5 +10 7 5 < Cp 10 Cw 0.5 8 0 < Cw 5 9 5 < Cw 10 x Cp > 10 Cw > 10 > 5 [How to Perform a Test to Check the Performance] ISO 12500, which sets out the test method to be used in order to check the filter performance for each of the three kinds of contaminants, is indicated below.
U D-A79W D-F7WV D-F7V D-F7BAVL A B B A Proper auto switch mounting positions (mm) D-A7H, D-A80H D-A73C, D-A80C D-F7 D-F7V, D-F7W D-F7WV D-J79 D-J79C, D-J79W D-F7BA D-F9 D-F9V D-F9W D-F9WV D-A7 D-A80 D-A9 D-A9V D-A79W D-F7NTL D-F7F D-F9BAL Bore size (mm) A A A B A A A A B A B B B B B B 20 26 25 18 20.5 18.5 21 24 23 16 19 32 31 27.5 24.5 20.5 28.5 30 23 25.5 21.5 26 27 23.5 24.5 26 19 22 40
U D-A79W D-F7WV D-F7V D-F7BAVL A B A B Proper auto switch mounting positions (mm) D-A7H, D-A80H D-A73C, D-A80C D-F7 D-F7V D-F7W, D-F7WV D-J79 D-J79C, D-J79W D-F7BA D-F9 D-F9V D-F9W D-F9WV D-A7 D-A80 D-A9 D-A9V D-F7F D-F9BAL D-A79W D-F7NTL Bore size (mm) A B A A A A B A A A B B B B B B 20 20.5 11.5 21 18 25 26 12 9 16 17 32 27 20 27.5 24.5 31.5 26 19 30 29 32.5 20.5 17.5 24.5 23 22 25.5
B M3 x 0.5 (Piping port) 1.5 1.5 33 36 Manual override B P R R (35) 7 7 36 (2) 7 (13.5) 28.5 15 A 1 (Bleed port) 21 R2 P R1 13 4 8.2 15 10 10 10 M5 x 0.8 (Piping port) 11 14 14 15 (Bracket) 2 position double: SYJA3220-M3(-F) 2 position double: SYJA3240-M5 10 9 36 7.1 2 x M3 x 0.5 (Pilot port) 10 1.8 4 A B (For mounting) 2 x 3.2 1.5 1.5 22 7 8.2 2.5 (For manifold mounting) 2 x 1.8 2 x M3 x
VQZ Round head combination screw M1.7 x 14 7 Manual override VZ 7 14 P E P E 37.4 16 VS 29 32 43.8 VFN 4-PT 1/8 P , E port 2-3.5 Mounting hole 300 300 15.5 P = 10 1 2 3 4 5 n U side D side 40.2 15.5 46.2 19.4 A A 9.5 16.7 P = 10 n-M5 x 0.8 A port Dimensions Formula: L1 = 10n + 21, L2 = 10n + 7, n: Station (Max. 20 stations) n L L1 L2 2 41 27 3 51 37 4 61 47 5 71 57 6 81 67 7 91 77 8 9 10
Select a robotic cable (flexible cable) when repeated bending of the actuator cable is required. Also, do not put cables into a flexible moving tube with a radius smaller than the specified value (50 mm or longer). Electric shock, wire breakage, contact failure, or a loss of product control may occur if standard cables are used for repeated bending. 10. Confirm wiring insulation.
A A Solid state auto switch D-M9B, D-M9N Reed auto switch D-A93 (mm) (mm) Stroke (mm) 20 41 29 47 35 Stroke (mm) 20 45 25 51 31 Auto switch operating range Auto switch operating range 15 40.5 20.5 Model Model 25 50.5 30.5 30 59 39 10 35 15 25 46.5 34.5 30 55 43 10 31 19 15 36.5 24.5 A B A B A B A B A B A B 11-/22-MXP10 11-/22-MXP10 11-/22-MXP12 11-/22-MXP12 3 5 11-/22-
D L1 VMG KN KN 861 KN Series Nozzle for One-touch fitting/KN (mm) Model Nozzle size D Applicable fitting size d L1 A Weight (g) KN-Q06-100 KN-Q06-150 KN-Q06-200 KN-Q08-150 KN-Q08-200 KN-Q10-200 KN-Q10-250 KN-Q12-250 KN-Q12-300 5 5 5 9 9 16 16 23 23 18 18 18 20.5 20.5 22 22 24 24 35 35 35 39 39 43 43 45.5 45.5 6 6 6 8 8 10 10 12 12 1 1.5 2 1.5 2 2 2.5 2.5 3 D 10 A Connecting products with
2-M3 x 0.5 (Plug: M-3P) 6 (fitting seat surface dimension) 170.05 M3 x 0.5 Vacuum suction port Stroke: S M 1 Mounting base side B D Piping port 2-M3 x 0.5 A 5 5.5 A 3.2 J 2.4 Z Section AA 3.5 Depth 2 2.5 +0.030 0 7 +0.030 0 Depth 2 2.5 Q QL 11-/22-MXPJ6-10 4M3 x 0.5 depth 3 F (mm) E F H J M Q QL S Z Model 23 25 38 27 37 28 8 5 44 11-/22-MXPJ6-51 30 35 53 42 47 37 11 10 59 11-/22-MXPJ6-10
Note 3) A particulate generation test has been conducted in a vacuum environment of 10-Pa. a t e l u g c 2 Stainless steel linear guide & low particulate generation vacuum grease e i t n r a e p r a 0.0 10 0 20 10 w t i o o n L Operation cycles a t e l u g c e 1 i t n r a e Particulate generation from the linear guide unit has been reduced with the use of a stainless steel linear guide and
L D d m t d H B C l IY-G04 IY-G05 C type 10 for shaft 41.6 50.6 9.6 13.4 36.2 44.2 1.55 2.05 1.15 1.15 M14 x 1.5 M18 x 1.5 8 11 22 27 25.4 31.2 C type 14 for shaft 10 14 -0.040 -0.076 -0.050 -0.093 9-12-19 20 Simple Joint: 32 to 63 Type A Mounting Bracket 2-D T1 T2 M W V U F B E (mm) Joint and Mounting Bracket (Type A, Type B) Part No.
20 25 30 Operating pressure [MPa] Cylinder output F[N] Load weight [kg] 150 15 Allowable side load on the piston end Unit: N 100 10 Stroke of linear part Size 40 40 50 4 5 5 10 15 20 25 30 40 50 75 100 32 40 32 14 14 13 13 13 12 12 11 10 9 20 25 30 2 2.5 3 23 23 22 21 21 20 19 18 16 15 2) Using the cylinder body installed vertically: To operate the rotary cylinder with the cylinder body
It can be set at a minimum of every 0.01 deg.C. Host STX 36H Offset ETX Check sum CR Symbol 100 10-1 10-2 () () Thermo-con ACK CR Note)As for symbols, minus is indicated by -(=2DH) and plus is indicated by 0(=30H).
VQZ Plug Lead Unit U Type (Large Flow Capacity) Mounted Manifold (VV3Q12U) VZ L1 L2 7 4-PT1/8 VS P, E port 7 16 P E P E 29 14 7 32 40.1 49.8 300 Round head screw M1.7 X 14 2-3.5 Mounting hole Manual override 15.5 P=10 300 n 5 4 3 2 1 U side D side 46.5 35.2 19.4 15.5 A A 9.5 16.7 P=10 n-M5 A port Dimensions Equation: L1=10n+21 L2=10n+7 n: Station (Max. 20 stations) n L L1 L2 1 31 17
If a moment or torque directly acts on the cylinder, it will lead to reduced service life or damage to machinery. 7 3 Position Cylinder Series RZQ Construction 13 24 21 3 2 1 6 4 8 7 10 19 22 20 12 23 11 9 5 23 18 14 16 17 15 22 Parts list No. 1 2 3 4 5 6 7 8 9 10 11 12 No. 13 14 15 16 17 18 19 20 21 22 23 24 Note Note Description Material Description Material Hard anodized Aluminum alloy
A B A B B A B A B 16 (24) A B Hs Hs Hs 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 20 4.5 8 6 10 9 3 24.5 27 27.5 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 16 (24) 25 4.5 8 6 10 9 3 27 29.5 30 22.5 (30.5) 21.5 (29.5) 15.5 (23.5) 18.5 (26.5) 20.5 (28.5) 17 (25) 32 5.5 9 7 11 10 4 30.5 33 33.5 25 (34) 24 (33) 20 (27) 21 (30) 23 (32) 19.5 (28.5) 40 10 13.5 35 37.5
A B A B B A B A B 16 (24) A B Hs Hs Hs 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 20 4.5 8 6 10 9 3 24.5 27 27.5 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 16 (24) 25 4.5 8 6 10 9 3 27 29.5 30 22.5 (30.5) 21.5 (29.5) 15.5 (23.5) 18.5 (26.5) 20.5 (28.5) 17 (25) 32 5.5 9 7 11 10 4 30.5 33 33.5 25 (34) 24 (33) 20 (27) 21 (30) 23 (32) 19.5 (28.5) 40 10 13.5 35 37.5
Check that a pressure above 3.5%F.S. was not applied, during zero-clear operation. Product failure Replace the product. -49NO.ZL3-OM00701-A Error No. Problem Possible cause Investigation method Countermeasure Incorrect power supply Check if the power supply voltage is in the range 24 VDC 10%. Supply power supply voltage of 24 VDC 10%.
(mm) 2(A) 2(A) Applicable tube O.D. (mm) 2(A) Port size R(PT) 2(A) Port size R(PT) 1(P) 1(P) 1(P) 4 6 8 10 12 M5 1 8 1 4 3 8 1 2 1 8 1 4 3 8 1 2 4 6 8 10 12 1(P) M5 M5 4 M5 4 Tube O.D. (mm) Tube O.D.