03 41 10.5 20 30 M10 x 1.25 12.8 14 10.5 20 30 M10 x 1.25 12.8 14 20 25.6 10 10 41 +0.5 +0.3 0.3 0.5 0.3 0.5 0.3 0.5 +0.058 0 +0.070 0 +0.070 0 +0.058 0 32, 40 I-G04
to 10 (832) Integrated time setting; -10 to 10 (833) Differentiation time setting; -10 to 10 Table 13 Amount of change when set value is increased/ decreased by 1 Set value is 0 or more Set value is less than 0 Prop. gain 10% 10% Integ. time 50% 10% Deffer. time 10% 10% 8: When automation calibration is performed, PID constant is automatically set.
Bore size (mm) Part No. d l Cotter pin d m H B Dd9 L C D (Cut through) Note 1) 3 x 18l 4 x 25l 4 x 35l 10 14 22 32, 40 50, 63 80, 100 32 40 50, 63 80 100 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 36 51 72 4 4.5 5 6 8 11 13 16 17 22 27 32 41 44 60 82 19.6 25.4 31.2 37.0 47.3 16.5 21 26 31 39 CD-M03 CD-M05 CD-M08 NT-03 NT-04 NT-05 NT-08 NT-10 0.040 0.076 0.050 0.093 0.065 0.117 3 4
3Ybore size 63 63 all types 4 x 28AW 30 10 14 6 M18 x 1.5 80 32 23 43 16 35 65 30 18.3 80 80 all types 100, 125 all types 4 x 36AW 35 10 14 7 M22 x 1.5 95 36 28 50 16 39 78 35 22.3 N M L E F 100 5 x 40AW 42 10 15 8 M27 x 2 110 40 33 59 20 46 90 43 27.5 160 160 all types 5 x 50AW 50 10 15 10 M33 x 2 120 44 37 66 22 50 100 45 34 C D Spring pin hole Drilled after assembly P A 100 Series CHA
Note 16-9-5 16-10-1 Page 16-9-1 16-9-3 For details, refer to Best Pneumatics Vol. 16. 17-5-178 17-5-179
CD-MU02 Z 142.5 159 171 205.5 LX RR 8.5 10 11 16 LD LU 11 14 15 20 LC 16 18 20 28 Z LB 27 31 36 46 LB 27 31 36 46 LX RR 8 10 10 16 LA 35.5 41 47 62 ZZ 151 169 182 221.5 L 52.5 59 67 81 LA 35 41 46 62 LD LU 13 14 17 23 ZZ L 52.5 59 67 81 Model MLU25 MLU32 MLU40 MLU50 Model MLU25 MLU32 MLU40 MLU50 +0.4 +0.2 +0.4 +0.2 +0.4 +0.2 +0.4 +0.2 The L, Z and ZZ dimensions are reference dimensions when
CD-MU02 Z 142.5 159 171 205.5 LX RR 8.5 10 11 16 LD LU 11 14 15 20 LC 16 18 20 28 Z LB 27 31 36 46 LB 27 31 36 46 LX RR 8 10 10 16 LA 35.5 41 47 62 ZZ 151 169 182 221.5 L 52.5 59 67 81 LA 35 41 46 62 LD LU 13 14 17 23 ZZ L 52.5 59 67 81 Model MLU25 MLU32 MLU40 MLU50 Model MLU25 MLU32 MLU40 MLU50 +0.4 +0.2 +0.4 +0.2 +0.4 +0.2 +0.4 +0.2 The L, Z and ZZ dimensions are reference dimensions when
CD-MU02 Model MLU25 MLU32 MLU40 MLU50 Model MLU25 MLU32 MLU40 MLU50 Z 142.5 159 171 205.5 LX RR 8.5 10 11 16 LD LU 11 14 15 20 LC 16 18 20 28 Z LB 27 31 36 46 LB 27 31 36 46 LX RR 8 10 10 16 LA 35.5 41 47 62 ZZ 151 169 182 221.5 L 52.5 59 67 81 LA 35 41 46 62 LD LU 13 14 17 23 ZZ L 52.5 59 67 81 +0.4 +0.2 +0.4 +0.2 +0.4 +0.2 +0.4 +0.2 The L, Z and ZZ dimensions are reference dimensions when
Detection method Heating type sensor (branch flow type) Rated flow range 10 to 1000 L/min 20 to 2000 L/min Instantaneous flow 10 to 1050 L/min 20 to 2100 L/min Set point range Accumulated flow 0 to 999,999,999,990 L Flow specifications Instantaneous flow 1 L/min 2 L/min Minimum resolution Accumulated flow 10 L Accumulated volume per pulse (Pulse width = 50 msec.)
YB-03 32, 40 80 9 6.5 10 18 50 d2 d1 YB-05 50, 63 120 11 6.5 12 22 60 L UT C UA (mm) Part No.
ARM 2500 05 A 02 G1 AV AU Accessory None (With plug) Nil G1 G2 Regulator for manifold AF G33-10-01 GA33-10-01 AR Pressure gauges are shipped together (but not assembled).
ARM 2500 05 A 02 G1 AV AU Accessory None (With plug) Nil G1 G2 Regulator for manifold AF G33-10-01 GA33-10-01 AR Pressure gauges are shipped together (but not assembled).
Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V Selects the analogue input range. (AXB cannot select the following ranges. -10..10 V/ -5..5 V/ -20..20 mA) -5..5 V -10..10 V -20..20 mA (AXA) Sets the analogue input device range. 0..10 V 2 Analogue input range Channel 0..5 V 1..5 V (AXB) 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.
L D d m t d H B C l 0.040 0.076 0.050 0.093 32, 40 C type 10 for shaft NT-04 IY-G04 32, 40 41.6 9.6 36.2 1.55 1.15 M14 x 1.5 8 22 25.4 C type 14 for shaft 10 50, 63 NT-05 IY-G05 50, 63 50.6 13.4 44.2 2.05 1.15 M18 x 1.5 11 27 31.2 14 Retaining rings are included.
L 10-1 . 10-1 10-2 . 10-1 10-3 (ADH4000-04) . 10-2 10-4 . 10-2 10-5 . 10-2 11 11-1 . 11-1 11-2 . 11-1 11-3 . 11-1 11-4 . 11-2 11-5 . 11-2 12 T 12-1 . 12-1 12-2 . 12-1 12-3 . 12-2 12-4 . 12-2 12-5 . 12-3 13 V 13-1 . 13-1 13-2 . 13-2 13-3 . 13-2 14 14-1 . 14-1 IDFA Series 2 IDX-OM-W017 i i i 1 () OFF 3 ON OFF i-1 IDFA Series i 1 IDX-OM-W017 i i-1-1 3 IDFA Series
.*2 Screw-in type Nil Without nozzle 01 Symbol Size Nil Rc3/8 N NPT3/8 F G3/8 50 mm IBG1-12-10-50 02 100 mm IBG1-12-10-100 03 150 mm IBG1-12-10-150 04 300 mm IBG1-12-10-300 11 Long nozzle*1 With S coupler/One-touch fitting 50 mm IBG1-12-10-50S 12 100 mm IBG1-12-10-100S 13 150 mm IBG1-12-10-150S 14 300 mm IBG1-12-10-300S Symbol Applicable tubing O.D. Part no.
9 16.2 70 + Stroke 122.2 + Stroke Rod end nut 43.5 Front flange type/RLQF63 60 80 9 92 108 4-9 41 55 + Stroke 18 114 + Stroke Rod end nut 43.5 Rear flange/RLQG63 60 80 4-9 41 55 + Stroke 9 8 113 + Stroke 92 108 Rod end nut 43.5 4-M8 x 1.25 Cap bolt Double clevis/RLQD63 8 Hole: 14 H10 Shaft d9 20 41 55 + Stroke 22 44 +0.4 +0.2 14 30 8 134 + Stroke 148 + Stroke -0.1 -0.3 Rod end nut 33.5 12