SMC Corporation of America
Elite Part Number Search
Search Results "ISE20A-S-01-JD"

1 Speed Exhaust Controller Series ASV Size: M3, M5, 1/8, 1/4, 3/8 How to Order Integration of a quick exhaust valve and an exhaust restrictor permits high-speed cylinder operation. 3 1 0 F 01 06 ASV S K Speed exhaust controller Option Nil None The effective area is two times larger.

DC(+) 5 OUT1 4 OUT2 3 FUNC 2 DC(-) 1 -21No.PS-OMU0008CN-D ZSE20C(F)/ISE20C(H)-S/-R () NPN 2 DC(+) Max.28 V80 mA 1 V R15 V OUT1 1 k S420 mA OUT2 12 V 300 24 V 600 DC(-) 50 DC(+) -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) DC(+) -X () -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) -22No.PS-OMU0008CN-D -V/-T () PNP 2 DC(+) Max.80 mA 1 V T15 V OUT1 1 k V420 mA OUT2

Back Pressure Regulator for General Applications Series BP1000 Operating pressure: 0.5 to 300 psig (0.0034 to 2.1 MPa) Body material: Stainless steel and Brass available Hastelloy internals available for corrosion resistance How to Order Port Number q w e r BP10 01 4PL 4 4 S 0 0 Operating pressure Bonnet option Code pressure 0.5 to 10 psig (0.0034 to 0.07 MPa) 1 to 30 psig (0.007 to 0.2 MPa

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: D (Panel Mount Adapter + Front Protection Cover)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N7H (ø1/4" One-touch Fitting, Straight Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: D (Panel Mount Adapter + Front

Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N7H (ø1/4" One-touch Fitting, Straight Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: D (Panel Mount Adapter + Front Protection

Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: D (Panel Mount Adapter + Front Protection Cover)

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø1/4" One-touch Fitting, Straight Type, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter + Front Protection Cover, Operation

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø1/4" One-touch Fitting, Straight Type, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter + Front Protection Cover, Operation

Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: -

Bit line Bit Details 7 6 5 4 3 2 1 0 Time base Multiplier Bit 0 to 5: Multiplier (0 to 1) Bit 6 to 7: time base (00, 01, 10) Calculation condition Time base Time base value Calculation Cycle time 00 0.1 ms Multiplier x Time base 0.4 ms to 6.3 ms 01 0.4 ms 6.4 ms + multiplier x Time base 6.4 ms to 31.6 ms 10 1.6 ms 32.0 ms + multiplier x Time base 32.0 ms to 132.8 ms -78No.EX-OMZ0024 Data

Alarm Code.01 to 21,24,25,28,29,32: Eliminate the error cause. Press the [RESET] key on the operation display panel or power cycle the main breaker to enable error recovery to take effect. *Alarm code 02 and 16 are alarms only for HRZ008-L/L1-F. *Alarm code 28 is an alarm only for HRZ010-W*S-F.

HRW008-H, -H*S HRW015-H, -H*S HRW030-H, -H*S: 6 LOW FLOW 0, 850LPM 0, 2.113.2GPM 7 FLOW UNIT LPM, GPM Allows the selection of the unit of flow rate. 8 PRESS UNIT MPa, PSI Allows the selection of the unit of pressure. 9 SLAVE ADRS. 1 to 16CH Allows the selection of the slave address for serial RS-485 communication. Allows the selection of alarm signals for contact signal.

(AC24V) Bdy potted vKF300.11A.1 (With bracket) M5) (Manifold only) ,_Without subplate 01T 1/s NPTF subplate Indicator light / Surge voltage suppressor 'S With surge voltage supprdssor 7 With indicalor light and surge voltage suppressor (D type only) " Special order * Z oplion is not available wilh grommel. ' Special ofcler Construction / Parts List Symbol . .rf--rF t / V \ I ] \ N L I T I

(AC24V) Bdy potted vKF300.11A.1 (With bracket) M5) (Manifold only) ,_Without subplate 01T 1/s NPTF subplate Indicator light / Surge voltage suppressor 'S With surge voltage supprdssor 7 With indicalor light and surge voltage suppressor (D type only) " Special order * Z oplion is not available wilh grommel. ' Special ofcler Construction / Parts List Symbol . .rf--rF t / V \ I ] \ N L I T I

The programmed Key(s) will give an output signal for as long as the key is depressed.

"-"()7 D Digit () 1 digit=0.01 MPa 0.01 MPa 0.01,0.02,,0.99,1.00 F 01[MPa] F.S.=1-0=1[MPa] (1F.S.=10.01=0.01[MPa]) F.S.

Optional Parts Clean Room Compliant (10-) 10-ARP20(K) 10-ARP30(K) 10-ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut ARP20P-260S ARP30P-260S ARP40P-260S G49-4-01 G49-4-02 0.4 MPa G49-2-01 G49-2-02 0.2 MPa Round type Note 2) G49-7-01 G49-7-02 0.7 MPa Pressure gauge NPN output / Wiring bottom entry ISE35-N-25-MLA [ISE35-N-25-M (Switch body only)] NPN output

370 440 100 120 130 160 180 210 246 290 ITVX 1 4, 3 8, 1 2 1 4, 3 8, 1 2 1 2, 3 4 1 2, 3 4 PVQ 3 4, 1 3 4, 1 VY1 Adapter Assembly Installation Procedure Accessory/Compact Pressure Switch: IS10-01 For details, refer to Best Pneumatics No. 8.