Magnet: Built-in Magnet, Mounting: Axial Foot, Bore: 32mm, Stroke: 75mm, Action: Single Acting, Spring Return, Rod End Thread: Male Rod End, Pivot Bracket: -, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Mounting: Axial Foot, Bore: 32mm, Stroke: 75mm, Action: Single Acting, Spring Extend, Rod End Thread: Male Rod End, Pivot Bracket: -, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.23 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.18 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.23 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 200, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.18 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(

Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Bore Size: 32mm, Port Thread: Rc, Stroke: 300mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End

A93V A93 V V V No 100 V or less A90V A90 A90V A90 V V IC circuit Relay, PLC 24 V 12 V 2-wire Yes C73C A73C V V V V Connector No 24 V or less C80C A80C V V V V IC circuit Diagnostic indication (2-color indication) Grommet Yes A79W V V Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.

(M)(L)(Z) D-A93(M)(L)(Z) M9// Without auto switch (with magnet) * Standard lead wire length is 0.5 m.

Note 4) Figures in ( ) in the table W are D-A93.

-X168 (Example) MY2H40G-599L-A93-XB10 Symbol Symbol 2 Long Stroke -XB11 4 Copper-free 20Available with long strokes exceeding the standard strokes.

Please contact SMC regarding water resistant types with the above model numbers. 2 1 m lead wire is only applicable to the D-A93. None N (Example) H7CN Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed above, refer to page 111 for details.

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

A water-resistant type cylinder is recommended for use in an environment which requires water resistance. *2 1 m type lead wire is only applicable to D-A93. * Solid state auto switches marked with v are produced upon receipt of order. * Do not indicate suffix N for no lead wire on the D-A3A/A44A/G39A/K39A models. * Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM

D-A90(V)/D-A93(V)/D-A96(V) Direct Mounting Style .

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, LE, 32MM CM2 DBL-ACT AUTO-SW, 3.08647 lb

Please consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked with p are produced upon receipt of order.

D-M9/M/9W/M9A Less than 20 stroke Note 2) Less than 55 stroke Note 2) D-A90/A93 Less than 50 stroke Note 2) Note 2) Minimum stroke for auto switch mounting in types other than those mentioned in Note 1. 152 Auto Switch Mounting CJ2Y Series Operating Range Auto Switch Mounting Brackets/Part No.

47 C 11 21 27 34.5 35.5 44.5 A 19.5 29.5 35.5 43 44 53 6 10 15 20 25 32 Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.