Solenoid: No.1 Solenoid, Body Size: 5 (20A), Style: 2 (Energized Closed/N.O.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 04 [1/2 (20A)], Thread: T (NPTF), Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor)
Solenoid: No.1 Solenoid, Body Size: 5 (20A), Style: 0 (Energized Open/N.C.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 04 [1/2 (20A)], Thread: T (NPTF), Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: S (Surge Suppressor)
Solenoid: No.1 Solenoid, Body Size: 5 (20A), Style: 0 (Energized Open/N.C.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 04 [1/2 (20A)], Thread: N (NPT), Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: S (Surge Suppressor)
Function: 5 (3 Position Pressure Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 04 (1/2), Thread: T (NPTF)
Size: 5 (Body Size 5), Style: 0 (Standard Formula), Operation: 1 (External Pilot Solenoid), Port Size: 04 (1/2), Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light+Surge Suppressor), Option: BG (Bracket+Gauge)
Size: 5 (Body Size 5), Style: 0 (Standard Formula), Operation: 0 (Air Operated Style), Port Size: 04 (1/2), Thread: T (NPTF)
Size: 5 (Body Size 5), Style: 0 (Standard Formula), Operation: 1 (External Pilot Solenoid), Port Size: 04 (1/2), Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light+Surge Suppressor)
Type of Actuation: 5 (3 Position Pressure Center), Manifold Type: 40 (Base Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: E (Push-turn Locking Manual Override), A, B Port Size: 04 (Base Mounted Sub-plate 1/2), Thread: T (NPTF)
Type of Actuation: 5 (3 Position Pressure Center), Manifold Type: 40 (Base Ported), Pilot: Internal Pilot, Specifications: T (Power Saver), Voltage: 5 (24VDC), Electrical Entry: MN (M Plug Connector w/o Lead Wire), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 04 (Base Mounted Sub-plate 1/2), Thread: N (NPT
Type of Actuation: 5 (3 Position Pressure Center), Manifold Type: 40 (Base Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 04 (Base Mounted Sub-plate 1/2), Thread: T (NPTF)
Function: 5 (3 Position Pressure Center), Body Option: 0 (Plug-in), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 04 (Sub-plate 1/2), Thread: T (NPTF)
Function: 5 (3 Position Pressure Center), Body Option: 0 (Plug-in), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted Style), Piping: Side, Port Size: 04 (Sub-plate 1/2), Thread: T (NPTF)
Function: 5 (3 Position Pressure Center), Body Option: 1 (Non Plug-in Centralized Lead Wire Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 04 (Sub-plate 1/2), Thread: T (NPTF)
Base Mounted Wiring: 01CD (Base Mounted Plug-in w/Multi-connector on D Side), Stations: 5 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2), Thread: T (NPTF), Control Unit: E (Air Release Valve), Voltage: 5 (24VDC)
Note) Inch size Metric size KE 23 01 1 8" 3.2 4 6 8 10 12 5 32" Control type 04 06 08 10 12 03 05 07 09 11 13 3 16" Meter-out Meter-in 0 1 AS-FG 1 4" 5 16" AS-FP 3 8" 1 2" With One-touch fitting AS-FM Note) For applicable tubing O.D. selection, refer to the Model on page 630. Use 1/8" tube.
Actuation Type: 5 (3 Position Pressure Center), Sealant: 0 (Metal Seal), Function: Standard (1W), Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2), Thread: T (NPTF)
Actuation Type: 5 (3 Position Pressure Center), Sealant: 1 (Rubber Seal), Function: RY (External Pilot, Low Wattage 0.5W), Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2), Thread: T (NPTF)
Actuation Type: 5 (3 Position Pressure Center), Sealant: 1 (Rubber Seal), Function: Standard (1W), Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: W (IP65 Protection Compatible), 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2), Thread: T (NPTF)
Actuation Type: 5 (3 Position Pressure Center), Sealant: 1 (Rubber Seal), Function: Standard (1W), Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2), Thread: T (NPTF)