Applicable model M-5N AS1000 Nipple Note) AS1000 with nipple: AS1000-M5-N How to Order M5 AS 1 000 Option Body size H (1) High temperature (5 to 80C) 1 2 3 4 5 M3, M5 standard L (2) Low temperature (30 to 60C) 1 8 1 4 , standard standard standard standard Note 1) AS5000 is available as special. AS1000 is not applicable.
SPECIFICATIONS (N)AR Model NAR1000 NAR2000 NAR3000 NAR4000 NAR5000 NAR6000 NAR2500 Port Size M5x0.8 18 14 14 38 14 38 38 12 34 1 1 B O D Y S I Z E Flow Rate ln/min* 100 550 2000 2500 6000 8000 10 Max Supply Pressure 1.5MPa / 220PSI 10 M5 20 18 14 25 14 38 30 14 38 40 38 12 14 50 341 60 1 Max Operating Pressure 1MPa / 145PSI Pressure Regulating Range 0.05-0.7MPa 0.05~0.8MPa/ 8~125PSI (AR*000
4E)-Ms, B3r Stationsn ) 2 6 a 9 '10 ll 13 14 16 t8 19 20 L-l 1.47 (47.5)2.24 2.70 (58) (68.5)(79) (89.5)3.94 000) 4.35 (n0.5) 4.76 \121) 5.18 03I.5) 5.59 (142) 6.00 (152.5) 6.42 0631 6.A3 (173.5) 7 .24 (184) 7.66 (194.5) 4.07 (205) 4.48 (215.5) 8.90 \2?6) 9.31 (236.s) u 1.56 (39.5)1.97 (50) 2.38 (60.5)2.& (?
Pressure setting of 7 Ps|{0.51kgflcmr} (lT1 000 only), 50 PSI{3.51 kg7cm,}, '|0O PSI{7.1kg cml are available in addition lo the existing pressure setting ol 15 PSIII.oftgtcmr), 72 PSI{5.1kg't cm'?), and l3O Ps|{9.2kgflqrr}. . The subdivided pressure range rmproves pfessure accuracy. . The change in zero span cor rol range improves the controlling ope.ation.
series sizes IRV1000: 60l/min (ANR) IRV2000: 100l/min (ANR) IRV3000: 150l/min (ANR) Setting sensitivity: 0.13kPa or less Modular filter can be used on the SET side Application Examples Suction of work pieces Solenoid valve Vacuum pump Tank IRV Filter Suction pad Work piece With single pressure Solenoid valve Vacuum pump IRV Tank How to Order Filter Suction pad With multiple pressures IRV 000
One-touch fitting SY560--C6 Closed center 3 position 102 109 155 Exhaust center Pressure center Single 72 76 99 2 position Double 88 95 141 C8 ( ) Closed center SY560--C8 8 One-touch fitting 3 position Exhaust center 94 101 147 Pressure center 4 Series SY3000/5000/7000 How to Order Port Block Assembly How to Order Pilot Valve Assembly C4 SY7000 13A Series SY3000 Series SY7000 SY114 5 G SY 3 000
(Ex.) 10-2 1.6MPaADH4 000-04 IDFA4E 15E1-23-L N.O() 1.6MPa 0.051.6MPa (Rc1/2IDFA3E to 11E) 25mm (Rc3/4IDFA15E1) 32mm (R1/2IDFA3E11E) (R3/4 X R1/2IDFA15E1) (R1/2) (L) IDFA Series 10-1 10 1 IDX-OM-W017 10 L 10-3 1. Rc1/2 1) R3/4: 28 30Nm R1/2 ,R3/4 2. 3. (27mm)(22mm) () () () 10-4 1. 2. 3.
Body sizes: 16, 25, 32, 40; Stroke range: 50 to 1200mmin 50mm increments; Maximum work load: 75 kg (horizontal); 25 kg (vertical); Maximum speed: 1500 mm/s (H lead, size 25); Maximum acceleration: 10, 000 mm/s² (horizonal); 5,000mm/s² (vertical); Positioning repeatability: ±0.02mm (±0.015mm high precision type); Motor type: 24 VDC step motor with battery-less absolute encoder
I/O and actuator cables are also identical to the standard LEY Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s ²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with incremental A/B phase encoder
Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s ²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with absolute batteryless encoder
Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s ²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with absolute batteryless encoder
Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with incremental A/B phase encoder
Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with incremental A/B phase encoder
Body sizes: 16, 25, 32, 40; Stroke range: 50 to 1200mmin 50mm increments; Maximum work load: 75 kg (horizontal); 25 kg (vertical); Maximum speed: 1500 mm/s (H lead, size 25); Maximum acceleration: 10, 000 mm/s² (horizonal); 5,000mm/s² (vertical); Positioning repeatability: ±0.02mm (±0.015mm high precision type); Motor type: 24 VDC step motor with battery-less absolute encoder
Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s ²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with absolute batteryless encoder
I/O and actuator cables are also identical to the standard LEY Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s ²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with incremental A/B phase encoder
Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with incremental A/B phase encoder
Type: 000 (Lever Type Feedback), Pressure Gauge: 0 (None), Construction: 1 (w/Terminal Box), Accessories: E (For Stroke 35 to 100mm w/Lever Unit), Connection: 4 (G1/4, G1/2)
The MPa type displays up to 3 decimal places (.000).
For example, if the pressure is 0.120 MPa, it is displayed as “.120”. Note) Old ITV series regulators display only up to 2 decimal places (.00).
Body ported manifolds are available with bar or separate ty, SUBPLATE NVFS6*000 3/4 NPT, VALVE, VFS6000 SOL VALVE 4/5 PORT, 22, VFS6000, 3.7686 lb