Connector type Lead wire length: 3 m CL Nil Y Standard type (1 W for DC) Note) DC low wattage type (0.5 W) Connector type Without connector CN Note) In the case of the manifold type or when single unit valves are aligned closely with each other, avoid energization lasting more than 3 days.
(Use an auto switch rated 24V DC, with a minimum amperage capacity of 10mA.) q q q w w w e e e r (Unit: N) Bore size (mm) 40 50 63 80 100 Operation r Min. sensing weight 26 40 62 100 160 Warning Back-up of the balance pressure data The balance pressure data is backed up by the controller for approximately 5 minutes during a power outage or when the power supply has been turned OFF.
3 Sleeve 7 Iron Spacer 8 PBT r Return spring 9 Stainless steel w Board assembly 10 e Casing 11 PBT q Plug 12 NBR O-ring 13 NBR 3 Diaphragm Type Direct Acting 2/3 Port Solenoid Valve for Chemicals Series LVM10/100 Construction/Base Mounted Type LVM13R LVM14R LVM16R !2 !0 !2 !0 !2 !0 !1 !1 !1 y y y t t t u u i i u i o o !3 !3 o !3 r r r e e w w e w q !4 !4 q q !4 LVM115 Description No.
Tilt the screwdriver down in direction q so that the clip slides out in direction w. Seal part no.
3 Sleeve 7 Iron Spacer 8 PBT r Return spring 9 Stainless steel w Board assembly 10 e Casing 11 PBT q Plug 12 NBR O-ring 13 NBR 3 Diaphragm Type Direct Acting 2/3 Port Solenoid Valve for Chemicals Series LVM10/100 Construction/Base Mounted Type LVM13R LVM14R LVM16R !2 !0 !2 !0 !2 !0 !1 !1 !1 y y y t t t u u i i u i o o !3 !3 o !3 r r r e e w w e w q !4 !4 q q !4 LVM115 Description No.
Cylinder speed < Counting speed of the counter (Cylinder speed 500 mm/sec = Counting speed of the counter 5 kcps) RS Q G RS H A RZQ MI W S Example of Recommended Pneumatic CEP1 Horizontal mounting Vertical flat mounting Vertical overhead mounting CE1 W W CE2 ML2B C J G5-S CV MVGQ Note) In the case of light load, regulate head side supply pressure.
(Put packing B w on the surface contacting to the end plate.) (11 stations) 4 stations (12 stations) 5 stations 3. For a style with a D-sub connector, open the cover !4 and insert the pin of lead wire assembly !0 as shown in the right figure.
M2 bolt circle M1 W I dia.
(With light: 1.2 W), 100 VAC: 1.4 W (1.45 W), 110 VAC: 1.45 W (1.5 W) Air Operated Valve Specifications Refer to page 13-4-11 for dimensions.
TB W Counter bore depth TC Inner cover holding screw Note) (mm) E 4 6 J M6 x 1 M10 x 1.5 LD 5.6 9.2 L 67 90 K 21 20 JK 10 12 HP 44 73.5 HL 37.6 63.3 HI 23 39 HA 23 39 H 45 75 G 10 9 F 12.5 25 EK 4 6 ED 9.5 13 C 6.4 10.2 B 10.5 16 A 8 12 Model CYV15 CYV32 +0.030 H9 0 +0.030 H9 0 Z 132 165 Y 2.5 3.5 W 69 115 TC 0.5 0.5 TB 15 22 TA 20 22.5 T 30 34 R 45 79.5 QW 48 83 Q 112 147 PC 10 12 PB 60
1 3 Port Solenoid Valve Series V100 V100 Power Consumption 0.1 W (With power saving circuit) Power Consumption 0.1 W (With power saving circuit) Power Consumption 0.1 W (With power saving circuit) SY SYJ VK VZ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VT VP
TB W Counter bore depth TC Inner cover holding screw Note) (mm) E 4 6 J M6 x 1 M10 x 1.5 LD 5.6 9.2 L 67 90 K 21 20 JK 10 12 HP 44 73.5 HL 37.6 63.3 HI 23 39 HA 23 39 H 45 75 G 10 9 F 12.5 25 EK 4 6 ED 9.5 13 C 6.4 10.2 B 10.5 16 A 8 12 Model CYV15 CYV32 +0.030 H9 0 +0.030 H9 0 Z 132 165 Y 2.5 3.5 W 69 115 TC 0.5 0.5 TB 15 22 TA 20 22.5 T 30 34 R 45 79.5 QW 48 83 Q 112 147 PC 10 12 PB 60
W Axial Right F R L T B Cable length Left Top 2m 3m 4m 5m 2 3 4 5 Motor specification Standard motor Matsushita Electric Industrial Co., Ltd.
Example: Set 20 W (100 W 20%) for the 100-W external Regenerative resistor with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur . 2.
N.O. q IFW50--75/76 e Color of lead wire Black Symbol Contact q w Power supply (Common) w Red Terminal (Relay terminal) 24 VDC Gray e Power supply (Light terminal) N.O. N.C. q IFW50--85/86 e Color of lead wire Black Symbol Contact q w Power supply (Common) White Terminal (Relay terminal) w 24 VDC Gray e Power supply (Light terminal) N.C. N.O.
TB W Counterbore depth TC Inner cover holding screw Note) (mm) E 4 6 J M6 x 1 M10 x 1.5 LD 5.6 9.2 L 67 90 K 21 20 JK 10 12 HP 44 73.5 HL 37.6 63.3 HI 23 39 HA 23 39 H 45 75 G 10 9 F 12.5 25 EK 4 6 ED 9.5 13 C 6.4 10.2 B 10.5 16 A 8 12 Model CYV15 CYV32 +0.030 H9 0 +0.030 H9 0 Z 132 165 Y 2.5 3.5 W 69 115 TC 0.5 0.5 TB 15 22 TA 20 22.5 T 30 34 R 45 79.5 QW 48 83 Q 112 147 PC 10 12 PB 60 100
22.0 30.0 W 9.5 4.0 4.0 1.5 W 7.5 2.0 2.0 0.5 W 3.5 (6) 2.0 (0.5) 2.0 (0.5) 4.5 (2) A 12.5 11.0 18.0 26.0 B 3.5 4.0 6.5 Note 1) Negative figures in the table W indicate that an auto switch is mounted inward from the edge of the cylinder body.
Unrestricted 300/50 m/s2 Lubrication Mounting orientation Impact/Vibration resistance Enclosure(2) Dustproof Grommet (G), DIN terminal (D) 100, 110, 200, 220, 240 V 6, 12, 24, 48 V 10% of rated voltage 9.5 VA/50 Hz, 8 VA/60 Hz 7 VA/50 Hz, 5 VA/60 Hz 3.5 VA/50 Hz, 3.3 VA/60 Hz 3 VA/50 Hz, 2.8 VA/60 Hz 4 W (Standard), 2 W (Low power consumption type) 4.3 W (Standard), 2.3 W (Low power consumption
W-rth std. gauge. An individualSUP spacer on manifold block can form individual P oort for the valve. ffi I NWFgTOOO| NWF9+oOOtP-{)0T-1 P-ff]T-2 %% Nore) Fd prssr|e center Vpe valves, use p/n NAFBF3000.
(Values at the initial period) Solenoid Specifications VT325-G V100 S070 Symbol VQD (A)2 VQD-V Grommet, Conduit, DIN terminal, Conduit terminal 100, 200 VAC, 50/60 Hz, 24 VDC 15 to +10% of rated voltage 75 VA 60 VA 27 VA 17 VA 12 W Electrical entry VK Coil rated voltage Allowable voltage fluctuation (R)3 1(P) VT VT 50 Hz 60 Hz 50 Hz 60 Hz Inrush AC Apparent power (3) Holding DC Power consumption