Magnet: D (Built-in Magnet), Mounting: B (Through-hole, Standard), Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m

Magnet: D (Built-in Magnet), Mounting: B (Through-hole, Standard), Bore Size: 80mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m

Magnet: D (Built-in), Mounting: B (Through Hole), Bore Size: 25mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 25mm, Body Option: Standard, Locking Direction: F (Forwarding Stroke Lock), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 10 mm, Rod End Thread: With Thread, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, 0.5M, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 15 mm, Rod End Thread: With Thread, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M

Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 15 mm, Rod End Thread: With Thread, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M

Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 10 mm, Rod End Thread: With Thread, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M

Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 10 mm, Rod End Thread: With Thread, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 20 mm, Rod End Thread: With Thread, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)

Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 20 mm, Rod End Thread: With Thread, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 20 mm, Rod End Thread: With Thread, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M

Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 10 mm, Rod End Thread: With Thread, Auto Switch: M9BW--Solid State, 2 color Indication, 2 Wire, 0.5M, Lead Wire or Prewired Connector: Z (5m)

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: A93, Lead

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: A93, Lead

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9N, Lead

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: A93,

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9B,