0.1 x mcos + msin P m P 0.1 x m + m P D 1.6 x D 5.0 x D 5.0 x m m mv P Pv m > mv P > Pv Determination of allowable load mass & pressure Inclined operation (Refer to page 8-16-8
x mcos + msin P m P 0.1 x m + m P D 1.6 x D 5.0 x D 5.0 x m m mv P Pv m > mv P > Pv Determination of allowable load mass & pressure Inclined operation (Refer to page 8-16-8
W Fulcrum L 189 Model Selection 3 Clamp arm 40 8.0 200 180 7.0 Distance from pivot point (inches) 160 Distance from pivot point (mm) 6.0 140 5.0 120 4.0 100 80 3.0 60 2.0 40 1.0 20 0 0 0 1 2 3 4 5 6 7 0 5 10 15 20 25 30 Load capacity (N) Load capacity (pounds) 50 6.0 200 5.5 180 Distance from pivot point (inches) Distance from pivot point (mm) 5.0 160 4.5 4.0 140 3.5 120 3.0 100 2.5 2.0 0
to 50) PTSF-(A5/AG1/A12/AG2/AG3) ZP3P-T (20 to 50) PTSF-(B5/B8) w T male thread adapter assembly (With gasket) p.3 p.3 Pad diameter Part no. 20 25 35 50 Dimensions ZP3PA-T1-A5 V V ZP3PA-T1-AG1 V V ZP3PA-T2-A12 V V ZP3PA-T2-AG2 V V ZP3PA-T2-AG3 V V p. 11 w T female thread adapter Pad diameter Part no. 20 25 35 50 Dimensions w T male thread adapter assembly w T female thread adapter
Flange type Electrical entry Symbol Type Applicable flange size Nil 16, 25, 40, 50, 63, 80 63, 80 Grommet (lead wire length 300mm) Grommet (lead wire length 600mm) L type plug connector M type plug connector G H L M D KF(NW) K(DN) Solenoid valve direction Left flange surface K L Solenoid valve action Rear flange surface Right flange surface Nil 2 position single 2 position double M W Note
0.5MPaP 200 200 40 100 100 32 30 40 50 30 40 50 40 25 20 32 Load weight: m (kg) Load weight: m (kg) 20 20 25 20 10 10 5 4 3 5 4 3 2 2 1 1 0.5 0.5 100 500 400 300 200 100 500 400 300 200 Maximum speed: V(mm/s) 1000 1000 Maximum speed: V(mm/s) Note: 1kg = 2.2046lb 1MPa = 1450psi 1in = 25.4mm 20
Description Material 1 Pipe PPS 2 O-ring FKM 3 Attachment Brass 4 Spacer FKM w e e w 8 LFE Series Dimensions Integrated display type LFE1/2/3 K Width across flats H I L 4 x O J 2 x Port size M C N D Q P 1.41 E A B F G 1 For integrated display type The electrical entry for lead wire and M12 connector does not rotate and is limited to only one entry direction.
w OUT side e OUT side IN side IN side EX260 Series EX600 Series Specifications Description Communication cable (With connector on one side) Field-wireable connector EX9AC010ENPSRJ (1 m) EX9AC020ENPSRJ (2 m) EX9AC030ENPSRJ (3 m) EX9AC050ENPSRJ (5 m) EX9AC100ENPSRJ (10 m) PCA1446566 PCA1446553 Part no.
20 Z ZZ (NN1) x H G H 5.5 11 11 5.5 B A 3.2 6.5 7 7 12 1 4 NN-M4 x 0.7 thread depth 8 B A 3H9 depth 2.5 +0.025 0 3H9 depth 2.5 +0.025 0 HA GA Section AA Section BB (mm) Model F 20 30 20 28 38 ZZ 64 74 84 106 122 M 42 52 62 84 100 Z 41.5 51.5 61.5 83.5 99.5 K 22.5 32.5 42.5 52.5 62.5 J 17 27 40 50 60 I 10 10 7 19 25 NN 2 2 3 3 4 H 25 35 20 30 24 G 6 6 11 13 17 HA 20 20 20 30 48 N 4 4 6 6 6
Set the connection range of PF2D5. 0: 4 L 1: 20 L 2: 40 L rAnG (PF2D5, Selection of connection range) Y U8 0x00 3 R/W (0) 0: PFA (PF2A5) 1: PFW (PF2W5) 2: PFd (PF2D5) 3: USEr (User setting) 4 R/W Setting of connection product Y U8 0x01 (1) Setting of connection sensor (For PF3W5) Y U8 0x00 0: FloW 1: tEMP 5 R/W (0) Unit (Selection of display unit, for PF2A5) Y U8 0x00 0: L 1: Ft 6 R/W (0)
However, please contact SMC for water-resistant products of 20 and 25. 2 1 m type lead wire is only applicable to D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Solid state auto switches marked with are produced upon receipt of order.
Lateral 0.2 0.1 200 300 500 100 Load point distance mm LJ1H20 LJ1H30 20 10 Lateral load 100% 10 5000 Lateral load 50% 5000 2000 Horizontal load 100% 2000 Horizontal load 50% 1000 Horizontal load 100% 1000 Horizontal load 50% 500 500 Amount of deflection m Amount of deflection m 200 200 100 100 50 50 20 20 10 Lateral load 100% 10 5 Lateral load 50% 5 Horizontal empty weight deflection 2 2
Note Conductor resistance /km, 20C 65 or less 1.5 m 3 m 5 m AXT100-DS25-015 10 Cable 25 cores x 24AWG AXT100-DS25-030 Voltage limit VAC, 1 min. 1000 AXT100-DS25-050 L For other commercial connectors, use a 25 pins type with female connector conforming to MIL-C-24308. Note) The min. bending radius of D-sub cable is 20 mm.
Models (mm) Internal volume (L) Number of arranged elements Weight (kg) Element length (L) Model N (Port size) G W A B C D E F H J K P 25 (1B) 40 (1 1/2B) 50 (2B) 20 (3/4B) 20 (3/4B) 500 4 250 20 70 15 330 216.3 230 490 660 965 80 120 25 (1B) 40 (1 1/2B) 50 (2B) 20 (3/4B) 20 (3/4B) 500 4 500 20 80 24 330 216.3 230 490 905 1220 80 120 25 (1B) 40 (1 1/2B) 50 (2B) 20 (3/4B) 20 (3/4B) 500 4
x PC F=q x PA+(e-q) x PC F=-q x PA+r x PB+(w-e) x PC F=q x PA q, w and e are piston areas.
(Including O-ring for element) 5 m EP910-005N EP020-005N EP120-005N EP220-005N EP820-005N 10 m EP910-010N EP020-010N EP120-010N EP220-010N EP820-010N 20 m EP910-020N EP020-020N EP120-020N EP220-020N EP820-020N Element size 55 x 90 74 x 117 74 x 195 88 x 282 119 x 280 Port size 03 (3/8B), 04 (1/2B) 06 (3/4B), 08 (1B) 10 (1 1/4B), 12 (1 1/2B) 16 (2B) 20 (2 1/2B), 24 (3B) FH FH HOW Note) For
10 0 10 20 30 0 20 40 60 Work load (W) kg Work load (W) kg Work load (W) kg 600 600 600 L2 M2 400 400 400 L2 mm L2 mm L2 mm Rolling Yawing W 200 200 200 L2 M2 0 10 20 30 0 20 40 60 0 2 4 6 8 10 Work load (W) kg Work load (W) kg Work load (W) kg W 3000 2000 2000 a=1000 a=1000 a=1000 2000 L3 mm L3 mm L3 mm L3 1000 1000 1000 a=2000 a=2000 W a=2000 a=3000 a=3000 a=3000 M3 a 0 20 40 60 0 2 4
Tubing size (O.D. x I.D.) mm: 12 x 9 IDG30 IDG50 0 m 20 1 m 19 3 m 17 5 m 16 Note) In cases other than above model numbers, if the tube length is 5 m or less, an increase of the outlet air at the atmospheric pressure dew point will be 1C or less. Refer to pages 14-19-28 to 29. Construction Refer to pages 14-19-30 to 31.
3 m 5 m None Solid state switches marked with are produced upon receipt of order.
(25P) kit, with 3.0 m cable D-sub connector (25P) kit, with 5.0 m cable Flat ribbon cable (26P) kit, without cable Flat ribbon cable (26P) kit, with 1.5 m cable Flat ribbon cable (26P) kit, with 3.0 m cable Flat ribbon cable (26P) kit, with 5.0 m cable Flat ribbon cable (20P) kit, without cable F kit U side D side 16 stations 1 to 12 stations 24 D side D-sub connector kit P kit Note 1)