SMC Corporation of America
Elite Part Number Search
Search Results "JJ5SY1-10S60-12F-C6"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, NEW SY5000 MFLD, UJ, NEW SY5000 MFLD, FITTING 2.85278 lb, 2.85278 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MANIFOLD, VALVE, NEW SY5000 MFLD, WP, NEW SY5000 MFLD, FITTING >1/4, 2.85307 lb

SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone

SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone

SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone

SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone

Main Body Shape: One-Touch Fitting Type, Number of Ports: 2-Port, Number of Switching Positions: 2-Position Normally Closed, Switching Operation: Knob, Effective Sectional Area(mm2): 12.92, Effective Sectional Area Class(mm2): Up to 15, Pipe Port Type: One-Touch Plumbing, Plumbing Thread Nominal: -, Connecting Tube Diameter: Ø12, Mounting Method: Side, Plumbing Type

Main Body Shape: One-Touch Fitting Type, Number of Ports: 3-Port, Number of Switching Positions: 2-Position Normally Closed, Switching Operation: Knob, Effective Sectional Area(mm2): 12.92, Effective Sectional Area Class(mm2): Up to 15, Pipe Port Type: One-Touch Plumbing, Plumbing Thread Nominal: -, Connecting Tube Diameter: Ø12, Mounting Method: Side, Plumbing Type

Main Body Shape: One-Touch Fitting Type, Number of Ports: 2-Port, Number of Switching Positions: 2-Position Normally Closed, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 12.92, Effective Sectional Area Class(mm2): Up to 15, Pipe Port Type: One-Touch Plumbing, Plumbing Thread Nominal: -, Connecting Tube Diameter: Ø12, Mounting Method: Side, Plumbing

Main Body Shape: One-Touch Fitting Type, Number of Ports: 3-Port, Number of Switching Positions: 2-Position Exhaust, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 12.92, Effective Sectional Area Class(mm2): Up to 15, Pipe Port Type: One-Touch Plumbing, Plumbing Thread Nominal: -, Connecting Tube Diameter: Ø12, Mounting Method: Side, Plumbing Type

Size: 2 Port Valve, Type: Flame Resistant, P Side Port Size: Ø12, A Side Port Size: Ø12, Knob Color: -, Bracket: -, Cover: -

Series: JSY1000, Type: Side-Ported, Serial Interface, EX260, SI Unit: w/o SI Unit, SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 12 Stations, P,E Port Entry: Both Sides, 2 to 16 Stations, SUP/EXH Block: Internal Pilot, Built-in Silencer, A,B Port Size: ø6 One-touch Fitting

Series: JSY1000, Type: Side-Ported, Serial Interface, EX260, SI Unit: w/o SI Unit, SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 16 Stations, P,E Port Entry: Both Sides, 2 to 16 Stations, SUP/EXH Block: Internal Pilot, Built-in Silencer, A,B Port Size: ø6 One-touch Fitting

Series: 1 (JSY1000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: 0 (w/o SI Unit), SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 12 Stations, P,E Port Entry: B (Both Sides, 2 to 16 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting)

Series: 1 (JSY1000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: 0 (w/o SI Unit), SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 16 Stations, P,E Port Entry: B (Both Sides, 2 to 16 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting)

DN (EtherCAT, Comm: M8 2pc, Pwr: M8 2pc), Valve Stations: 10 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), Number of Pressure Sensors: 4 (4 Stations), Pressure Detection Port for Non Pilot Control Sensor Blocks: A (Built-in Pressure Sensor, A Port: Fitting, B Port: Plug), Pilot Air Control Block: None, A,B Port Size: C6

DN (EtherCAT, Comm: M8 2pc, Pwr: M8 2pc), Valve Stations: 5 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), Number of Pressure Sensors: 2 (2 Stations), Pressure Detection Port for Non Pilot Control Sensor Blocks: A (Built-in Pressure Sensor, A Port: Fitting, B Port: Plug), Pilot Air Control Block: None, A,B Port Size: C6

SI Unit: DN (EtherCAT, Comm: M8 2pc, Pwr: M8 2pc), Valve Stations: 6 Stations, P,E Port Location: U (U Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, Number of Pressure Sensors: 1 (1 Station), Pressure Detection Port for Non Pilot Control Sensor Blocks: None (in case of Pilot Air Control Only), Pilot Air Control Block: X (X Pilot Air Control Block, at station 1), A,B Port Size: C6