(Variable) 3% F .S. or less (Fixed) 1 to 10% of set prss. (Variable) 1 to 10% of set press. (Adjustable) Hysteresis Data ON: when output is ON (Red) ON: when output is ON (Red) ON: when output is ON (OUT1: Red, OUT2: Green) Indicator light Trimmer adjustment 3 turns 200 degrees 3 turns 200 degrees 3 turns 200 degrees None 1 to 5 V 5% F .S.
How to order I Z S 3 0 7 8 0 S B I Z S 3 0 D 1 I Z S 3 0 C S I Z S 3 0 B E I Z S 3 0 N T Ionizer Bracket Product name I Z S 3 0 Bar type Ionizer B Mounted Not mounted For "mounted", two brackets for body end are attached. Number of attached bracket for body middle part is by the bar length.
16.5 + Stroke 23 + Stroke 29 + Stroke Rod end male thread Rod end nut / Accessory (Option) Rod end nut S X W V U Q R T (mm) (mm) Rod end male thread Applicable bore size V W X U R S T Q Part no.
70 N 11 18 18.5 20 26 ZZ 103 132 137 156 182 NA 17 24 30 36 46 R 28 34 40 50 S 83 106 111 124 150 W 35 50 50 50 60 X 19 25 30 40 40 Model 12-CY3B15 12-CY3B20 12-CY3B25 12-CY3B32 12-CY3B40 P (Piping port) Model Mounting nuts (2 pcs.) are shipped together.
Then, the charge time (T) for a 10 L tank: T = t x = 3.2 x = 32 (s). V 10 T = t x = 89 x = 89 (s).
Switches P: Operating pressure (PSI) V: Speed (inch/s) Stroke (inch) Mode of operation (horizontal, inclined, vertical) Mode of operation Note 1) Inclined operation Vertical operation Horizontal operation Review of load weight and operating pressure W Lo Guide First tentative bore size determination F1 D 1.6 x P First tentative bore size determination F2 D 1.6 x P First tentative bore size
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-12 Connection of RS-232C 3.3 Installation HRR Series 3-20 HRX-OM-X071 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
for 2 hrs. each (De-energized) 980 m/s 2 in X, Y, Z directions, 3 times each (De-energized) 3% F .S. or less 1000 VAC for 1 min.
Manifold Specifications For internal pilot Type 20 Type 41,S41 Type 42,S42 Type For external pilot Type 20R Type 42R,S42R Single base type /B mount Manifold type Common SUP, Common EXH P(SUP), R(EXH) type 2 to 20 stations Valve stations Valve Base Location A port specifications Top Side Direction M5 0.8 1/8 NPTF M5 0.8 1/8 NPTF P,R port M5 0.8 Port size M3 0.5 A port M3 0.5 N3T (5/32" one-touch
READ DOWN STOP 105.5 M5 x 0.8 x 5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (Sensor pressure port) External sensor type 123 100.5 70 M3 x 0.5 x 9.5 48 6 (Sensor breathing port) PRESSURE OUT CONTOROLLER RUN 4 3 2 1 CH kPa 4 3 2 1 SW D-IN RUN UP SET P-ON READ
1.3 x 10-10 P.526 XVD2-02S 522 Smooth Vent Valve (Supply Line) XVD Series RoHS How to Order 02 XVD 2 V Fitting type Smooth vent valve V S For VCR For Swagelok Space-saving Valve / needle valve integrated construction requires only 1/4 the piping space of previous models.
Subsonic flow at P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P (P2 + 0.1013) Sonic flow of P1 + 0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min (ANR)] S: Effective area [mm2] P: Amount of pressure drop P1 P2 [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Cylinder stroke (st/mm) Applicable area Unapplicable area Outlet pressure (MPa) Outlet pressure
IDX-OM-W014-C / Series IDU3E-10(-C,K,L,M,R,S,T) IDU3E-20(-C,K,L,M,R,T) IDU4E-10(-C,K,L,M,R,S,T) IDU4E-20(-C,K,L,M,R,T) IDU6E-10(-C,K,L,M,R,S,T) IDU6E-20(-C,K,L,M,R,T) IDU3E-23(-C,K,L,R,T,V) IDU4E-23(-C,K,L,R,T,V) IDU6E-23(-C,K,L,R,T,V) URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC ISO4414 * 1) JIS B8370 *2 ) *1) ISO 4414
Tightness of Valve (Leak rate) Fluid Seal material Non-leak, Vacuum V, M (2) 106Pam3 /s Note 1) Differs depending on the operating conditions such as pressure, etc. Note 2) Value on option V, M (Non-leak, Vacuum). Air Liquid Port P Port A 1 cm3/min or less NBR, FKM, EPDM 0.1 cm3/min or less(1) Normally open (N.O.)
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-9 Connection of RS-232C 3.3 Installation HRR Series 3-18 HRX-OM-X084 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-13 Connection of RS-232C HRS Series 3.3 Installation 3-27 DOC1001322 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.
IDX-OM-W022-A PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDU8E-10(-C,K,L,M,R,S,T) IDU8E-20(-C,K,L,M,R,T) IDU11E-10(-C,K,L,M,R,S,T) IDU11E-20(-C,K,L,M,R,T) IDU15E1-10(-C,K,L,M,R,S,T) IDU15E1-20(-C,K,L,M,R,T) IDU8E-23(-C,K,L,R,T,V) IDU11E-23(-C,K,L,R,T,V) IDU15E1-23(-C,K,L,R,T,V) Please read this manual prior of using the air dryer. Keep the manual readily available for reference.
A 24 VK M5 thread 8 deep, with or without insert depending on base material. VZ 32 VF A' VFR Coding stud.
For subsonic range Where P1 + 0.1013 = (1 to 2) (P2 + 0.1013) Formula based on Cv factor Q = 197.8Cv P (P2 + 0.1013) kg/h Formula based on effective area Q = 11.0S P (P2 + 0.1013) kg/h [650] (133) 0.2 [646] (120) 0.1 S = 2.8mm S = 5.9mm S = 9.2mm S = 11.7mm S = 6.3mm S = 9.7mm S = 14.4mm S = 10.8mm S = 15.3mm S = 24.8mm Flow rate Q kg/h VCS212 VCS213 VCS214 VCS215 VCS 13 VCS314 VCS315
IDX-OM-W013-C PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDU3E-10(-C,K,L,M,R,S,T) IDU3E-20(-C,K,L,M,R,T) IDU4E-10(-C,K,L,M,R,S,T) IDU4E-20(-C,K,L,M,R,T) IDU6E-10(-C,K,L,M,R,S,T) IDU6E-20(-C,K,L,M,R,T) IDU3E-23(-C,K,L,R,T,V) IDU4E-23(-C,K,L,R,T,V) IDU6E-23(-C,K,L,R,T,V) This manual is intended to explain the installation and operation of the product.