LVA Acetone 100% Note 1,2) LVH Ammonium fluoride 40% Ammonium hydroxide 30% LVD Butyl acetate 100% LVQ Methylne chloride 100% LVP Hydrochloric acid 38% LVW Hydrofluoric acid 50% LQ1 LQ1 Hydrogen peroxide 60% LQ3 LQ3 Methanol 100% LVN LVN Methyl ethyl Ketone Note 2) Nitric acid 70% LQHB LQHB Note 2) Phosphoric acid 86% TL TIL Caustic potash 85% TLM TILM Sulfuric acid 100% Note
Possible to use in vacuum to 100 kPa Applicable Tubing Tubing material FEP, PFA, Nylon, Soft nylon, Polyurethane Tubing O.D. 4, 6, 8, 10, 12, 16 Specifications Fluid Air, Water 1 Operating pressure range 2 100 kPa to 1 MPa Proof pressure (at 23C) 3 MPa Ambient and fluid temperature 5 to 60C, Water: 0 to 40C (No freezing) Thread Mounting section JIS B 0203 (Taper thread for piping) JIS B 0205
DXT170-176-2-01 DXT170-176-2-02 100V 200V 100 VAC 200 VAC DXT170-176-2-03 110V 110 VAC DXT170-176-2-04 220V 220 VAC DXT170-176-2-07 DXT170-176-3-51 DXT170-176-3-06 DXT170-176-3-05 DXT170-176-3-53 240V 6VD 12VD 24VD 48VD 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC Circuit with Indicator Light AC circuit DC circuit NL: Neon bulb R: Resister D: Protective diode LED: Light emitting diode R: Resistor 4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 800 700 600 500 400 300 200 100 0 VQC2000 800 700 600 500 400 300 200 100 0 VQC4000 Values at extension of a directly coupled cylinder when meter-out speed controllers are used with the needle full open.
OUT(2) 1 Thread type Rc NPT G Nil N F IN(1) Voltage 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Port size Class 3 Port size 1/8 (6A) 1/4 (8A) Class 2 Class 4 Symbol 01 02 03 04 06 3/8 (10A) 1/2 (15A) Class B in AC has a rectifying circuit built-in. Class H is AC only. No rectifying circuit.
mm2/s Hydraulic fluid 40 to 100 mm2/s DIN terminal DIN terminal with light/surge voltage suppressor Caution CE-compliant This product cannot be used for water application.
300 400 200 VXB215 B E(H) 100 300 400 500 600 200 VXB215 C F(H) 100 300 400 500 600 700 800 200 Flow rate Q [kg/h] How to read the graph The sonic range pressure to generate a flow rate of 300 kg/h is P1 0.3 MPa for the VXB215C F(H).
Absolute accuracy (77F) Current consumption 100 mA or less Enclosure IP67 (Manifold assembly) Standards CE marking, UL (CSA), RoHS recognition Weight 0.6 lbs (300 g) Note 1) M12 (4-pin) connector can be connected. Note 2) When input signal exceeds 22 mA, the protection function activates and the input signal is interrupted.
L/min 11 cm ) IN OUT PF3W504 PF3W520 (16 L/min ) (16 L/min ) (4 L/min ) (8 L/min ) [cm] [cm] PF3W540 PF3W511() (100 L/min ) (100 L/min ) (50 L/min ) (40 L/min ) (40 L/min ) (50 L/min ) [cm] [cm] -36No.PF-OMN0009CN-F PF3W521() (250 L/min ) (250 L/min ) [cm] -37No.PF-OMN0009CN-F PVC 3F.S.11 cm IN OUT PF3W511/521(PVC ) (100 L/min ) (250 L/min ) [cm] -38No.PF-OMN0009CN-F PF3W504S PF3W520S
S o.o t o.t 0.0 25 50 75 Inpul signal (%F.S.) o 25 50 75 100 InPUt signa ("/.F.S.)
Max Operating Pressure: 3 (3.5 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: 2 (Differential Pressure Indication Switch), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 20μm
LINE FILTER, FH, HYDRAULIC FILTER, 4.60000 lb
Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: None, Relief Valve: Relief Valve, Fluid: Petroleum, Element: Paper, Filtration: 5μm, Fluid Direction: -, Made to Order: -
Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: None, Relief Valve: None, Fluid: Phosphoric Ester, Element: Paper, Filtration: 5μm, Fluid Direction: -, Made to Order: -
Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: Differential Pressure Indication Switch, Relief Valve: Relief Valve, Fluid: Petroleum, Element: Paper, Filtration: 20μm, Fluid Direction: IN Right, Made to Order: -
Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 10 [1 1/4 Threaded, 32 (1 1/4) Flange SSA], Pressure Indicator: Differential Pressure Indication Switch, Relief Valve: Relief Valve, Fluid: Petroleum, Element: Paper, Filtration: 20μm, Fluid Direction: IN Right, Made to Order: -
Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: None, Relief Valve: None, Fluid: Phosphoric Ester, Element: Micromesh, Filtration: 40μm, Fluid Direction: IN Left, Made to Order: Non-standard Filtration
Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 12 [1 1/2 Threaded, 40 (1 1/2) Flange SSA], Pressure Indicator: None, Relief Valve: None, Fluid: Petroleum, Element: Micromesh, Filtration: 10μm, Fluid Direction: IN Left, Made to Order: Non-standard Filtration
Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 10 [1 1/4 Threaded, 32 (1 1/4) Flange SSA], Pressure Indicator: Differential Pressure Indicator, Relief Valve: Relief Valve, Fluid: Water-glycol, Emulsion, Element: Micromesh, Filtration: 149μm, Fluid Direction: IN Left, Made to Order: Non-standard Filtration
Type: Line Filter, Type: Line filter, Hydraulic fluid: Petroleum series, Connection Port Size: 1/2B, Nominal filtration(μm): 20, Differential pressure display: N/A, Relief valve: With Relief valve, O-ring nominal size: N/A, Structure / connection method: Screw-in, Operating pressure (max.)(MPa): 3.5, Element: Paper, Flow Direction: IN left, Made-to-order specifications: None (standard), Related