(L) M typ plug connector (M) World Wide QS\E Support...
R R: Gripping point distance [mm] 6 MHL2 Series Construction 10 16 to 25 e r t u w y @4 @0 @1 @2 !7 !5 !8 @3 !3 e o i q @6 @7 @3 @5 !9 !0 !2 !1 !6 !4 Component Parts No. Description Material Note 1 Body Aluminum alloy Hard anodized No.
I = I + IA kgm (m to m : Mass of I to I kg) D Calculation example When d1 = 0.1m, d = 0.05m, D = 0.04m, a = 0.04m, b = 0.02m m = 1kg, m = 0.4kg, m = 0.5kg, m = 0.2kg, Gear tooth ratio = 2 Cylinder: I I = 0.2 x = 0.03 x 10 -3kg m I = 1 x = 1.25 x 10 -3 kgm 0.1 8 0.04+0.02 12 b IB = (0.13 + 0.1 + 0.03) x 10 -3= 0.26 x 10 -3 kgm 0.05 8 I = 0.4 x = 0.13 x 10 -3 kgm a IA = 2 x 0.26 x 10 -3 = 1.04
For EE (ZSE4E) 24 V 12 V 6 V 5 V 3 V 5 6 V S R Lead wire length 0.5 (2.9) m NPN output Analog output PNP output 27 26 67 Lead wire length 0.5 (2.9) m Lead wire length 0.5 (2.9) m Not required for Nil, vacuum adapter (GN) and vacuum pressure gauge (G).
Example: Cylinder diameter: 50 mm Stroke: 600 mm Working pressure: 0.5 MPa Cycles: 5 per minute Bore size: 6 mm Piping length (between the cylinder and the valve): 2 m 6.Extend the intersection point 1 upward to a 6 piping bore size. Intersection point 2 is obtained. 7.Extend the intersection point 2 rightward or leftward.
6 Parts list Parts list Note Material No. Description No.
2 35.8 36 Blue A 40 5 1 UNIT 12 to 24 VDC Series PF2D5 RESET SET PF2D300-A(-M) Panel fitting dimensions 3 x 7.2 (=21.6) 8-M3 36 +0.5 0 6.4 OUT2 NC Sensor 8 Load 4 OUT1 Black Main circuit 1 2 3 4 7 3 Load +0.5 0 Brown + 6 2 19.4 Blue 5 1 12 to 24 VDC 5 6 7 8 Series PF2D5 PF2D301-A(-M) The applicable panel thickness is 1 to 3.2 mm.
Refer to pages 5-11-2 to 6 for Safety Instruction and Solenoid Valve Precautions.
The minimum unit of the travel distance of the actuator should be 1 [m]. It is necessary to set it on the PLC side according to the kind of PLC. 35 - 6.3 The recommended value of the parameter [LEY] LEY25/ LEYG25 LEY25D/ LEYG25D LEY32/LEYG32 LEY32D/ LEYG32D Series Lead symbol A B C A B C A B C A B C Lead 12 6 3 12 6 3 20 10 5 16 8 4 Parameter *1,*2 Para.
Part no. m t Snap ring D d9 3 d l D d9 3 L d l m t Snap ring L IY-P006 CT-P006 0.65 0.020 0.045 0.020 0.045 17.6 20.4 Clip type C3 Clip type C3 0.65 9 2.85 2.85 6 0.75 0.75 6.2 Data IY-P010 CT-P010 5 5 0.7 0.030 0.060 0.030 0.060 20.5 23.9 Type C 5 Type C 5 0.7 13.6 4.8 4.8 10 10 1 1 10.2 IY-P015 CT-P015 6 6 0.8 0.030 0.060 0.030 0.060 28.1 31.7 Type C 6 Type C 6 0.8 15.8 5.7 5.7 15 15 1
Part no. m t Snap ring D d9 3 D d9 3 d l L d l m t Snap ring L IY-P006 CT-P006 0.65 0.020 0.045 0.020 0.045 17.6 20.4 Clip type C3 Clip type C3 0.65 9 2.85 2.85 6 0.75 0.75 6.2 Data IY-P010 CT-P010 5 5 0.7 0.030 0.060 0.030 0.060 20.5 23.9 Type C 5 Type C 5 0.7 13.6 4.8 4.8 10 10 1 1 10.2 IY-P015 CT-P015 6 6 0.8 0.030 0.060 0.030 0.060 28.1 31.7 Type C 6 Type C 6 0.8 15.8 5.7 5.7 15 15 1
Theoretical Output (N) Operating pressure (MPa) Rod diameter (mm) Piston area (mm) Operating direction Model 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.15 39.2 33.6 28.0 22.4 16.8 8.4 11.2 56 OUT M L 4 CXS 6 21.7 18.6 15.5 12.4 9.3 4.6 6.2 31 IN 110 94.2 78.5 62.8 47.1 31.4 157 OUT 15.7 M L 6 CXS 10 70.0 60.0 50.0 40.0 30.0 20.0 100 IN 10.0 247 212 177 141 106 70.6 353 OUT 35.3 M L 8 CXS 15 176 151
The minimum unit of the travel distance of the actuator should be 1 [m]. It is necessary to set it on the PLC side according to the kind of PLC. 38 - 6.3 The recommended value of the parameter [LEY] LEY25/ LEYG25 LEY25D/ LEYG25D LEY32/LEYG32 LEY32D/ LEYG32D Series Lead symbol A B C A B C A B C A B C Lead 12 6 3 12 6 3 20 10 5 16 8 4 Initial value Recommended value Parameter *1,*2 Para.
5 CYP32 (Nm) M1 M2 M1 0.3 3 M2 0.6 4 M3 0.3 3 Model CYP15 CYP32 m m Static moment Moment generated by the work piece weight even when the cylinder is stopped M Pich moment M1 = m x g x (L + B) x 103 M Yaw moment M3 = m x g x (L + A) x 103 M Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance
5 CYP32 (Nm) M1 M2 M1 0.3 3 M2 0.6 4 M3 0.3 3 Model CYP15 CYP32 m m Static moment Moment generated by the work piece weight even when the cylinder is stopped M Pich moment M1 = m x g x (L + B) x 103 M Yaw moment M3 = m x g x (L + A) x 103 M Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance
M H2 (Hex.) L2 L1 Thread R(PT) Part No.
2 @6 t @4 w @8 r !1 @5 @3 @2 e !6 A A C B M(D)LUB25 y !9 i o !5 @0 Extension locking w q Section A-A !
Cable core wire colors Brown White Blue Black Green/Yellow 1 2 3 4 5 Connections 19 Accessories EX600-W Series u Power Supply Cable with M12 Connector (B-coded) SPEEDCON PCA1564927 Socket specification, Cable length (L) 1564927 Straight 2 m 1564930 Straight 6 m 1564943 Angle 2 m 1564969 Angle 6 m Straight connector type Angle connector type 50 L 36.3 14.8 50 L 44.5 2 1 5 2 1 5 28 5.9 M12
, dust, and oil have been removed is specified Atmospheric pressure dew point 17C Pneumatic measuring instruments (Air micrometers) Drying and cleaning 0.01 m 0.1 mg/m3 (ANR) 1, 4, 2 Mist Separator Micro Mist Separator Oil odor to Series AMH Series IDG Series AMD + + No.6 Rotary screw air compressor Pressure dew point 10C Micro Mist Separator with Prefilter Membrane Air Dryer 1, 6, 2 Mist
Maximum load mass m 1 = m/mmax = 1/5 = 0.20 L2 Review m. L1 M2 = m g (L1 + B) 103 2. Static moment m x g = 1 9.8 (50 + 48) 103 Review M2. Since M1 & M3 are not generated, review is unnecessary. = 0.96 [Nm] 2 = M2/M2 max = 0.96/4 = 0.24 M Guide shaft mounting surface L1 B We = 5 x 103 m g U = 5 x 103 1 9.8 300 = 14.7 [N] Me3 = 1/3 We (L2 + A) 103 3.